Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

SOP: Finding E. coli O157:H7 and O157:NM in Foods and on Surfaces (MFHPB-10)

GIFSQ ID: SOP-0942

Some strains of Escherichia coli O157 cause severe illness, and routine coliform work will miss them. This procedure isolates O157:H7 together with its non-motile counterpart, O157:NM, from any food and from environmental surface samples such as sponges and swabs. A non-motile strain still carries H7 genes and typical O157 traits, so both forms count as pathogenic O157:H7 for reporting.

Enrichment comes first, followed by antibody-coated magnetic beads that pull O157 cells out of a mixed culture. Plating on two selective agars and a short battery of biochemical and serological checks then separate true O157:H7/NM from look-alikes. Handle every step as a presence-or-absence test: one confirmed isolate makes a sample positive.

Purpose

Purpose here is straightforward: recover viable O157:H7/NM when present, even at low numbers and even when background flora is heavy, and confirm identity with enough tests that a positive result can stand up to review.

Scope

Scope covers all foods and environmental surfaces. Sample units may be tested singly or composited, with a hard ceiling of 325 g per composite. Shelf-stable foods aside, hold units refrigerated or frozen according to product type until analysis, thaw frozen units in a refrigerator or under conditions that neither grow nor kill organisms, and start work as soon as possible after receipt.

Equipment and Materials

  • Modified tryptic soy broth with 20 mg/L novobiocin (mTSB-n); enterohemorrhagic E. coli enrichment broth (EEB) for optional second enrichment
  • Group 1 agars: modified hemorrhagic coli agar (mHC) with tellurite and cefsulodin, mHC with cefixime-tellurite supplement (mHC-CT), BBL CHROMagar for E. coli O157, RAPID’E.coli O157:H7 agar
  • Group 2 agars: modified sorbitol MacConkey with tellurite, cefixime and cefsulodin (TCCSMAC), CT-SMAC, CR-SMAC
  • Trypticase soy agar with yeast extract (TSA-YE), phenol red sorbitol agar with MUG, urea agar slants, purple broth or carbohydrate agar with 1% cellobiose
  • Potassium sulfite (K2SO3), PBS-Tween wash buffer, Gram stain reagents, IMViC reagents, MUG or BCIG reagents, ultraviolet light
  • Dynabeads anti-E. coli O157, magnetic particle concentrator (Dynal MPC-S or equivalent), sample mixer; BeadRetriever automated separator optional
  • O157 antisera and latex agglutination kits for O157; rapid identification system (VITEK 2, API or equivalent); verotoxin or verotoxin-gene detection kits
  • Stomacher, blender or vortex mixer; incubators at 35°C and 42°C; controls: verotoxin-gene carrier O157:H7 (for example ATCC 35150) as positive control and a non-O157 E. coli without vt1/vt2 genes (for example ATCC 25922) as negative control

