SOP: Measuring Sediment in Milk from Individual Cans with the Off-the-Bottom Tester (MFO-8)
GIFSQ ID: SOP-0961
Sediment tells a plain story about how milk was handled before it reached the plant: dirt, debris and other visible matter settle to the bottom of a can, and a test that samples anywhere else can miss them entirely. Sampling right off the bottom is therefore the defining feature of this method, from insertion of the tester through to the stroke that pulls milk across the can floor.
Simplicity should not be mistaken for looseness. A fixed volume is drawn in on one upstroke, pushed through a standard filter disc on the downstroke, and the disc is then graded against standard discs or photographs that express sediment in milligrams. Keeping tester, disc size and stroke pattern the same every time is what makes one can’s result comparable with another’s.
Purpose
Purpose here is to determine sediment in milk: to filter a definite quantity of milk through a standard filter disc using a standard type pump, called the tester, and then to determine the character and amount of residue retained on that disc.
Scope
Scope is milk, tested in accordance with Section B.08.024 of the Food and Drug Regulations. Design intent matters when choosing where to use the method: the off-the-bottom procedure is designed for sampling milk from individual farmers’ milk cans, as distinct from bulk milk tanks. Equipment description and considerations for the off-the-bottom procedure are those given for that procedure in Standard Methods for the Examination of Dairy Products, American Public Health Association, 11th edition, 1960, and those considerations apply to this method. Results are graded per disc, for the 16 fl oz (450 ml) quantity drawn by the tester.
Equipment and Materials
- Standard off-the-bottom tester, single-unit type, taking in 16 fl oz (450 ml) on the upstroke of the piston (plunger) and discharging through the filter disc on the downstroke
- Standard lintine filter discs, diameter 1 1/8 inches (2.86 cm)
- Photographs of discs containing standard amounts of sediment, expressed in milligrams per 16 fl oz (450 ml)
- Or, instead of photographs, standard discs prepared as defined in Standard Methods for the Examination of Dairy Products, American Public Health Association, 11th edition (1960), pages 257–260
- Still, matte-surfaced white paper or cardboard for mounting discs, or transparent envelopes designed for that purpose
- Milk cans to be sampled, presented so the tester can reach the bottom of each can
Procedure
- Fit a clean disc. Insert a standard lintine filter disc into a clean tester, seating it so milk discharged on the downstroke must pass through the disc.
- Reach the bottom. Insert the tester down to the bottom of the can to be sampled.
- Draw the sample across the bottom. Pull the plunger upwards to draw in the sample, 16 fl oz (450 ml) on the upstroke, keeping the intake surface of the tester within 1/4 inch (0.63 cm) of the bottom of the can while moving the tester once diametrically across the bottom of the can. Where the bottom of the can is not flat, move the tester around the circumference instead.
- Discharge through the disc. Discharge the milk with a complete downstroke of the plunger, so the full drawn quantity passes through the filter disc and any sediment is retained on it.
- Clear the tester. Remove the tester from the can. Draw the plunger upwards 6 to 8 inches (15 to 20 cm) and quickly push the plunger downwards as far as it will go.
- Recover the disc. Remove the disc from the tester, handling it so retained residue is not disturbed, and mount it on still, matte-surfaced white paper or cardboard, or insert it into a transparent envelope designed for the purpose.
- Grade the disc. Compare the disc with the standard discs or photographs of discs, noting both the amount of sediment and its character, and record the result as set out below. Repeat from step 1 for each further can, starting each time with a clean tester and a fresh disc.
Recording Results
Record the identity of the can sampled, the amount of sediment found by comparison with the standard discs or photographs, expressed in milligrams per 16 fl oz (450 ml), the quantity drawn by the tester, and a note on the character of the residue retained on the disc. A satisfactory disc is one that does not contain more than 2 mg of sediment. Discs are kept mounted on their white paper or cardboard, or in their transparent envelopes, so the graded result can be re-examined later; record the grading alongside the mounted disc it belongs to, following your laboratory’s normal record practice.
Quality Control
Comparison standards anchor every grading, so work only with the photographs of discs containing standard amounts of sediment, or with standard discs prepared as defined in Standard Methods for the Examination of Dairy Products, 11th edition (1960), pages 257–260. A clean tester and a fresh standard disc for each can prevent carry-over from a heavily sedimented can inflating the next result, a matter of ordinary laboratory care, stated here because the method’s comparability depends on it. Volume control is built into the equipment: the single-unit tester takes in 16 fl oz (450 ml) on the upstroke, and a complete downstroke is what discharges that quantity through the disc, so a partial stroke is a failed test rather than a smaller sample.
Troubleshooting
- Disc shows heavy sediment only in one patch: check tester movement during sampling; the intake must travel once across the bottom, diametrically, or around the circumference where the bottom is not flat, rather than sitting in one spot.
- Suspected low result on a can expected to be dirty: verify the intake stayed within 1/4 inch (0.63 cm) of the bottom for the whole draw; sediment settles, and an intake riding higher samples cleaner milk.
- Discharge looks incomplete: repeat with a fresh disc after confirming the downstroke was complete; a partial downstroke leaves part of the drawn quantity unfiltered.
- Grading is hard to call against the standards: remount the disc flat on still, matte white paper or cardboard, or in its transparent envelope, and compare again in the same viewing conditions used for the standard discs or photographs.
- Residue disturbed when the disc was removed: the grading no longer represents the can; repeat the test on a fresh disc rather than estimating.
Interferences and Limitations
Residue character matters alongside amount: grading records what the residue looks like as well as how much of it the disc retained, because both are part of the determination. Applicability has a clear boundary, sampling is designed for individual farmers’ milk cans, not bulk tanks, and results from a can should not be presented as characterising bulk milk. Because the tester gathers milk along the bottom, technique dominates accuracy: intake height above the bottom, path of travel, and completeness of both strokes each change what reaches the disc. Finally, grading is comparative, not gravimetric: amounts are read against photographs or prepared standard discs, so precision is limited to what that comparison can distinguish.
Safety Notes
- Clean and dry the tester between cans and handle milk residues promptly: spilled milk makes floors and handles slippery, as general laboratory and dairy practice.
- Lift and move full milk cans with suitable assistance or handling aids rather than by hand alone where they are heavy, as general workplace practice; the method itself sets no weight limit.
- Wash hands after handling raw milk and used filter discs, and keep used discs away from food-contact surfaces, as general hygiene practice.
Source Method
Source method is Health Canada Official Method MFO-8, Determination of Sediments in Milk, issued November 30, 1981, in Volume 1 of the Compendium of Analytical Methods.