SOP: Counting Yeast and Mould with 3M Petrifilm Yeast and Mold Plates (MFHPB-32)

GIFSQ ID: SOP-0956

Yeast and mould counts track spoilage potential and process hygiene, but conventional fungal plates tie up media preparation and incubator space for days. Petrifilm Yeast and Mold (YM) plates arrive ready to use: nutrients, antibiotics and a cold-water-soluble gelling agent are already coated on the film, together with 5-bromo-4-chloro-3-indolyl phosphate (BCIP), an indicator of phosphatase activity that makes growth easier to see. One millilitre goes on, the gel sets, and the plate incubates on the bench.

Reading separates the two groups by eye. Yeasts form small, defined blue-green or off-white colonies; moulds grow larger and more diffuse, usually blue but often showing their natural pigmentation in black, yellow or green. Collaborative work has compared this format extensively against conventional methods.

Purpose

Enumerate yeasts and moulds in food products and food ingredients without preparing agar media, gaining the labour and time savings of a ready-to-use film plate while keeping a count that stands comparison with conventional fungal enumeration.

Scope

Apply this SOP to food products and food ingredients. Petrifilm plates may also serve environmental sampling under the laboratory procedures for environmental monitoring. Diluent choice is restricted: citrate buffer and sodium thiosulfate must not be used with Petrifilm plates. Where a standard calls for citrate buffer, substitute Butterfield’s phosphate buffer warmed to 40 to 45°C.

Equipment and Materials

  • 3M Petrifilm Yeast and Mold Count plates, 6407/6417 (3M Canada Inc.), stored at or below 8°C
  • Plastic spreading device supplied with the plates, used concave side down
  • Package insert with instructions for use; the manufacturer’s Interpretation Guide is available on request
  • Diluents: Butterfield’s phosphate buffer, 0.1% peptone water, or distilled water
  • Stomacher, blender or equivalent
  • Bench space or incubator holding 20 to 25°C
  • Colony counter and/or magnified illuminator
  • Pipette or plate-loop continuous pipetting syringe for 1 mL additions

Procedure

  1. Hold samples refrigerated (2 to 8°C) or frozen before analysis, according to the product; shelf-stable foods are excepted. Thaw frozen samples in a refrigerator or under conditions that prevent growth or death, and analyse as soon as possible after receipt.
  2. Have sterile diluent ready and disinfect the work surface. Set the Petrifilm plate on a flat surface and mark the identifying sample information on the film.
  3. Build a representative analytical unit: mix liquids until homogeneous, and for solids take representative portions from several locations within the sample. Prepare a 1:10 dilution in a suitable diluent from the list above and mix thoroughly.
  4. Lift the top film and inoculate 1 mL of sample or diluted sample carefully onto the centre of the bottom film, using a pipette or a plate-loop continuous pipetting syringe.
  5. Drop the top film down onto the sample.
  6. Spread the sample evenly by pressing down on the centre of the plastic spreader, concave side down. Never slide the spreader across the film. Leave the plate undisturbed for at least 1 minute so the gel can solidify; the sample spreads over the 30 cm² growth area.
  7. Return unused plates to the foil pouch, seal it by folding and taping the open end, and store the resealed pouch in a cool dry place. Use opened plates within one month. Exposure above 24°C and/or to humidity above 50% RH can damage plate performance; discard plates showing orange or brown discolouration. Note the expiry date and lot number on the package; the lot number also appears on each film.
  8. Incubate the plates horizontally, clear side up, in stacks of no more than 20. Follow current standards for incubation temperature (working conditions 20 to 25°C) and look for growth at both 3 days and 5 days.
  9. Count promptly after the incubation period. When counting cannot happen at once, plates may be stored in the freezer, though that should not become routine practice.
  10. Count with a standard colony counter; a magnifier-illuminator helps with small yeast colonies. Colonies can be lifted for further identification by raising the top film and picking the colony from the gel.

Recording Results

Calculate yeasts and moulds per mL or g from the colonies on plates at dilution levels giving a statistically significant result, counting yeasts and moulds separately using the appearance rules in the introduction. On duplicate plates of consecutive dilutions, first work out the mean number of colonies for each dilution, then determine the average count.

Crowded plates are estimated by area. Growth area is a circle of approximately 30 cm². On a plate carrying more than 150 colonies, count one or more representative squares, average the count per square, and multiply by 30 for the total per plate. Where very high yeast numbers turn the whole growth area blue, or heavy mould growth turns it blue, black or yellow, the plate is beyond counting: dilute the sample further and repeat.

Quality Control

Plate condition is the control point for this format. Store unopened plates at or below 8°C, use opened pouches within one month, and reject any plate with orange or brown discolouration. Check expiry and lot information on every package. Incubation temperature control follows the standing tolerances: at the lower incubation temperatures used here (30 or 25°C and below), ± 1.0°C applies. Keep the package insert and Interpretation Guide with the bench copy of this SOP, and remember that 3M Microbiology production for these plates is certified to ISO 9001, which supports, but does not replace, in-laboratory checks with known material.

Troubleshooting

  • Whole growth area turned blue: yeast numbers are too high to count; prepare a further dilution and replate instead of estimating.
  • Growth area black or yellow overall: heavy mould growth has overrun the plate; dilute further and repeat.
  • Uneven or off-centre spread: the spreader was slid or the plate was moved before the gel set; press straight down, concave side down, and leave the plate a full minute undisturbed.
  • Plates underperforming across a pouch: check storage history: heat above 24°C or humidity above 50% RH after opening, a pouch older than one month, or discoloured films all explain failure.
  • Colonies hard to see: use the magnifier-illuminator and rely on the BCIP indicator colour; yeast colonies stay small and defined, so scan the whole 30 cm² area systematically.
  • Counting delayed: freeze the plates rather than leaving them at room temperature, and count as soon as practicable.

Interferences and Limitations

Diluent chemistry matters: citrate buffer and sodium thiosulfate are prohibited with Petrifilm plates, and citrate-buffer steps in other standards must be swapped for warmed (40 to 45°C) Butterfield’s phosphate buffer. Mould pigmentation varies naturally, so colour alone never separates mould from yeast; colony size and diffuse versus defined edges carry the distinction. Plates above roughly 150 colonies support estimates only, and saturated plates support no count at all. Performance depends on film condition, so heat, humidity and age damage results silently if storage rules are ignored.

Safety Notes

  • Handle mould plates with care: avoid opening heavily grown plates more than needed for counting or picking, and never sniff a plate; mould spores are respiratory irritants and allergens.
  • Treat all food homogenates as potentially infectious and dispose of used plates as microbiological waste.
  • Disinfect benches before and after work, and wash hands after handling cultures.
  • Use blenders and stomachers with lids and bags secured before starting.

Source Method

This SOP is an original-wording adaptation of Health Canada method MFHPB-32, Enumeration of Yeast and Mould in Food Products and Food Ingredients Using 3M Petrifilm Yeast and Mold Count Plates, issued March 2003 in Volume 2 of the Compendium of Analytical Methods.