SOP: Counting Aerobic and Anaerobic Spore-Forming Bacteria in Foods (MFLP-44)

GIFSQ ID: SOP-1045

Heat does most of the selection work in this count. A diluted food suspension is held at 75°C long enough to kill vegetative cells, leaving only spores to grow, and parallel pour plates then answer two different questions: how many spore-formers grow with oxygen present, and how many grow without it. Each result is reported separately, as an aerobic spore-former count and an anaerobic spore-former count per gram or millilitre.

Duplicate plates, a narrow preferred colony range and a fixed rounding rule keep small technique differences from becoming large differences in the reported number.

Purpose

Purpose is to enumerate viable spore-forming micro-organisms in foods, as separate aerobic and anaerobic counts, for compliance with Sections 4 and 7 of the Food and Drugs Act. Working assumption is that every viable spore surviving heating multiplies under the stated conditions and forms one visible colony.

Scope

Scope covers foods generally. Each sample unit is analysed on its own, never composited. Except for shelf-stable foods, hold units refrigerated or frozen according to product type until analysis, thaw frozen units in a refrigerator or under conditions that prevent growth or death, and start work as soon as possible after receipt. Work follows ISO/IEC 17025:2005 (or latest version). Any commercial or in-house variation on listed media must have equivalency shown by the analyst or laboratory supervisor.

Equipment and Materials

  • Tryptic soy agar (trypticase soy agar); 0.1% peptone water diluent
  • Water baths adjustable to 45°C and 75°C; incubator adjustable to 35°C; refrigerator
  • Blender; pH meter; thermometer reading to 75°C; colony counter; tally register
  • Petri plates; anaerobic jar with a system producing an anaerobic atmosphere, such as the BBL GasPak system
  • 1 N NaOH and 1 N HCl for pH adjustment; suitable disinfectant for the work surface
  • 0.1% 2,3,5-triphenyltetrazolium chloride solution for distinguishing colonies from food particles
  • 2% sodium citrate (Na3C6H5O7.2H2O) for processed cheese, warmed to 45°C before use

Procedure

  1. Prepare trypticase soy agar, dispense in suitable amounts and sterilize. Melt and temper in a 45°C water bath with bath water standing about 1 cm above medium level in the bottles. Disinfect the work surface. Label duplicate plates clearly with sample, sample unit, dilution and inoculation date.
  2. Make the suspension represent the whole unit. Agitate liquids and free-flowing materials until homogeneous; for solids, draw the analytical portion from several locations within the unit. Aseptically combine 10 g or mL with 90 mL sterile 0.1% peptone water for a 1:10 dilution. Disperse by food type: milk, water and other liquids are pipetted directly and/or weighed into diluent and shaken; viscous liquids are weighed into diluent and shaken; water-soluble solids are weighed into diluent and shaken; powders and meats are weighed into diluent and blended; processed cheese is weighed into pre-warmed (45°C) 2% sodium citrate and blended; spices are weighed into diluent and shaken.
  3. Keep homogenisation controlled. Blending must not exceed 2.5 min, to avoid overheating. Run foaming foods at low blender speed and draw aliquots from below the liquid–foam interface. Shaking means 25 shakes through a 30 cm arc in about 7 seconds. A percent-basis start is also allowed where a more accurate weight is wanted: a 10% suspension holds 10 g (mL) per 100 g (mL) of suspension, whereas a 1:10 dilution holds 10 g (mL) of product plus 90 g (mL) of diluent.
  4. Check suspension pH. Outside 5.5–7.6, bring pH to 7.0 with sterile 1 N NaOH or 1 N HCl.
  5. Heat-treat for spore selection. For each analytical unit, pipette 20–25 mL of the 10−1 dilution into a sterile tube. Fill one extra tube with 20–25 mL of the same dilution and place a thermometer in it as the control tube. Set tubes in a 75°C water bath, shake intermittently until the control-tube thermometer reads 75°C, then hold a full 20 minutes at that point.
  6. Prepare further dilutions only from the heat-treated 10−1 dilution, in 0.1% peptone water, with a fresh sterile pipette for each transfer. Suggested series is 10−1, 10−2 and 10−3. Shake every dilution immediately before each transfer so organisms stay evenly distributed. Pour plates within 15 minutes of preparing dilutions.
  7. Plate in duplicate. Agitate each dilution to resuspend settled material, then pipette 1 mL or 0.1 mL of each required dilution into appropriately marked duplicate Petri plates. For products that stick to the plate base, deliver inoculum into 1.0 mL of sterile diluent already placed in the plate. For aerobic spore-formers, pour 12–15 mL of tempered agar per plate and mix by rotating and tilting. For anaerobic spore-formers, pour no more than 10 mL of melted agar per plate. Let plates solidify.
  8. Incubate by atmosphere. Aerobic plates go inverted at 35 ± 0.5°C for 48 ± 2 h, without crowding or excessive stacking, so plates equilibrate quickly with incubator temperature. Anaerobic plates go into an anaerobic atmosphere, for example one generated by the BBL GasPak system.
  9. Count promptly when incubation ends. Prefer plates holding 20–200 colonies, pinpoint colonies included; when no plate falls in range, use plates nearest to that range. Count with a colony counter and tally register. Where spreaders cover part of a plate, count a representative spreader-free portion and scale up by the reciprocal of the fraction counted: for example, 30 colonies on one quarter of a plate gives a whole-plate estimate of 30 × 4 = 120 colonies.
  10. Separate true colonies from food debris when particles interfere, using either comparison or staining. Comparison option: pour one extra plate at each affected dilution and hold it refrigerated, then compare during counting. Staining option: flood the incubated plate with 2 mL of 0.1% 2,3,5-triphenyltetrazolium chloride, rock gently side to side to cover the whole surface, pour off excess, and leave inverted at room temperature for 3 hours; living colonies reduce the indicator to a red formazan and stand out from particles. Colonies treated this way cannot be picked for isolation afterwards.

