SOP: Collection and Transportation of Food Samples for Microbiological Analysis (Appendix B)
GIFSQ ID: SOP-0962
Good microbiology starts long before a plate is poured. A result can only reflect a lot if sampling captures that lot fairly and transport holds its microflora steady until analysis begins. Handled loosely, even a sound method will report on growth or die-off that happened in transit, not on food as it left production or reached a shopper.
Procedure below sets out how many units to draw, how large each unit must be, which containers to favour, and what temperatures to hold in transit. Follow it for foods, food ingredients and environmental samples examined with bacterial methods, unless a commodity plan or an individual method directs otherwise.
Purpose
Aim is to obtain a representative sample from each lot and deliver it to a laboratory in a condition that preserves, as closely as practical, viable microflora present at collection. Consistent unit numbers, unit sizes and transport conditions also make results comparable between lots, sites and sampling occasions.
Scope
Coverage extends to collection and transport for all bacterial examinations of foods, ingredients and environmental samples. Sampling plans for a specific commodity, or instructions inside an individual method, take precedence where they set a different unit number, unit size or holding condition. Routine examination of shelf-stable, refrigerated, frozen and fresh produce all fall within scope.
Equipment and Materials
- Sterile sample containers, sized to hold at least 100 g or 100 mL per sample unit
- Sterile sampling tools suitable for bulk product, used aseptically
- Original unopened retail or production containers, where available
- Refrigerated transport containers or insulated boxes with refrigerant, capable of holding refrigeration temperature in transit
- Freezer transport containers capable of keeping frozen product frozen throughout shipment
- Labels and sampling records identifying lot, location, date and number of units drawn
- Gloves and hand hygiene supplies for aseptic collection
Procedure
- Define a lot before sampling. Treat product sharing a common code as one lot. Where no code exists, regard as one lot either product made under essentially identical conditions at one establishment within no more than one day of production, or a quantity of one kind of product from one manufacturer available together at one fixed location.
- Draw units at random from each lot. Build a sample from between 5 and 60 sample units, using a number fixed by a sampling plan or method where one applies.
- Size each unit at a minimum of 100 g or 100 mL. Accept a smaller unit only where a method stipulates it or a commodity sampling plan requests it.
- Prefer an original unopened container for each unit whenever one can be obtained.
- Handle bulk product with care to keep sampling representative. Draw several units from one bulk container if needed, but never draw every required unit from a single container. Where a lot holds fewer containers than units required, more than one unit may come from a large institutional or bulk container.
- Place any unit collected from bulk into a sterile container immediately after collection.
- Combine small containers into one unit where lot containers fall below minimum size. For example, four containers of 25 g or 25 mL together make one 100 g or 100 mL sample unit. A unit may therefore consist of more than one container.
- Use aseptic technique throughout collection. Keep sterile containers closed until filling, avoid contact between product and non-sterile surfaces or hands, and close each container promptly after filling.
- Label each unit at collection and record lot identity, sampling location, date, product condition and number of units taken.
- Hold and transport each unit under conditions matching product nature. Keep perishable product refrigerated and frozen product frozen during transport. Move shelf-stable product at room temperature.
- Send fresh fruit and vegetables under refrigeration even when they were displayed and sold at ambient temperature. Chilling limits overgrowth of mesophilic background flora that could otherwise mask a target pathogen, and keeps flora closer to its state when a consumer bought the produce.
- Prevent thawing of product that is normally frozen while it is in shipment. Pack and monitor frozen units so they arrive still frozen.
- Inspect condition and temperature on arrival. Log any thawing, damage, leakage or temperature abuse before a decision on analysis is made.
- Deal with thawed frozen product by a fixed rule. Never refreeze a unit that has thawed in transit. Where a thawed unit arrives at a suitable temperature, for example between 0 and 7°C, proceed to analysis immediately rather than holding it for later work.
Recording Results
Record for each lot: number of sample units drawn, size of each unit, container type (original unopened, bulk transfer or combined small containers), collection technique notes, transport condition applied, and arrival condition and temperature. Flag any unit that thawed, arrived outside a suitable temperature, or fell below 100 g or 100 mL without a method or plan authorising a smaller size. Analytical reports should link results to a defined lot and to an identified sample, meaning total units taken for that lot, so a reader can judge representativeness. No calculation applies at this stage; numerical results come from examination of analytical units withdrawn from sample units in a laboratory.
Quality Control
Verify randomness in practice: units should come from across a lot, not from one convenient pallet, case or container. Check sterile containers for integrity before use and discard any with compromised seals. Confirm transport containers hold refrigeration or frozen conditions for expected journey length before dispatch, as generic good transport practice. On receipt, compare unit count and identity against sampling records and quarantine any unit whose identity or holding history cannot be established.
Troubleshooting
- Lot has fewer containers than units required: take more than one unit from large institutional or bulk containers so required unit number is still met, and note arrangement on sampling record.
- Individual containers are too small: group enough containers together to reach at least 100 g or 100 mL per unit, keeping grouped containers together as one unit through transport and receipt.
- Frozen product arrives thawed: do not refreeze. Assess arrival temperature; if it lies in a suitable range such as 0 to 7°C, analyse without delay and document thawing prominently.
- Fresh produce was held at ambient temperature at point of sale: still transport it refrigerated. Ambient display does not justify ambient shipment.
- Original containers are unavailable: collect aseptically into sterile containers, taking extra care to avoid contamination and to spread collection across a lot.
Interferences and Limitations
Transport abuse distorts counts in either direction: warmth encourages multiplication, while freezing, thawing and prolonged holding can injure or kill vegetative cells. A sample drawn non-randomly or drawn entirely from one container cannot support conclusions about a whole lot, however careful later analysis may be. Minimum unit size also matters for detection: very small units reduce chance of capturing unevenly distributed contamination. Environmental samples and ingredients follow same principles, with unit definition adapted to material sampled while preserving random selection, asepsis and temperature control.
Safety Notes
- Apply standard food-handling hygiene during collection: clean hands, intact gloves, and no sampling while ill with symptoms that could contaminate food, as generic laboratory and field practice.
- Handle broken, swollen or leaking containers as potentially hazardous; isolate them and avoid direct contact with contents.
- Manage dry ice or other frozen refrigerants, where used, with gloves and ventilation, as generic transport practice; never seal refrigerant in an airtight container.
- Treat all collected foods as potentially containing pathogens until examination proves otherwise.
Source Method
Based on Health Canada Appendix B, Collection and Transportation of Samples, Volume 1 of Compendium of Analytical Methods, issued November 2006, applicable to all methods in that compendium. Wording, structure and presentation here are original to this SOP; sampling numbers, unit sizes and transport conditions reproduce source requirements.