SOP: Determination of Colour of Sugar

GIFSQ — Global Institute for Food Safety & Quality

Principle

The colouring matter in sugar is measured by its absorption at 420 nm in a spectrophotometer against a distilled-water reference of zero colour. Earlier procedures based on the difference between the spectral absorption curves of colouring matter and turbidity at two wavelengths were not entirely successful; the ICUMSA and the ISI procedures, which differ slightly in procedural details, both involve measurement of colour at 420 nm.

Apparatus required

  • Spectrophotometer
  • Absorption cells (cell length chosen to give a reading between 10 and 90% transmittancy)
  • Sintered-glass funnel of porosity F (pores of 0.45 µm) with suction (ICUMSA method)
  • Filter paper (for dark solutions, ICUMSA method)
  • Centrifuge (ISI method)
  • 50-ml volumetric flask (ISI method)

Reagents

a. Distilled water (reference standard of zero colour).

b. Filter aid such as Super-cel, Celite or Kieselguhr at 1% on solids content (for dark solutions, ICUMSA method).

Procedure — ICUMSA method

Prepare a solution of white sugar of 50% solids (for darker sugar, prepare a solution of as high a concentration as possible, consistent with a reasonable filtration rate and cell depths)

↓

Filter the white sugar solution and light-coloured liquors through a sintered-glass funnel of porosity F (pores of 0.45 µm) under suction, without adding filter aid; for dark solutions, add a filter aid (such as Super-cel, Celite or Kieselguhr) at 1% on solids content and filter under suction using a filter paper; discard the first portion of the filtrate if cloudy

↓

Measure the colour at 420 nm in a spectrophotometer using distilled water as the reference standard of zero colour, with a cell length that gives a reading between 10 and 90% transmittancy

Calculation — ICUMSA method

Colour = (a*)₄₂₀ × 1000

Where,

  • (a*)₄₂₀ = attenuation index at 420 nm = A_b / (b × c)
  • A_b = attenuancy = −log T_s
  • T_s = transmittancy
  • b = cell length in cm
  • c = concentration of total solids as g/ml

Note: the printed forms (“a* = Ab C8 —log Ts”, “(ae)420 5 ie”) are garbled in the extraction; rendered here as the standard relationships the passage defines in words.

Procedure — ISI method

Weigh accurately 20 g of the sample, dissolve in water and make up to 50 ml in a volumetric flask

↓

Centrifuge the solution at 1000–1200 rpm for 15 min

↓

Measure the absorbance of the supernatant at 420 nm in a spectrophotometer using distilled water as blank

Calculation — ISI method

Extinction coefficient = (absorbance at 420 nm) / (concentration of sugar in g/ml × length of the absorption column in cm)

Where,

  • Absorbance at 420 nm = measured absorbance of the supernatant
  • Concentration of sugar = g/ml in the prepared solution
  • Length of the absorption column = cell length in cm

Note: the printed layout (“Extinction _ Absorbence at 420 nm / Concentration of sugar in g/ml × Length of the absorption column in cm”) is ambiguous in the extraction; rendered here as absorbance divided by the product of concentration and path length, the relationship the passage defines.

Precautions

  • Discard the first portion of the filtrate if it is cloudy.
  • Choose a cell length that gives a reading between 10 and 90% transmittancy.

References

Ranganna, S., Handbook of Analysis and Quality Control for Fruit and Vegetable Products, 2nd edition.

DeWhalley, H.C.S., ICUMSA Methods of Sugar Analysis, Elsevier Publishing Co., New York, 1964 — cited in the book.

Specification for Sugar used in Food Preservation Industry IS: 1679-1960, Indian Standards Institution, New Delhi — cited in the book.