SOP: Detecting Salmonella Rapidly by ADIAFOOD Real-Time PCR (MFLP-32)

GIFSQ ID: SOP-1034

Enrichment does slow work first, then molecular detection answers quickly. Once broths finish, this ADIAFOOD real-time PCR procedure picks out presumptive Salmonella positives within 3 hours, using primers and molecular beacons built for Salmonella spp. alone.

Beacon chemistry explains selectivity: probes fluoresce only after binding their target sequence, and fluorescence grows in proportion to amplified target DNA. Without target bacteria present, primers do not amplify DNA from other organisms under same reaction conditions, so no signal appears.

Purpose

Purpose is rapid presumptive detection of Salmonella species in validated foods and animal feed, for compliance under Sections 4 and 7 of the Food and Drugs Act and other relevant federal regulations. Every positive must be confirmed culturally.

Scope

Validated categories are: heat processed dairy products; ready-to-cook and processed cooked types within multi-ingredient composite foods; heat processed ready-to-eat meat and poultry; raw unprocessed meat; heat processed egg products; raw fish and crustaceans plus heat processed types within fish and seafood; and animal feed.

Other foods sit outside validated scope. A laboratory wanting to use system on an unlisted commodity must validate it properly for that commodity first, following Compendium validation criteria, before treating results as fit for purpose.

Equipment and Materials

  • Enrichment broths: brilliant green water, buffered peptone water (BPW), lactose broth, nutrient broth, tetrathionate brilliant green broth (TBG), Rappaport-Vassiliadis soya peptone broth (RVS)
  • ADIAFOOD kit, Kit # WAR5001: extraction buffer EX-1, lyophilised extraction reagent EX-2, detection buffer DT-1, lyophilised detection reagent DT-2, detection microplates or strip tubes with pre-dispensed PCR reagents, control strip tubes with detection strip kits, PCR optical-grade caps; kit primers and molecular beacon probes are molecular markers
  • ADIAFOOD extraction kit with extraction plates, domed caps and seals; strip holders; PCR capping tool
  • AES-validated real-time PCR thermocycler: 96-well (or 48-well) microplate, low and high profile, or 96 (48) × 0.2 mL tube capacity; excitation peak 485 to 520 nm; emission detection peak 500 to 600 nm
  • Conventional thermocycler for DNA extraction (optional); centrifuge with rotor and microplate carriers; vortex equipped for microplates; PCR enclosure (optional)
  • Two multi-channel pipettors and one single-channel pipettor; aerosol barrier tips; disposable multi-channel pipettor basins; sterile 2 mL microcentrifuge screw cap tubes; powder-free gloves
  • Stomacher and stomacher filter bags; incubators holding 35°C and 42°C; disposable serological pipettes; denatured alcohol and bleach
  • Sterile, DNase-free water, pipettes, tips and other materials touching samples or PCR reagents, autoclaved beforehand where applicable

