Cooked meats left to cool slowly are a classic Clostridium perfringens story, and counts matter more than mere presence. A pour-plate method on sulfite cycloserine agar produces black presumptive colonies under anaerobic conditions, and a compact set of motility, nitrate and gelatin tests confirms what fraction of those colonies truly counts. Final numbers scale the presumptive count by the confirmed fraction.
Anaerobiosis makes or breaks the run. Indicators get checked before any colony is trusted, and plates stay upright because gas from growing colonies can displace agar in inverted plates.
Purpose
Purpose is to estimate viable C. perfringens per gram or millilitre of food, separating presumptive black colonies from confirmed organisms through defined biochemical behaviour.
Scope
Scope covers foods generally, with each sample unit analysed individually. Keep units refrigerated or frozen by product type except for shelf-stable foods, thaw frozen units in a refrigerator or under conditions preventing growth or death, and analyse promptly after receipt.
Equipment and Materials
- Sulfite cycloserine (SC) agar; nitrate-motility (NM) agar; lactose gelatin (LG); nitrate reagents; zinc dust
- Peptone water diluent 0.1%; 2% sodium citrate pre-warmed to 45°C, for cheese
- Stomacher, blender or equivalent; anaerobic jars, AnaeroGen atmosphere generation system or anaerobic incubator at 35°C; gas mix of 5% CO2, 10% H2 and 85% N2 for vented jars and incubators; anaerobic indicator per jar or incubator
- Aerobic incubator at 35°C; water bath at 45°C when citrate is used; colony counting device optional; rapid identification kits such as API 20A or VITEK 2 anaerobic cards optional
Procedure
- Prepare sterile 0.1% peptone water or the diluent a food requires, and disinfect working surfaces. Liquids such as milk and water may be pipetted directly and/or into peptone water with swirling or shaking; viscous and non-miscible liquids are weighed into peptone water and shaken; water-soluble solids and spices are weighed into peptone water and shaken; powders, meats and shellfish are weighed into peptone water and stomached or blended; cheese is weighed into 2% sodium citrate pre-warmed to 45°C and stomached or blended. Diluent may be added to sample already placed in a sterile bag, jar or bottle before mixing.
- Homogenise liquids and free-flowing materials to uniformity, and build solid units from portions taken at several locations.
- Make a 1 in 10 dilution by shaking, stomaching or blending 25 g or mL into 225 mL diluent. Other sizes keep the ratio, for example 11 g in 99 mL or 10 g in 90 mL.
- Blend only as long as homogeneity requires and never beyond 2.5 min, since overheating injures cells. Foaming foods need low speed with sampling from below the foam interface. Bottle dilutions get shaken 25 times through a 30 cm arc in about 7 seconds, and stomacher samples get macerated for 1 min.
- Rest dry-food homogenates at room temperature for 15 min; continue every other food without delay. Prepare further decimal dilutions with a fresh sterile pipette per transfer, shaking each dilution immediately before transferring.
- Pipette 1 mL of each required dilution into duplicate sterile plates. Pour about 20 mL sulfite cycloserine agar into each plate and mix by gentle rotation.
- Incubate plates anaerobically and upright at 35°C for 20 h; longer incubation blackens plate rims excessively. Small batches suit anaerobic jars or an AnaeroGen system by manufacturer directions, while large batches suit an anaerobic incubator. Jars and incubators using gas replacement need three evacuations and refills with 5% CO2, 10% H2 and 85% N2, plus an anaerobic indicator in every jar and incubator.
- Check indicators after 20 h and confirm anaerobiosis before counting. Failed anaerobiosis ends the analysis; no count proceeds without it.
- Confirm at least five presumptive colonies, chosen at random from plates in the acceptable range, or every presumptive colony when fewer than five exist. Stab each colony into NM agar and, in parallel, deep into LG. Close tubes and incubate anaerobically at 35–37°C for 24 h alongside uninoculated NM and LG controls.