Procedure

  1. Ready sterile mTSB-n, and EEB when needed, pre-warmed to 35 ± 2°C. Disinfect bench surfaces before starting.
  2. Mix liquids and free-flowing foods until homogeneous. For solids, build each analytical unit from portions taken at several places in the unit. Compositing is allowed for up to five analytical units, never beyond 325 g in total.
  3. Make a 1 in 10 dilution: aseptically add 25 g or mL into 225 mL mTSB-n. Other unit sizes are acceptable at that same ratio, for example 65 g for ground beef, and a 325 g composite goes into 2,925 mL broth. A second primary enrichment started directly in EEB is optional where competing flora is high, during outbreak investigation, or whenever an analyst judges it useful; two separate enrichments then run in parallel.
  4. Blend, stomach or vortex until thoroughly mixed. Spices need special care: add 0.5% K2SO3 to mTSB-n before autoclaving for onion and garlic powder and for heavily spiced products, since garlic in particular suppresses O157. Garlic, garlic-containing foods and other spices may need a 1 in 100 dilution instead.
  5. Set up positive and negative controls alongside samples. Incubate enrichments and controls at 42°C for 22–24 h. Incubated mTSB-n may be held refrigerated for up to 48 h.
  6. Use secondary enrichment in EEB only when a rapid screen has flagged O157 but plating of primary broths failed to isolate it, a situation that often reflects high aerobic counts. Transfer 1 mL of mTSB-n and/or EEB into 9 mL EEB, incubate at 35°C for 18–24 h, and continue without refrigeration. Holding refrigerated mTSB-n and transferring to EEB only once need is confirmed is an acceptable way to delay this step.
  7. Carry out immunomagnetic separation, manual or automated. For manual work: place 1.5 mL tubes in the concentrator without its magnet, resuspend beads until no pellet remains, and dispense 20 µL beads per tube. Add 1 mL pre-enriched sample with a fresh pipette per sample, close tubes, and mix at room temperature for 10 min with gentle continuous agitation. Insert the magnet, invert several times, and allow 3 min for beads to collect. Aspirate supernatant and cap liquid without disturbing beads, remove the magnet, add 1 mL PBS-Tween without touching the tube with the pipette, close and invert to resuspend. Repeat capture and washing twice more, ending with magnet removal.
  8. For automated separation with a BeadRetriever: fit one 5-tube strip per sample. Dispense 10 µL mixed beads into tubes 1 and 2, 500 µL wash buffer into tubes 1 and 2, 1 mL wash buffer into tubes 3 and 4, and 100 µL wash buffer into tube 5. Add 500 µL test sample to tubes 1 and 2, fit sterile tip combs, lock the rack in place, close the door, and run the EPEC/VTEC program with the door shut. Use bead complexes from tube 5 for plating, and discard combs and strips as biohazard waste.
  9. Resuspend bead–bacteria complexes in 100 µL PBS-Tween, mixing by pipetting up and down.
  10. Streak 50 µL of suspension onto each of two different agars: either one mHC-type agar plus one chromogenic agar from Group 1, or one Group 1 agar plus one Group 2 agar. Spread across half the plate with a sterile swab to break up complexes, then streak with a loop, carrying the loop back into the previous quadrant several times so beads reach fresh agar.
  11. Incubate and read each agar on its own terms. mHC and mHC-CT: 18–24 h at 42°C; typical O157 colonies do not ferment sorbitol and appear blue, while sorbitol fermenters are yellow. CHROMagar: 18–24 h at 35°C; typical colonies are mauve on a white background, other Gram-negative organisms colourless, blue, green or blue-green. RAPID’E.coli O157:H7: 24 ± 2 h at 37 ± 1°C; typical colonies are dark blue to black, convex, 1–2 mm; atypical β-glucuronidase-positive O157 also appears dark blue to black, and atypical sorbitol fermenters appear blue to turquoise. TCCSMAC: 18–24 h at 42°C; CT-SMAC and CR-SMAC: 18–24 h at 35°C; on all three, typical colonies are translucent and colourless or straw-edged with a darker grey-to-pink centre, while sorbitol fermenters are red.
  12. Move to confirmation with controls in every assay. Where colonies are well isolated and large enough, carry forward at least 10 colonies when available; optional O157 serology may screen at this point, with only O157-positive colonies continued. Poorly isolated or small colonies should first be streaked to selective agar and/or TSA-YE for purity.
  13. Grid two of the chosen agars and inoculate at least 10 typical isolated colonies across grid cells, incubating at the time and temperature proper to each agar. In parallel, inoculate purple broth or carbohydrate agar containing 1% cellobiose and incubate at 35°C for 18–24 h; typical O157 stays purple, meaning cellobiose-negative.
  14. Confirm isolates as E. coli with a rapid identification system, and continue analysis regardless of that result. Confirm O157 with latex agglutination or O157 antisera. Latex and antisera work better after resuscitation in M broth or motility agar repeated at least three times when an isolate is reluctant to agglutinate.
  15. Test for verotoxin or verotoxin genes. A toxin test alone is not enough when negative: a negative toxin result must be followed by gene testing. A negative gene result means the isolate is negative for O157:H7/NM; a positive result by either route confirms the sample.
  16. Add optional checks only when identification is difficult: Gram stain (negative rods expected); MUG/BCIG testing (typical O157 gives no fluorescence and stays pale, most other E. coli fluoresce and turn blue to purple; run BCIG on sorbitol MacConkey with BCIG at 35°C for 22–24 h, or check MUG on phenol red sorbitol agar with MUG, in LST-MUG broth, or with MUG disks on a TSA lawn, all at 35°C for 22–24 h under UV at 345 nm with controls); IMViC plus urea slants at 35°C for 22–24 h (typical pattern: indole positive with occasional indole-negative strains, methyl red positive, Voges-Proskauer negative, citrate negative, urea negative); and H7 agglutination or validated H7 genetic testing.

Recording Results

Report a sample as confirmed E. coli O157:H7/NM when an isolate shows typical reactions across all mandatory confirmation steps. Where H7 testing was performed, report E. coli O157:H7 or E. coli O157:NM accordingly. A presumptive screen positive with no typical isolate after plating calls for secondary enrichment before any negative report. Record which two agars were used, enrichment route, number of colonies carried forward, and each confirmation outcome, so a reviewer can retrace the decision without guessing.

Quality Control

Positive and negative controls run with every batch and every assay, and each control must give its expected reaction before sample results are accepted. Incubator discipline matters: a stated 35°C allows 35 ± 1.0°C, and 30°C or 25°C steps allow ± 1.0°C, but higher selective temperatures must be held within 0.5°C because excess heat can kill stressed target cells. Any substitute bead, medium or concentration step needs validation and equivalency evidence before routine use.

Troubleshooting

  • Screen positive, nothing isolated: run secondary enrichment in EEB from retained refrigerated mTSB-n and repeat separation and plating.
  • Heavy background growth: favour a second primary enrichment in EEB, verify novobiocin and selective supplements were added correctly, and spread beads thoroughly with a swab before loop streaking.
  • Weak serology: resuscitate isolates in M broth or motility agar at least three times and retest.
  • Spice samples repeatedly negative with poor control recovery: check K2SO3 addition and consider the 1 in 100 dilution allowed for garlic and strongly antimicrobial spices.

Interferences and Limitations

High competing flora can mask O157 on plates even after bead capture. Sorbitol-fermenting and β-glucuronidase-positive variants break the classic colony picture, so colour alone never confirms or excludes an isolate. MUG fluorescence also fails as an absolute rule: O157:H16 and H45 strains can fluoresce. Confirmation therefore rests on combined identification, O157 serology and verotoxin evidence, not on any single plate appearance.

Safety Notes

  • Treat O157:H7/NM cultures as infectious material; work with gloves, eye protection and standard enteric-pathogen precautions, and decontaminate benches before and after work.
  • Avoid cross-contamination during separation: fresh pipettes per sample, no pipette contact with wash buffer or tube walls, and careful aspiration that leaves bead pellets intact.
  • Dispose of beads, tip combs, strips and enrichment cultures as biohazard waste. Keep automated separator doors closed during runs.

Source Method