SOP: Texture Profile Analysis by Penetrometer
GIFSQ ID: SOP-1071
Texture decides whether a spread scoops cleanly, a sausage bites firm, or a gel holds its shape on the spoon. This SOP runs a texture profile analysis (TPA) using a penetrometer-style probe on a texture testing instrument: two compression cycles that mimic chewing, from which hardness, cohesiveness, springiness, chewiness and adhesiveness are calculated. The classic two-bite method originates with Bourne (1978), and sensory TPA vocabulary follows ISO 11036:2020.
Purpose
To run a texture profile analysis (TPA) using a penetrometer-style probe on a texture testing instrument, and to report hardness, cohesiveness, springiness, chewiness and adhesiveness for solid and semi-solid foods.
Scope
Applies to solid and semi-solid foods: gels, processed meats, baked goods, confectionery, spreads, and dairy products such as cheese and processed cheese. Not suitable for thin liquids, granular products, or highly heterogeneous samples where a single probe reading cannot represent the product.
Equipment and Materials
- Texture analyzer or motorized penetrometer with calibrated load cell (5 to 50 kg range, accuracy plus or minus 0.5 percent of full scale)
- Cylindrical probe: 36 mm diameter flat-ended cylinder (or 75 mm compression platen for large samples)
- Calibration weight set, traceable to national standards
- Digital caliper, plus or minus 0.01 mm
- Sample rings or molds producing uniform specimens (for example 25 mm diameter by 20 mm height)
- Thermometer with 0.1 C resolution
- Temperature-controlled water bath or incubator
- Distilled water and mild detergent for probe cleaning
Procedure
- Bring samples to the defined test temperature: 20 C plus or minus 2 C for ambient products, or the product’s serving temperature for refrigerated goods (typically 4 C plus or minus 1 C). Condition for at least 2 hours.
- Cut or mold specimens to uniform dimensions: 25 mm diameter and 20 mm height. Measure each specimen and reject any deviating more than 0.5 mm from the target.
- Verify the load cell calibration with the check weight. Zero the force reading with the probe in air.
- Center the specimen on the base plate directly beneath the probe.
- Set test parameters: pre-test speed 1.0 mm/s, test speed 1.0 mm/s, post-test speed 10 mm/s; trigger force 5 g; target compression 50 percent of specimen height; hold time between cycles 5 seconds.
- Start the cycle. The probe compresses the specimen twice, with a 5-second pause between the two bites.
- Record the force-time curve. Read from it: hardness equals peak force of the first compression (N); cohesiveness equals area under the second curve divided by area under the first curve (dimensionless); springiness equals height recovered after the first compression divided by original compression distance (dimensionless); chewiness equals hardness times cohesiveness times springiness (N); adhesiveness equals negative force area on the first withdrawal (N·s).
- Clean the probe between specimens so residue does not carry over.
- Test a minimum of 10 replicate specimens per sample. Discard replicates where the probe struck the edge or the specimen fractured asymmetrically, and replace them.
Calculation and Reporting
Report the mean and standard deviation of hardness, cohesiveness, springiness, chewiness and adhesiveness across the 10 replicates. Express hardness and chewiness in newtons (N). Acceptance criterion: the relative standard deviation (RSD) of hardness must not exceed 10 percent; if it does, examine the batch for heterogeneity and test a second set. Include test temperature, probe diameter, compression percentage and instrument serial number in the report.
Safety
- Keep hands clear of the probe during travel; the instrument applies enough force to crush a finger. Lock the drive before changing probes.
- Chilled samples are biological materials: wear gloves and follow the site’s food-contact hygiene rules.
Quality Control
- Verify load cell calibration with the check weight before each test session and re-zero with the probe in air.
- Work in batches of five specimens and return the rest to temperature control: hardness values drifting downward across replicates usually mean the specimens are warming on the bench.
- Reject and replace replicates where the probe struck the edge or the specimen fractured asymmetrically.
- Accept the set only when the RSD of hardness does not exceed 10 percent; otherwise examine the batch for heterogeneity and test a second set.
Records
Keep the worksheet for each batch: sample ID, test temperature, probe diameter, compression percentage, instrument serial number, the force-time curve file reference, the 10 replicate results with mean and standard deviation, and the analyst name and date.
References
- Bourne, M. C. (1978), two-bite texture profile method (as cited on the page).
- ISO 11036:2020, sensory analysis, vocabulary for texture profile (as cited on the page).
- ISO/IEC 17025:2017, General requirements for the competence of testing and calibration laboratories (laboratory quality system).
Next step: for TPA on the General Foods Texturometer, see the GIFSQ SOP on texture profile analysis using the General Foods Texturometer.