SOP: Specific Migration of Individual Substances (EN 13130 Approach)
GIFSQ ID: SOP-0966
Overall migration weighs everything that leaves a plastic. Specific migration asks a narrower, harder question: how much of one named substance, a monomer, an additive or a starting substance, reaches food or a food simulant? Health risk lives at that level. Each restricted substance carries its own specific migration limit, derived from toxicology, and compliance means showing that one substance, measured with a method selective enough to see it among everything else that migrated, stays below its own limit.
Exposure arithmetic behind the limits is deliberately conservative. Regulation assumes a person of 60 kg body weight eats 1 kg of food per day, packed in contact with 6 dm2 of packaging, and that the food always contains the substance at the limit concentration. An acceptable or tolerable daily intake, in mg per kg body weight per day, multiplied through that convention gives the limit in food: in general terms, an SML value results from the ADI or TDI value and a factor of 60.
Purpose
Purpose is to determine the specific migration of an individual authorised substance from a plastic material or article into food or a food simulant, following the EN 13130 approach, and to judge the measured value against the specific migration limit for that substance in EU Regulation 10/2011.
Scope
Scope covers substances on the Union list of authorised monomers, other starting substances and additives in Annex I of EU Regulation 10/2011. Roughly 900 substances appear on that list in the source account, and currently approximately 440 of them are regulated by specific migration limits. Only listed substances may intentionally be used in plastic layers. Where determination of specific migration is difficult or impossible because a substance is chemically unstable or highly volatile, a maximum residual content applies instead, and the residual-content SOP governs. Substances behind a functional barrier, non-intentionally added substances and screening work sit outside the compliance run described here.
Equipment and Materials
- Migration cells, pouches, immersion vessels or the finished article, selected as for overall migration, so that only the food-contact side is exposed where the design requires it
- Temperature-controlled equipment able to hold the selected contact time and temperature for the full exposure
- Food simulants A to E as listed in the overall migration SOP: ethanol 10% (v/v), acetic acid 3% (w/v), ethanol 20% (v/v), ethanol 50% (v/v), vegetable oil, and MPPO (Tenax) for dry foods
- Gas chromatograph with flame ionisation or mass spectrometric detection, with headspace, solid-phase microextraction or purge-and-trap sampling for volatiles, as the analyte requires
- Liquid chromatograph with diode array, fluorescence or mass spectrometric detection for non-volatile analytes
- Reference substance for the target analyte, calibration standards prepared in simulant or extract, and internal standard where the analyte method calls for one
- Sample preparation equipment suited to the simulant, including clean-up for fatty simulants where analysis in oil would otherwise fail
Procedure
- Identify the target and its limit before any bench work. Confirm the substance is on the Union list, note its specific migration limit, and note any group limit that sums several substances. Limits in the source range from around the analytical detection limit, approximately 10 µg of substance per kg of food or food simulant, up to the lower ppm range of 1 to 30 mg/kg. If no specific value is given in the Union list, the specific migration limit is 60 mg/kg food.
- Choose food or simulant. Migration may be measured in a food that has already been in contact with the packaging, or in food simulants after migration contact. Pick the simulant by the assignment rules in the overall migration SOP: hydrophilic foods take simulants A, B or C, with B where pH is below 4.5 and C for alcoholic foods up to 20% plus foods made more lipophilic by organic ingredients; lipophilic foods take D1 for alcohol above 20% and oil-in-water emulsions, D2 where free fat sits at the surface; dry foods take simulant E. Remember that a result obtained in food prevails over a result obtained in a simulant under Article 19 of EU Regulation 10/2011.
- Fix worst-case contact conditions. Expose specimen to simulant under the worst foreseeable contact conditions for the intended application, for both time and temperature. For contact beyond 30 days apply the long-term conditions stated in the overall migration SOP, including 10 days at 60°C for storage over six months at room temperature and below, 10 days at 50°C for storage up to six months at room temperature, and 10 days at 40°C for refrigerated and frozen storage, each including heating up to 70°C for up to 2 hours or up to 100°C for up to 15 minutes. Keep the specimen physically unchanged at the test temperature; the phase transition temperature of the polymer sets the ceiling.
- Run the migration contact. Bring the defined area of material into contact with a defined quantity of simulant, hold for the full period, then separate and retain the simulant for analysis. Run a simulant blank through identical conditions alongside.
- Select the analytical finish by substance class. Use the mapping in the table below, drawn from the source guidelines table. Volatility and molecular weight, not habit, decide the instrument.