Procedure

  1. Hold sample units refrigerated or frozen by product nature, except shelf-stable foods. Thaw frozen units in a refrigerator, or under time and temperature conditions preventing microbial growth or death, and analyse as soon as possible after receipt. Have sterile enrichment broth and supplies ready, and clean work surface with suitable disinfectant.
  2. Build a representative analytical unit: agitate liquids or free-flowing materials until homogeneous; for solids, take portions from several locations within unit.
  3. For most validated categories (heat processed dairy, ready-to-cook multi-ingredient composites, heat processed ready-to-eat meat and poultry, raw unprocessed meat, heat processed egg products, raw fish and crustaceans, heat processed fish and seafood, animal feed), enrich culturally as follows, in full: add 25 g or mL to 225 mL BPW or food-specific pre-enrichment broth (brilliant green water for fluid milk and frozen dairy; reconstituted non-fat dry milk for chocolate, cocoa, dry and low-moisture products), mix thoroughly, and incubate at 35°C for 18 to 24 h. Transfer 1.0 mL pre-enrichment into 9 mL TBG and 0.1 mL into 9 mL RVS, vortex, and incubate both selective broths at 42.5°C for 24 ± 2 h. Proceed to DNA extraction from selective enrichment, using two extraction wells per sample.
  4. For processed cooked multi-ingredient composite foods, use a direct route: add 25 g or mL to 225 mL lactose broth or nutrient broth in a blender jar or stomacher bag, blend, stomach or vortex for thorough mixing, and incubate pre-enrichment and controls at 35°C for 18 to 24 h. Proceed to DNA extraction using one extraction well per sample. Reserve an aliquot of pre-enrichment for selective enrichment under step 3, because presumptive positives need that material for cultural confirmation.
  5. Reconstitute extraction reagent: dispense EX-1 into EX-2 vial, recap, mix by inversion until desiccated reagent dissolves fully, then pour into a multi-channel pipettor basin.
  6. Aliquot 90 μL reconstituted EX-2 into each extraction microplate well: two wells per sample for step 3 route, one well per sample for step 4 route. Transfer 10 μL cell suspension from enrichment into wells according to sample assignment layout.
  7. Seal extraction wells with domed cap strips. Place plate in thermocycler and begin DNA extraction program; cycling lyses bacterial cells.
  8. Remove plate when program completes; organisms are lysed and inactivated. Centrifuge extraction microplate for 5 min at 1,800 × g. Supernatant is now usable for PCR amplification.
  9. Reconstitute detection reagent: DT-1 into DT-2 vial, recap, mix by inversion until fully dissolved, pour into a pipettor basin.
  10. Take detection microplate or strips from pouch, setting strips on a holder. Aliquot 15 μL reconstituted DT-2 into each detection well, then transfer 10 μL extracted DNA from extraction plate into corresponding detection wells.
  11. Seal detection plate or strips with optical-grade caps. Seal extraction microplate with provided seals and store at 4°C until analysis is complete.
  12. Invert detection plate or strips vigorously 4 times for thorough mixing. Tap gently to remove air bubbles from well bottoms, vortex for 1 min at maximum speed, and centrifuge for 1 min at 1,800 × g so PCR mixture, including DNA extract, sits at well bottoms.
  13. Secure detection plate or strips tightly in PCR instrument, well A1 at upper left corner, and start detection protocol. Remove and discard detection plate or strips once detection program completes.

Recording Results

Amplicons here are double-stranded DNA fragments from a Salmonella gene sequence. A positive shows fluorescence higher than baseline produced by negative controls within 40 cycles of amplification; system determines and sets baseline cut-off value. A negative normally produces no visible fluorescence. Record category route used, number of extraction wells per sample, cycle outcome, and control behaviour for each sample. Report positives as presumptive Salmonella spp. pending cultural confirmation.

Quality Control

Controls incubate and travel alongside samples on both enrichment routes. Fluorescence above baseline cut-off in negative controls invalidates results; repeat analysis with precautions eliminating possible error sources. Incubator control follows a strict pattern: 35°C may run at 35 ± 1.0°C, and lower temperatures such as 30 or 25°C likewise carry ± 1.0°C, while higher temperatures such as 43 or 45.5°C must hold within 0.5°C because heat can kill organisms being isolated. Media variations, commercial or made from scratch, are laboratory’s responsibility to prove equivalent. Work should meet ISO/IEC 17025 requirements.

Troubleshooting

  • Negative control fluoresces: invalidate run, decontaminate, refresh tips and reagents, and repeat; stray DNA is usual suspect.
  • No signal from a known positive control: check reagent reconstitution, well layout, and whether correct enrichment route and well count were used for that category.
  • Bubbles after sealing: repeat tap, vortex and centrifuge steps before starting detection rather than running a plate with liquid on walls.
  • New food type requested: stop and validate first; a clean run on an unvalidated matrix proves nothing about fitness for purpose.

Interferences and Limitations

Scope stops at validated categories listed above; assumptions about other foods carry no weight without validation data. Competing flora and food inhibitors are handled by enrichment, yet skipping selective enrichment on step 3 route removes part of that protection. A molecular positive detects target DNA in enriched broth and never replaces plating and confirmation.

Safety Notes

  • Treat all enrichments, especially selective broths, as potentially carrying Salmonella; use gloves, eye protection where splashing is possible, and biohazard disposal.
  • Keep denatured alcohol away from ignition sources and use bleach decontamination away from PCR setup areas.
  • Handle tetrathionate and brilliant green media with care, and discard used detection plates as contaminated material.

Source Method

Adapted in original wording from Health Canada method MFLP-32, Detection of Salmonella spp. using the ADIAFOOD Rapid Pathogen Detection System, A Real-Time PCR Technique, March 2016, Compendium of Analytical Methods, Volume 3. Cultural enrichment details stated in full above follow MFHPB-20, which this method incorporates for those categories.