Food Analysis Methods and Laboratory Procedures
Explore scientific laboratory methods and practical analytical procedures used in food science and technology. This section provides technical resources covering physical, chemical, microbiological, nutritional and sensory analysis of food products.
SOP: Test for Peroxidase Activity in Vegetables
Food AnalysisPrinciple Peroxidase is among the most heat-resistant enzymes in vegetables. Its residual activity, shown by the guaiacol–hydrogen peroxide colour reaction, has been found to correlate with the keeping quality of frozen vegetables in frozen storage; the test is applicable to frozen peas, snap beans, asparagus and cut corn, and may hold good for other […]
SOP: Qualitative Detection of Catalase in Vegetables
Food AnalysisPrinciple Raw or under-blanched vegetables discolour, lose flavour and develop off-odours in frozen storage because of enzyme action. Catalase, one of the most heat-resistant enzymes in vegetables, decomposes hydrogen peroxide into oxygen and water; the volume of oxygen liberated in Thompson’s manometric apparatus gives a qualitative detection and rough estimation of residual catalase activity. […]
SOP: Estimation of Approximate Fruit Content of Fruit-Sugar Mixtures
Food AnalysisPrinciple In a mixture of fruit and dry sugar, the fruit content is calculated from the soluble solids of the mixture and the known soluble solids content of the fruit used: the added dry sugar is taken as 100% solids, and the fruit fraction is obtained by difference. Apparatus required High speed blender Refractometer […]
SOP: Determination of Total Soluble Solids in Frozen Fruits
Food AnalysisPrinciple The total soluble solids (TSS) content of quick frozen fruits is determined refractometrically: the thawed sample is blended and filtered, the refractometer reading of the clear serum is corrected to 20°C, and the result is expressed in terms of the International Sucrose Scale. Apparatus required High speed blender Filter paper or other filtering […]
SOP: Determination of Drained Weight of Frozen Fruits and Vegetables
Food AnalysisPrinciple The frozen package is thawed in a water bath under standardised conditions, the contents are drained on a standard sieve for a fixed time, and the drained weight is expressed as a percentage of the net weight of the package. Apparatus required Water bath maintained at 30 ± 1°C, kept agitated Number 8 […]
SOP: Thawing of Quick Frozen Fruits and Vegetables
Food AnalysisPrinciple Quick frozen fruits and vegetables are thawed by a standardised procedure: in air or in water: chosen so that the product thaws rapidly without altering or degrading its characteristics, and without leaching soluble solids from cut surfaces. Procedure Use the entire package; for bulk products use 1–2 kg of a representative sample ↓ […]
SOP: Determination of Fill of Container for Frozen Fruits
Food AnalysisPrinciple The fill of the container is determined by comparing the volume of the frozen fruit, measured by displacement in cold mineral oil, with the water capacity of the outer container. Apparatus required Overflow can: a watertight stainless steel tank, 23 cm (H) × 20 cm (D), with an overflow spout of copper tubing […]
SOP: Determination of Net Weight of Frozen Foods
Food AnalysisPrinciple The net weight of the contents of a frozen package is obtained gravimetrically: the frozen package is weighed with its frost and ice, then the contents (including product particles and frost crystals) are removed, the empty package is air-dried, and the difference gives the net weight. Apparatus required Scale of adequate capacity with […]
SOP: Measurement of Product Temperature in Frozen Foods
Food AnalysisPrinciple Frozen blocks often carry large temperature gradients: during or just after freezing, or after exposure to ambient air: and the maximum product temperature in storage and handling must be measured directly inside the product. A thin probe, pushed in roughly along the food’s major axes, gives the best reading in a frozen block. […]
SOP: Determination of Mineral Impurities in Canned Products
Food AnalysisPrinciple Sand and other inorganic materials are separated from the plant tissue by floatation and sedimentation: being heavier, the sand and earthy particles sink to the bottom of the receptacle, where they are collected, incinerated, weighed and reported as “mineral impurities”: technically the water-insoluble inorganic residue, which includes not only silica but also other […]
SOP: Determination of Calcium in Canned Vegetables
Food AnalysisPrinciple Calcium in canned vegetables (applicable to canned lima beans, potatoes and tomatoes) is determined by complexometric titration: the product is ashed, the ash solution is passed through an ion exchange column of high phosphate capacity, and the calcium is titrated with standard EDTA solution using hydroxynaphthol blue indicator. Apparatus required Titration stand, fluorescent […]
SOP: Determination of Alcohol-Insoluble Solids in Canned Peas and Corn