| Type of substance | Examples | Predominant analytical method |
|---|---|---|
| Volatiles, boiling point below 150°C | Monomers, residual solvents | Headspace, solid-phase microextraction, or purge and trap, with gas chromatography and FID or MS detection |
| Semivolatiles, boiling point below 300°C, molecular weight below 400–500 Da | Plasticisers, glycols, additives | Liquid injection (split, splitless, programmed temperature vaporising, on-column) with gas chromatography and FID or MS detection |
| Non-volatiles, molecular weight above 400–500 Da | Antioxidants, additives | Liquid chromatography with diode array, fluorescence or MS detection |
- Follow the substance-specific standard where one exists. Work to the applicable part of the EN 13130 series. Part 1 is the guide to test methods for specific migration, determination of substances in plastics, and selection of exposure conditions. Substance parts include, among others: Part 2, terephthalic acid in food simulants; Part 3, acrylonitrile in food and food simulants; Part 5, vinylidene chloride in food simulants; Part 7, monoethylene glycol and diethylene glycol in food simulants; Part 9, acetic acid vinyl ester in food simulants; Part 10, acrylamide in food simulants; Part 11, 11-aminoundecanoic acid in food simulants; Part 12, 1,3-benzenedimethanamine in food simulants; Part 13, 2,2-bis(4-hydroxyphenyl)propane (bisphenol A) in food simulants; Part 15, 1,3-butadiene in food simulants; Part 16, caprolactam salt in food simulants; Part 18, dihydroxybenzenes, 4,4′-dihydroxybenzophenone and 4,4′-dihydroxybiphenyl in food simulants; Part 19, dimethylaminoethanol in food simulants; Part 21, ethylenediamine and hexamethylenediamine in food simulants; Part 23, formaldehyde and hexamethylenetetramine in food simulants; Part 24, maleic acid and maleic anhydride in food simulants; Part 25, 4-methyl-1-pentene in food simulants; Part 26, 1-octene and tetrahydrofuran in food simulants; Part 27, 2,4,6-triamino-1,3,5-triazine in food simulants; and Part 28, 1,1,1-trimethylolpropane in food simulants.
- Quantify against calibration in the same matrix. Prepare calibration standards in blank simulant or blank extract, correct for the blank run in step 4, and confirm the method can see well below the limit, since many limits sit near 10 µg/kg. Where no CEN part exists, use a validated method from the scientific literature or a method collected by the European Commission Joint Research Centre from European Food Safety Authority petition work, and record its identity.
- Consider a screening route only to prove compliance. Permitted screening approaches include replacing specific migration by overall migration for non-volatile substances, determining residual content and calculating total transfer, migration modelling, and substitute simulants. Each must be at least as severe as the conventional test. A screening failure never proves non-compliance; only a conventional migration test can do that, and a failed screen goes forward to one.
- Judge the result. Compare the blank-corrected concentration in food or simulant, expressed as mg per kg, with the substance limit from step 1, applying any group summation first.
Recording Results
Report specific migration in mg of substance per kg of food or food simulant, naming the substance, the limit applied, the simulant or food, contact time and temperature, contact area and simulant quantity, the analytical technique and its detection limit, and the blank value. State plainly whether the figure came from a conventional migration test or from a screening approach, because the two carry different weight: screening can establish compliance, while non-compliance can be stated only from migration testing into food or food simulants.
Quality Control
Run the simulant blank with every exposure set, plus spike recovery checks in the same simulant matrix, particularly for vegetable oil, where the complex matrix is the usual cause of analytical failure. Verify calibration linearity across the limit value, not merely across a convenient range. Cross-check borderline results on a second detection principle where the EN 13130 part allows it, for example MS confirmation alongside FID quantification. Interlaboratory comparison underpins several CEN methods in this series, so outlying laboratory bias should trigger method review rather than result averaging.
Troubleshooting
- Analyte lost or unstable in simulant: chemical instability is a known reason specific migration cannot be determined for some substances; switch to the residual-content route rather than reporting a falsely low migration.
- Fatty simulant defeats the chromatography: improve clean-up of the oil extract, or move to a permitted substitute simulant approach, confirming first that the substitute overestimates migration.
- Volatile analyte reads low: check for loss during contact and transfer; use sealed headspace sampling and minimise open handling, as general practice for volatiles.
- Result just above the limit from a screen: do not report non-compliance; run the conventional migration test, which alone can support that conclusion.
Interferences and Limitations
Co-migrating substances can overlap a target peak in a crowded extract, so selectivity must be demonstrated, not presumed. Partitioning matters as well: a non-polar substance in a polyolefin may barely enter an aqueous simulant, giving a low result that reflects solubility rather than absence from the material; residual-content data or modelling can expose that gap. Sensory failure can occur well below a health-based limit for some substances, as the source notes for acetaldehyde in carbonated water, so a chemical pass is not a complete quality verdict.
Safety Notes
- Handle ethanol simulants, chromatography solvents and headspace vials under pressure with the precautions on their safety data sheets, as general laboratory practice.
- Treat monomers and reference substances as hazardous until their data sheets prove otherwise; weigh and dilute them in a fume hood.
- Take care with hot migration cells and with glassware removed from ovens at the higher contact temperatures.
- Dispose of simulant extracts and calibration waste through the chemical waste route.
Source and Standard
Source and standard: drafted from Chapter 11, section 11.3.7 and related definitions in sections 11.2.5 and 11.3.1 to 11.3.5, of Singh, Wani and Langowski (eds.), Food Packaging Materials: Testing and Quality Assurance (CRC Press, 2017). Governing documents cited by number are EU Regulation 10/2011, European Framework Regulation 1935/2004, and the EN 13130 and CEN/TS 13130 series for substances subject to limitation in plastics.