SOP: Counting Total Aerobic Bacteria with 3M Petrifilm Aerobic Count Plates (MFHPB-33)

GIFSQ ID: SOP-0957

Aerobic count is the workhorse hygiene number in a food laboratory, and Petrifilm Aerobic Count (AC) plates deliver it without a single agar pour. Dry medium and a cold-water-soluble gelling agent sit coated on the film; a 1 mL portion goes on, a spreader flattens it over the growth area, and after incubation every colony shows red, thanks to 2,3,5-triphenyltetrazolium chloride (TTC) in the modified Standard Methods nutrients. Reduction of TTC is what colours the colonies, which makes counting fast and consistent.

Small handling details decide whether the number is trustworthy. Bubbles in the gel or a non-circular inoculation area distort the count, pH outside 6.6 to 7.2 suppresses recovery, and certain diluents are barred outright. This SOP keeps those controls in the procedure where they belong.

Purpose

Enumerate total aerobic bacteria in food products and food ingredients for checking compliance with Sections 4 and 7 of the Food and Drugs Act and other relevant federal regulations, using a ready-to-use film plate in place of a conventional pour or spread plate.

Scope

Apply this SOP to food products and food ingredients. Environmental sampling with the same plates is covered by the environmental sampling laboratory procedure. Diluent restrictions are hard rules here: never use diluents containing citrate, bisulfite or thiosulfate with Petrifilm plates. For cheese work where citrate buffer is specified, substitute Butterfield’s phosphate buffer warmed to 40 to 45°C.

Equipment and Materials

  • 3M Petrifilm Aerobic Count plates, 6400/6406 (3M Canada Inc.), stored under refrigeration
  • Plastic spreading device supplied with the plates, used concave side down
  • Product instructions and the manufacturer’s Interpretation Guide (available online from 3M)
  • Diluents: Butterfield’s phosphate buffer (IDF phosphate buffer, 0.0425 g/L KH2PO4 adjusted to pH 7.2), peptone salt diluent (ISO 6887), buffered peptone water (ISO 6579), 0.1% peptone water, saline (0.85 to 0.90%), bisulfite-free Letheen broth, or distilled water
  • Stomacher, blender or equivalent
  • Incubator holding 35°C
  • pH meter or paper reading to 0.3 to 0.5 pH units across pH 6.0 to 7.5
  • NaOH 1N or HCl 1N for pH adjustment
  • Colony counter and/or magnified illuminator (optional)

Procedure

  1. Hold sample units refrigerated or frozen before analysis, according to the product; shelf-stable foods are excepted. Thaw frozen units in a refrigerator or under conditions that prevent growth or death, and analyse as soon as possible after receipt.
  2. Have sterile diluent ready, disinfect the work surface, and set the Petrifilm plate on a flat, level surface.
  3. Build a representative analytical unit: mix liquids or free-flowing materials until homogeneous, and for solids take portions from several locations within the sample unit.
  4. Prepare a 1 in 10 (1:9) dilution in a suitable diluent from the list above. Stomach or blend as needed for thorough mixing.
  5. Adjust the pH of the diluted sample to 6.6 to 7.2 with 1N NaOH or 1N HCl.
  6. Lift the top film and inoculate 1 mL of sample or diluted sample carefully onto the centre of the bottom film. Use a pipette, pipettor or equivalent, held perpendicular to the film.
  7. Release the top film and let it drop onto the sample. Do not roll the top film down.
  8. Set the plastic spreader over the film with its concave face downward and press firmly at its centre so the inoculum spreads evenly. Lift it straight off again rather than dragging it across the surface. Then leave the plate alone for a minute or more while the gel sets; a good plate shows an even circle covering the 20 cm² growth area. Any plate with trapped bubbles or a ragged, non-circular area gets discarded and remade, because it cannot be counted reliably.
  9. Return unused plates to the foil pouch and seal the pouch to exclude air. Store the resealed pouch in a cool dry place and use the plates within one month of opening. Keep plates away from temperatures above 25°C and relative humidity above 50%; both harm performance. Reject discoloured plates and respect the expiry date carried in the lot number on each package.
  10. Incubate at 35 ± 1°C, plates horizontal with the clear side up, in stacks of no more than 20, for up to 48 ± 3 hours.
  11. Count promptly after incubation. When counting cannot happen within 1 hour of removal from the incubator, plates may be held in a sealable container, frozen at −15°C or colder, for no longer than one week; avoid making that a routine practice.
  12. Count with a colony counter and/or magnified illuminator where that helps. Colonies can be picked for further identification by lifting the top film and taking the colony from the gel.