Food AnalysisPrinciple The maturity of canned peas is related to the alcohol-insoluble solids (AIS): starch, hemicellulose, fibre and proteins: tender green peas have lower AIS values than mature ones. The sample is boiled with 80% alcohol, the alcohol-insoluble residue is collected on a weighed filter paper, dried at 100 °C and weighed. Apparatus required White […]
SOP: Determination of Soluble Solids by Calculation
Food AnalysisPrinciple The soluble solids are found by difference: the insoluble solids determined gravimetrically are subtracted from the total solids. Purpose To determine soluble solids by calculation from the total solids and the insoluble solids of the same sample. Scope Applies to fruit and vegetable products where total solids and insoluble solids are determined on […]
SOP: Determination of Insoluble Solids in Canned Products
Food AnalysisPrinciple The soluble matter is washed out of the blended solids with repeated hot-water washings; the insoluble residue is collected on a weighed filter paper, dried at 100 °C and weighed. Apparatus required Buchner funnel Dried and weighed filter paper Hot air oven Desiccator Centrifuge Weighing balance Reagents a. Hot water. Procedure Rinse 20 […]
SOP: Determination of Total Solids in Canned Products
Food AnalysisPrinciple Total solids are determined gravimetrically by drying the prepared sample on diatomaceous earth in a vacuum oven at 70 °C; the method is an alternate to minimum drained weight in canned mature processed peas, and the result is converted to total solids as a percentage of the water capacity of the container. Apparatus […]
SOP: Tough String Test for Beans
Food AnalysisPrinciple Strings are removed from individual bean pods and hung so that each string supports a 250 g clamp assembly; a string that supports the weight for five seconds or longer is considered a tough string, and the pods containing them are weighed and expressed as a percentage of the test sample. Apparatus required […]
SOP: Calculation of Initial Strength of Covering Syrup for Desired Cut-out Strength
Food AnalysisPrinciple The concentration of the covering syrup used in canning is greater than the final cut-out strength: during processing the syrup strength falls, and during storage the total sugar distributes itself evenly between the fruit and the liquor. The initial syrup strength needed to reach a desired final strength is calculated from the weights […]
SOP: Detection of Foreign Bodies in Canned Products
Food AnalysisPrinciple Foreign bodies are separated according to their nature: glass fragments are recovered by liquefying solid or pasty foods with dilute nitric acid, light materials are separated on a fine sieve with a water stream, and heavy inorganic matter is separated by washing and sedimentation. Apparatus required Flask Fine sieve Large container (for the […]
SOP: Incubation Test for Spoilage of Canned Products
Food AnalysisPrinciple Cans are incubated at 37 °C and 55 °C for 7 days to reveal living microorganisms: gas-forming mesophiles swell the cans at 37 °C, while flat-sour organisms (which do not grow at low temperatures) are detected at 55 °C; stained slide examination of the contents distinguishes leaker spoilage from under-processing. Apparatus required Incubators […]
SOP: Determination of Salt Content in Canned Vegetable Brines
Food AnalysisThe brine in a can of vegetables carries the salt the product was packed in, and the salt level matters for taste, for the label and for the process. This SOP measures the chloride in the brine by titration with standard silver nitrate, using potassium chromate as the indicator, and reports it as salt […]
SOP: Determination of Soluble Solids (Cut-out Strength) in Canned Fruits by Refractometer
Food AnalysisCut-out strength is the soluble solids content of the covering syrup in a can of fruit, measured with a refractometer. It tells the laboratory whether the syrup meets the standard for that product. The reading is corrected to the standard temperature of 20 C, and nothing else is corrected for. Purpose To determine soluble […]
SOP: Examination of Internal Condition of Cans
Food AnalysisPrinciple After the can is emptied and washed, its internal surface is examined for corrosion, lacquer defects and seam faults, and the seam dimensions are measured; swollen cans receive a special seam examination. Procedure Once the cans are emptied and washed, look over the inside surface for corrosion, blistered or defective lacquer, pitting, scratches, […]
SOP: Determination of Fill of the Container
Food AnalysisPrinciple The fill of the container with food is found by measuring how far the food falls short of the top of the container: the water capacity of the container and the water remaining after drawing off to the food level are weighed, and the fill is expressed as a percentage. Apparatus required Weighing […]
SOP: Determination of Water Capacity of Containers
Food AnalysisPrinciple The water capacity of a container is the volume of distilled water at 20 °C which the sealed metal or glass container will hold when completely filled; it is found by weighing the empty container and the container filled with distilled water at 20 °C. Apparatus required Weighing balance Reagents a. Distilled water […]