SOP: Antimicrobial Packaging Films: Efficacy (Challenge) Test against Foodborne Microorganisms
GIFSQ ID: SOP-0970
Growth on a food’s surface drives much spoilage, and surfaces pick up contamination during handling, processing and packaging. Antimicrobial packaging tries to meet that problem at the surface itself: an agent carried in or on the film is released slowly where microorganisms land. Testing such a film means more than showing the agent is present. A known load of a target organism has to be placed on the film, given time in contact with the agent, and then recovered and counted, alongside an untreated control film carrying no agent at all.
Worked here is the laboratory study from Chapter 3, in which nisin, a bacteriocin produced by Lactococcus lactis, was coated onto low density polyethylene (LDPE) film in a cellulose-based coating and challenged with Staphylococcus aureus and Listeria monocytogenes. Both organisms are Gram positive, which matters: nisin is selective for Gram positive bacteria and is not effective against Gram negative bacteria.
Purpose
Purpose is to determine whether an antimicrobial film, and at what agent concentration, inhibits growth of selected foodborne microorganisms on the film surface under a defined contact period, using nisin-coated LDPE challenged with S. aureus and L. monocytogenes as the worked method.
Scope
Scope covers a non-food challenge system: coated film squares are inoculated, held, then pressed onto agar for recovery and enumeration. Findings show what a coating can do on the film surface itself. Performance on a real food will also depend on water activity, pH, temperature, and interaction between agent and film matrix, all discussed in the source chapter and summarised under Interferences and Limitations. Other delivery forms reviewed in the chapter, such as agents mixed into the polymer matrix, antimicrobial powders dusted inside bags, vapour-releasing systems and sachets, sit outside this procedure.
Equipment and Materials
- Low density polyethylene film, 1.5 mil
- Methylcellulose and hydroxypropyl methylcellulose for the coating carrier
- Distilled water, 95% ethanol, and polyethylene glycol as plasticiser
- Nisin, and 0.02 N hydrochloric acid for preparing nisin solutions
- Thin layer chromatography plate coater set to 500 µm, and glass plates, 8 × 8 in
- UV light source for surface sterilisation of film samples
- Cultures of Staphylococcus aureus and Listeria monocytogenes, prepared at the inoculum levels given in the procedure
- Tryptic Soy Agar plates for recovery, modified Oxford agar for confirming L. monocytogenes, and Gram stain reagents for confirming S. aureus
- Incubator at 35°C
Procedure
- Prepare the coating base. Slowly add 7.0 g methylcellulose and 3.0 g hydroxypropyl methylcellulose to 100 mL distilled water and stir until completely dissolved. Slowly add 200 mL of 95% ethanol, then add 6 mL polyethylene glycol as plasticiser.
- Prepare the nisin solutions in 0.02 N hydrochloric acid. Dissolving 2.0 g nisin in 10.0 mL gives the 200 IU/mL concentration as stated in the chapter; prepare the rest of the series the same way, using 1.5 g for 150 IU/mL, 1.0 g for 100 IU/mL and 0.5 g for 50 IU/mL, each in 10 mL.
- Make up a coating solution at each level: 200, 150, 100, 50 and 0 IU/mL nisin. That zero level is the control coating, carried through every later step in exactly the same way as the treated films.
- Coat the film. Cover glass plates (8 × 8 in) with LDPE film and pass each plate through the thin layer chromatography plate coater set at a thickness of 500 µm, so the coating solution is applied in a uniform layer.
- Dry every coated material overnight at room temperature.
- Cut film samples into 2 inch squares, giving the 25 cm² test area used for reporting. Sterilise each square under UV light for 2 minutes before inoculation, because handling during coating and cutting can contaminate the surface. Exposure time was settled by a preliminary check at 1, 2 and 3 minutes, in which 2 minutes proved sufficient.
- Inoculate the samples separately, soaking film squares with a solution containing 10⁶ CFU/mL S. aureus, and other squares with a solution containing 10⁵ CFU/mL L. monocytogenes. Keep the two organisms on separate samples throughout.
- Store all inoculated samples at room temperature for 24 hours, allowing nisin time to act on the bacteria on the film surface.