Recording Results

Count every red dot as a colony, whatever its size or intensity. Calculate colonies per mL or g from plates at dilution levels giving a statistically significant result, meaning 25 to 250 colonies. When no plate falls in that window, plates carrying 1 to 25 colonies may be used. With duplicate plates of consecutive dilutions, only plates inside the significant range feed the average.

Overloaded plates are estimated by area: growth area is approximately 20 cm², so count one or more representative squares, average the colonies per 1 cm² square, and multiply by 20 for the total per plate; this estimation route applies above 250 colonies. Two outcomes are recorded as too numerous to count (TNTC): a growth area turned entirely red or pink by very high colony concentrations, and an overcrowded plate whose centre looks empty while many small colonies ring the edges. Both need a further dilution for a reportable number. Distinguish true colonies from opaque food particles, which are not counted. Where a gel-liquefying organism has spread and hidden other colonies, estimate from the unaffected squares only and do not count colonies inside the liquefied area.

Quality Control

Incubator performance is verified, not assumed: 35 ± 1°C for this method’s incubation, and tighter ± 0.5°C control wherever higher temperatures such as 43 or 45.5°C are specified in other methods on the same unit, because of lethality risk. Film condition checks (storage temperature, pouch sealing, one-month use window, no discolouration, in-date lots) form the media quality gate, and any variation in media formulation carries an equivalency obligation for the laboratory. Work should meet ISO/IEC 17025 general requirements. Keep the manufacturer’s Interpretation Guide with the bench copy; it governs fine points of colony appearance.

Troubleshooting

  • Bubbles or a ragged, non-circular inoculation area: discard the plate and remake it; such plates cannot be counted accurately. Hold the pipette perpendicular and let the top film drop rather than rolling it.
  • Centre of the plate looks empty but edges are crowded: classic overcrowding; record TNTC and repeat at a higher dilution.
  • Counts suspiciously low on acidic foods: check the pH step; diluted samples must sit between 6.6 and 7.2 before inoculation.
  • Colonies smeared or merged: suspect a gel-liquefying organism; estimate from unaffected squares and note the interference on the record.
  • Opaque specks mistaken for colonies: food particles stay opaque and do not take the red TTC colour; count red dots only.
  • Whole pouch reading poorly: review storage: exposure above 25°C or humidity above 50%, a pouch open longer than one month, or expired or discoloured plates.

Interferences and Limitations

Prohibited diluents are the first limit: citrate, bisulfite and thiosulfate all interfere with Petrifilm chemistry, and only bisulfite-free Letheen broth is acceptable in that family. Gel liquefiers obscure neighbours and force estimated counts. Food particles can mimic colonies to an untrained eye. Counts above 250 per plate are estimates, and plates read as TNTC carry no number at all until a higher dilution is run. Freezing counted plates is a short holding measure (one week at −15°C or colder), not a storage method.

Safety Notes

  • Treat all food homogenates and incubated plates as potentially infectious; dispose of used plates as microbiological waste.
  • Handle 1N NaOH and 1N HCl with gloves and eye protection during pH adjustment.
  • Secure blender lids and stomacher bags before starting, and open blended samples away from the face.
  • Disinfect benches before and after each batch and wash hands on leaving the bench.

Source Method

This SOP is an original-wording adaptation of Health Canada method MFHPB-33, Enumeration of Total Aerobic Bacteria in Food Products and Food Ingredients Using 3M Petrifilm Aerobic Count Plates, issued April 2015 in Volume 2 of the Compendium of Analytical Methods.