SOP: Measuring Aerobic Colony Counts in Foods (MFHPB-18)

GIFSQ ID: SOP-0944

An aerobic colony count gives a broad picture of viable aerobic bacteria in a food: how clean production was, how storage has treated a product, and whether numbers sit anywhere near a specification. Analysts choose a temperature aimed at psychrophilic, mesophilic or thermophilic organisms, pour sample dilutions into plate count agar, and count colonies that develop.

Simplicity is deceptive here. Dilution choice, pouring speed and counting discipline decide whether a result means anything, so each sample unit gets handled on its own and every count follows the same selection and rounding rules.

Purpose

Purpose is to estimate viable aerobic bacteria per gram or millilitre across foods, using incubation matched to the organisms of interest: psychrophilic organisms grow optimally at or below 15°C with an upper limit of 20°C and a lower limit of 0°C or below; mesophilic organisms have optima between 20°C and 45°C; thermophilic organisms have optima above 45°C.

Scope

Scope covers foods generally, with each sample unit analysed individually. Except for shelf-stable foods, keep units refrigerated or frozen by product type, thaw frozen units in a refrigerator or under conditions preventing growth or death, and analyse as soon as possible after receipt.

Equipment and Materials

  • Plate count agar (PCA); 0.1% peptone water diluent; 2% sodium citrate pre-warmed to 45°C, for cheese only
  • 0.1% 2,3,5-triphenyltetrazolium chloride, optional, for separating colonies from food particles
  • Stomacher, blender or equivalent; water bath at 45°C for tempering agar; incubator able to hold the chosen growth temperature; colony counting device optional
  • Sterile Petri plates, pipettes and dilution bottles

Procedure

  1. Decide first which group is being enumerated: psychrophilic, mesophilic and/or thermophilic. Set incubator and counting expectations around that choice before any dilution is made.
  2. Prepare plate count agar, dispense in suitable quantities and sterilise by manufacturer directions. Temper molten agar in a 45°C water bath with the water level 1 cm above the medium level in bottles.
  3. Disinfect working surfaces. Mark duplicate plates clearly for each sample and dilution.
  4. Make dilutions in sterile 0.1% peptone water, except cheese, which goes into 2% sodium citrate pre-warmed to 45°C. Liquids such as milk and water may be pipetted directly and/or into diluent with shaking; viscous liquids are weighed into diluent and shaken; water-soluble solids and spices are weighed into diluent and shaken; powders, meats and shellfish are weighed into diluent and blended or stomached; cheese is weighed into warmed citrate and blended or stomached.
  5. Build a representative unit: stir liquids and free-flowing materials to homogeneity, and for solids take portions from several locations. Prepare a 1 in 10 dilution by blending or shaking 25 g or mL into 225 mL diluent. Other unit sizes keep the same ratio, for example 11 g in 99 mL or 10 g in 90 mL.
  6. Limit blending to 2.5 min at most so frictional heat does not injure cells. Foaming foods call for low blender speed and sampling from below the liquid–foam interface. Bottles mixed by hand get shaken 25 times through a 30 cm arc in about 7 seconds.
  7. Prepare further decimal dilutions as needed, using a fresh sterile pipette for every transfer, and shake each dilution immediately before transferring so organisms stay evenly distributed.
  8. Resuspend settled material by agitation, then pipette 1 mL or 0.1 mL of each required dilution into duplicate plates. Products that stick to plate bottoms should be pipetted onto 1.0 mL sterile diluent already placed in the plate.
  9. Pour 12–15 mL tempered agar into each plate and mix by rotating and tilting. Let plates solidify. Pouring must finish within 15 min of dilution preparation.
  10. Invert plates and incubate for 48 ± 4 h at a temperature suited to the target group: suggested ranges are 15–20°C for psychrophilic, 30–40°C for mesophilic and 50–60°C for thermophilic bacteria. Psychrophilic and thermophilic plates may incubate up to 5 days. Other verified time–temperature combinations may be used when a laboratory has proven suitability. Avoid crowding or excessive stacking so plates reach incubator temperature quickly.
  11. Count promptly after incubation ends.

Recording Results

Select plates holding 25–250 colonies, pinpoint colonies included. Counts outside that window may still be used when nothing falls inside it, choosing plates nearest the range and reporting results as estimates, flagged E. Spreading colonies need a workaround: count a representative spreader-free portion and scale by the reciprocal of the fraction counted; 30 colonies on one quarter of a plate, for example, gives 30 × 4 = 120 colonies for the whole plate.

Calculate concentration as total colonies divided by (total volume plated × dilution). Two plates at a 10−1 dilution with 34 and 42 colonies give (34 + 42) / (2 mL × 10−1 g/mL) = 380 CFU/g. When two dilutions both land in range, use a weighted average across all plates: plates with 247 and 238 colonies at 10−1 plus 26 and 25 colonies at 10−2 give [(247 + 238) + (26 + 25)] / [(2 mL × 10−1) + (2 mL × 10−2)] = 2,436 CFU/g. Round every reported count to two significant figures, so 2,436 CFU/g reports as 2,400 CFU/g. Worked reporting patterns at a 1 in 1,000 dilution: an average of 144 colonies reports as 140,000 per g; 440 colonies reports as 440,000 E; 15 colonies reports as 15,000 E; and zero colonies reports as less than 500 per g.

Zero growth needs a less-than value built from a single hypothetical colony on one replicate plate. Two plates seeded with 1 mL undiluted liquid and no colonies give < (1 + 0) / (2 mL × 100 g/mL), that is < 0.5 CFU/g. When the lowest dilution plated was 10−2, the same logic gives < (1 + 0) / (2 mL × 10−2 g/mL), that is < 50 CFU/g.

Quality Control

Media preparation and sterilisation follow manufacturer instructions, and molten agar tempering gets checked before pouring. Duplicate plates should agree reasonably; wide disagreement prompts review of mixing, pipetting and settling before a result is released. Incubation temperature belongs to the validated choice for the target group, and any alternative combination needs documented verification.

Troubleshooting

  • Food particles masquerading as colonies: hold one extra refrigerated plate per dilution as an unincubated comparison control, or flood incubated plates with 2 mL of 0.1% 2,3,5-triphenyltetrazolium chloride, rock to cover, pour off excess and leave inverted at room temperature for 3 h; bacteria reduce the indicator to red formazan and stand out. Colonies cannot be picked for isolation after indicator flooding.
  • Spreaders overrunning plates: count a clean representative area and scale up, reporting an estimate.
  • Counts too high or too low across all plates: extend the dilution series on repeat and report out-of-range counts as estimates rather than discarding them silently.
  • Clumping or settling: re-agitate every dilution immediately before transfer and keep blending within the 2.5-minute ceiling.

Interferences and Limitations

Particles from meat, milk powder and similar matrices mimic colonies and inflate counts without a comparison control or indicator step. Pour-plate heat can under-recover stressed organisms, and a single incubation temperature recovers only organisms suited to it, so an aerobic count never describes total microbial load. Results from plates far outside 25–250 colonies carry estimate status and lower precision.

Safety Notes

  • Handle all foods as potentially carrying pathogens; use standard microbiological hygiene, gloves where local rules require them, and bench disinfection before work.
  • Manage molten agar and 45°C water baths as scald hazards, and allow plates to solidify on level surfaces.
  • Dispose of incubated plates as biohazard waste; never open overgrown or mouldy plates outside appropriate containment.

Source Method

Adapted in original wording from Health Canada method MFHPB-18, Determination of the Aerobic Colony Counts in Foods, September 2020, Compendium of Analytical Methods, Volume 2.