Recording Results

Average duplicate plates as an arithmetic mean, following the worked examples in Table 5-1 of Standard Methods for the Examination of Dairy Products, APHA, 14th edition. Compute the count as N = A × D, where N is colonies per g (mL) of product, A is average count per plate and D is the dilution factor for that dilution. Round reported counts to two significant figures, keeping only the first two left-hand digits: for example, 2,850 is reported as 2,900. Flag counts outside the preferred range as estimated (E) in line with the source examples: an average of 244 at 1:1000 reports as 240,000; a count above range, such as 440 at the highest dilution, reports as 440,000 E; a count below range, such as 25 at the lowest dilution, reports as 25,000 E. When the lowest dilution plated shows no colonies, report a less-than value built from the lowest average obtainable with the volume plated on that replicate set: with duplicate 1 mL plates, one colony on one plate only gives (1 + 0) / 2 = 0.5, so an undiluted result reports as < 0.5, and for other dilutions multiply 0.5 by the dilution factor (for 10−1, the factor is 1 / 10−1 = 10); no growth at 1:1000 therefore reports as < 500 per g or mL. Record aerobic and anaerobic counts separately, with dilutions, volumes plated and any spreader or particle corrections noted.

Quality Control

Incubators and water baths must hold recommended temperatures: a stated 35°C allows 35 ± 1.0°C, as do 30°C or 25°C settings, but higher settings such as 43°C or 45.5°C must hold within 0.5°C because excess heat can kill the organisms sought. As generic laboratory practice, verify the 75°C step from the control-tube thermometer rather than bath setting alone, confirm each jar actually became anaerobic, and check tempered agar temperature before pouring.

Troubleshooting

  • Counts unexpectedly low after heating: confirm the 20-minute hold began only once the control tube itself reached 75°C, and that blending stayed within 2.5 min without overheating the suspension.
  • Food particles mistaken for colonies: use the refrigerated comparison plate, or apply the triphenyltetrazolium chloride flood and count only colonies turned red.
  • Spreaders obscuring colonies: count a clean representative area and scale by the reciprocal of the fraction counted; record that the value is an estimate from a partial plate.
  • No plate inside 20–200 colonies: count the plates nearest the range and flag the reported result as estimated (E).
  • Anaerobic plates showing poor growth: check jar sealing and gas generation, and confirm no more than 10 mL of agar was poured for anaerobic plates.

Interferences and Limitations

Meat, milk powder and similar particles can mimic colonies and inflate counts unless the comparison-plate or indicator options are used. Foaming during blending, settling before transfer, and delays beyond 15 minutes between dilution and pouring all bias recovery. Heating selects for spores by design, so vegetative cells are not counted, and the anaerobic result depends entirely on a genuinely anaerobic jar atmosphere being achieved.

Safety Notes

  • Treat all food suspensions and incubated plates as potentially carrying pathogenic spore-formers; use standard microbiological precautions and biohazard disposal.
  • Handle the 75°C water bath, hot agar and 1 N acid and alkali with gloves and eye protection, and take care with blender blades and broken glass.
  • Disinfect work surfaces with a suitable disinfectant before plating, as the procedure requires, and decontaminate spills promptly.

Source Method

Adapted in original wording from Health Canada method MFLP-44, Determination of aerobic and anaerobic sporeformers, March 2012, Compendium of Analytical Methods, Volume 3. This revised method replaced MFLP-44 dated April 1998.