- Recover survivors. Transfer each film square, coated side down, onto a Tryptic Soy Agar plate, and incubate at 35°C for 48 hours.
- Count colonies and select colonies for identification. Confirm S. aureus by Gram stain, and confirm L. monocytogenes by growth on modified Oxford agar with formation of black colonies.
- Perform every treatment level, for each organism, in triplicate.
Recording Results
Report results as CFU per 25 cm², based on the area of the film sample, for each nisin level and each organism, giving the triplicate values rather than a pooled figure alone. Chapter 3 reports its outcome in that form: starting from 160 CFU/25 cm² of S. aureus and 21 CFU/25 cm² of L. monocytogenes on the zero-nisin control film, counts fell to 0 for S. aureus at 100 IU/mL and above, while L. monocytogenes results varied between replicates at 50 to 150 IU/mL, with no trend determinable, and reached 0 only at 200 IU/mL. Read a level as effective for an organism only where the triplicate results support that reading consistently; where replicates disagree, say so plainly in the report, exactly as the chapter does for the middle L. monocytogenes levels. No log-reduction value is calculated in the source method, and none should be added in reporting.
Quality Control
- Carry the 0 IU/mL coated film through coating, drying, UV sterilisation, inoculation, storage and recovery in parallel with every treated level: without that control count, a low survivor count cannot be credited to nisin.
- Confirm the identity of recovered colonies by the Gram stain and modified Oxford agar checks in the procedure, so counts are not inflated by stray contaminants picked up during film handling.
- Verify UV exposure before the main run, using the 1, 2 and 3 minute preliminary check described in the chapter, whenever film, lamp or handling practice changes.
- Expect low transfer of inoculum onto dry film: the chapter attributes the low levels recovered to low moisture content on the film surface, so record the actual control count for every run instead of assuming the soak concentration reached the film.
Troubleshooting
- Very few colonies even on control film: check film surface moisture and inoculation technique first. Dry film takes up little inoculum, and a weak control invalidates comparison across nisin levels.
- Replicates at one level disagree widely: repeat that level in triplicate and report the spread. Variable results at intermediate nisin levels were a genuine finding in the source study, not noise to be hidden.
- Coated film will not heat seal, or looks hazy: note it in the report. A noticeable decrease in clarity and difficult heat sealing with impulse and hot bar sealers were observed for the methylcellulose coating, and both matter for commercial use.
- Growth appears on uninoculated film: revisit handling and UV sterilisation; contamination during formation and cutting is the recognised route in the chapter.
Interferences and Limitations
Water activity changes everything in this kind of system: higher water activity raised permeation of a preservative through polysaccharide films in the studies reviewed, draining the surface protection faster. pH pulls the other way for some agents, with sorbic acid permeation falling as pH rose from 3.0 to 7.0, and benzoic anhydride film working better against moulds at lower pH. Warmth speeds diffusion out of the carrier, so a film balanced for refrigeration may exhaust itself at room temperature, while cold storage can let lower agent levels do the work. Agent and matrix must also suit each other chemically: polarity, molecular weight and ionic state all change permeation, and nisin’s Gram positive selectivity means a film proven here says nothing about Gram negative pathogens. Finally, an antimicrobial system is an added protective measure alongside good quality control, never a cover for poor practice, and regulatory approval of the agent for the intended food must be checked separately.
Safety Notes
- Handle S. aureus and L. monocytogenes cultures as pathogenic microorganisms, using the laboratory’s standard containment, aseptic technique and culture disposal practice.
- Treat UV sterilisation as an eye and skin hazard: shield the lamp and never view it directly during the 2 minute exposure.
- Hydrochloric acid solutions and 95% ethanol call for gloves, eye protection and, for ethanol, keeping clear of ignition sources.
- Decontaminate inoculated film, plates and soak solutions before disposal, since survivors can remain viable after the 24 hour contact period.
Source and Standard
Adapted from Risch (ed.), Food Packaging: Testing Methods and Applications (ACS Symposium Series 753, American Chemical Society, 2000), Chapter 3, “Utilization of Antimicrobial Packaging Films for Inhibition of Selected Microorganisms” by K. Cooksey of Clemson University, including its review of factors that govern antimicrobial packaging performance.