- Read NM tubes showing a distinct non-motile growth line along the stab by adding 0.2–0.4 mL nitrate reagent: red colour at the top means nitrate was reduced to nitrite, a positive result, while faint colour barely stronger than blanks counts as negative. Add a pinch of zinc dust to negative tubes: red after zinc means nitrate remained, so the test stays negative; no colour change after zinc means nitrate was reduced beyond nitrite, so the test is positive. Growth confined to a tube bottom with little colour calls for aspirating and discarding the upper medium, then adding reagent again to the remainder.
- Read LG tubes for gas production and a red-to-yellow shift showing lactose fermentation. Chill LG tubes in ice water for 10 min or refrigerate for 1 h, then examine for liquefaction. A non-motile, nitrate-reducing, lactose-positive isolate without liquefaction at 24 h earns another 24 h at 35–37°C; liquefaction within 48 h completes confirmation.
- Accept rapid identification kits as an additional confirmation route by manufacturer directions, without dropping the core pattern for isolates tested culturally: confirmed C. perfringens is non-motile, reduces nitrate to nitrite, ferments lactose and liquefies gelatin within 48 h.
Recording Results
Choose plates holding 20–200 black colonies of about 1–2.5 mm diameter; pinpoint black colonies never count. Average duplicate presumptive counts and compute a presumptive count N = A × D, where A is the average presumptive count from duplicate plates and D is the dilution factor. Plates outside 20–200 may be used when nothing falls inside the range.
Letter flags carry meaning: when the lowest colony count per plate still exceeds 200, count or estimate and append E for lower accuracy, for example 1.8 × 106 E; when numbers defy estimation, report a minimum with a > sign, for example >2.0 × 106. Counts from plates all below 20 also take E, for example 1.2 × 103 E. No presumptive colonies at all reports as <0.5 × D.
Derive the confirmed count as: confirmed count per g (mL) = presumptive count per g (mL) × (colonies confirmed ÷ colonies tested). No confirmed colonies reports as <0.5 × D, where D is the dilution factor. Record indicator status, plate counts by dilution, colonies picked, and each NM and LG outcome so the confirmed fraction can be audited.
Quality Control
Anaerobic indicators govern run validity, and uninoculated NM and LG tubes control the confirmation media in every batch. A stated 35°C allows 35 ± 1.0°C, lower temperatures of 30°C or 25°C allow ± 1.0°C, but any higher selective temperature must hold within 0.5°C. Media substitutions require laboratory equivalency proof.
Troubleshooting
- Indicator shows oxygen: stop, review jar seals, gas replacement cycles and AnaeroGen handling, then repeat from fresh dilutions.
- Excess blackening hiding colonies: shorten any drift beyond 20 h and favour a higher dilution on repeat.
- Agar displaced in plates: confirm plates incubated upright; gas production lifts agar in inverted plates.
- Ambiguous nitrate colour: run the zinc step and the aspirate-and-retest step for bottom-only growth before scoring.
- Gelatin still solid at 24 h: re-incubate a full second day before rejecting an otherwise matching isolate.
Interferences and Limitations
Other sulfite-reducing clostridia can produce black colonies, so presumptive counts overstate C. perfringens until confirmation corrects them. Motile or nitrate-negative look-alikes fail confirmation by design. Counts outside the 20–200 window carry estimate status, and any failure of anaerobiosis invalidates growth rather than merely weakening it.
Safety Notes
- Handle C. perfringens cultures and anaerobic jars under standard pathogen precautions, venting gas systems only by manufacturer and local safety procedures; hydrogen-containing gas mixes demand strict separation from ignition sources.
- Manage hot citrate, molten agar and zinc dust with gloves and eye protection, and add nitrate reagents carefully over contained trays.
- Dispose of anaerobic plates and confirmation tubes as biohazard waste without opening overgrown plates on an open bench.
Source Method
Adapted in original wording from Health Canada method MFHPB-23, Enumeration of Clostridium perfringens in Foods, June 2015, Compendium of Analytical Methods, Volume 2.