Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

Food Analysis Methods Quiz

GIFSQ ID: ART-1013

What this quiz covers

Food analysis runs on separation and measurement, and this quiz opens inside the chromatograph. The mobile phase can be liquid or gas, the stationary phase supported on a solid can be solid or liquid, and a chromatogram plots time against concentration, with peak positions telling you which components are present. Raising the flow rate cuts longitudinal diffusion broadening, which is the B term of the van Deemter relationship, though faster flow also widens peaks through the mass transfer term, so the gain is partial rather than free. HPLC and UPLC differ mainly in particle size: UPLC uses sub-2-micron packings at very high pressure.

The techniques and instruments fill the middle of the set. Ninhydrin sprayed on paper to detect amino acids is paper chromatography, gradient, stepwise and zone elution all run on a column, TLC is inexpensive, portable and reliable, and the injector, column and detector are all system components. Solvent reservoirs, injection device, data acquisition and detector all belong to the liquid chromatography instrument, and DSC stands for Differential Scanning Calorimetry, which tracks heat flow against a reference as temperature is scanned.

Labels, indicators, and two pH anchors

Apparent density of cereal grains is measured with the single-kernel characterization system, iodine tracks starch conversion by its blue complex, coffee is commonly adulterated with chicory, potassium nitrite is E249 and karaya gum is E416. The two pH anchors close the set: 1 M NaOH is pH 14 and 1 M HCl is pH 0, mirror images of strong base and strong acid.

How to use this quiz

Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the correct choice in plain words, so a miss becomes a fact you keep. The ‘all of these’ options are often right here, but only when every item listed truly belongs, so check each one.

Food Analysis Methods Quiz
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

A short note: food analysis methods

Food analysis methods cover chromatography, thermal analysis and the numbers behind a separation. In chromatography the mobile phase can be liquid or gas, and the stationary phase supported on a solid can be solid or liquid. A chromatogram plots time against concentration, and peak positions on the time axis tell you which components are present.

A higher flow rate cuts longitudinal diffusion broadening. UPLC differs from HPLC in using smaller stationary-phase particles. Gradient and stepwise elution both run on a chromatography column. TLC is inexpensive, portable and reliable, and ninhydrin sprayed on paper to detect amino acids is classic paper chromatography. A liquid chromatography instrument has a solvent system, an injector and a detector, with data acquisition on the detection and control side.

DSC is short for Differential Scanning Calorimetry, which measures heat flow as a sample is heated or cooled. Apparent density of cereal grains comes from a single-kernel characterization system. Iodine tracks starch conversion, forming a deep blue complex with amylose. Coffee is often stretched with chicory, roasted root that resembles coffee. On labels, potassium nitrite is E249 and karaya gum is E416. 1 M NaOH has a pH of 14, and 1 M HCl has a pH of 0.

Practical takeaway: read peak position for identity, peak area for amount, and check the E-number before you trust a label.

Questions and answers

Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.

Question 1: When a chromatogram is used as the detector, the graph is plotted between time and what?

  • A. Quantity
  • B. Density
  • C. Specific gravity
  • D. Concentration

Correct answer: Concentration

When a chromatogram is used as the detector output, the graph is plotted between time and concentration. Time on the axis gives retention time, which identifies each component, and the detector response at each moment reflects the concentration of whatever is eluting then.

Question 2: Why would you raise the flow rate in chromatography?

  • A. To reduce mobile-phase mass transport broadening
  • B. To reduce stationary-phase mass transport broadening
  • C. To reduce eddy diffusion
  • D. To reduce longitudinal diffusion broadening

Correct answer: To reduce longitudinal diffusion broadening

Raising the flow rate reduces longitudinal diffusion broadening. In the van Deemter relationship the longitudinal diffusion term falls as flow velocity rises, because analytes spend less time diffusing along the column. Faster flow worsens the mass-transport terms, but the term it shrinks is longitudinal diffusion.

Question 3: What is the main difference between HPLC and UPLC?

  • A. HPLC is reverse-phase, UPLC is normal-phase
  • B. They use different mobile phases
  • C. They use different detectors
  • D. UPLC uses smaller stationary-phase particles

Correct answer: UPLC uses smaller stationary-phase particles

The main difference is that UPLC uses smaller stationary-phase particles : sub-2-micron packings run at very high pressure, versus the larger particles of conventional HPLC. Both can run reverse or normal phase, use the same kinds of mobile phases, and use the same detector types.

Question 4: When the stationary phase is supported on a solid, what can it be?

  • A. Liquid or gas
  • B. Solid or liquid
  • C. Solid only
  • D. Liquid only

Correct answer: Solid or liquid

When the stationary phase is supported on a solid, it can be solid or liquid : a liquid stationary phase coated onto a solid support gives partition chromatography, while the bare solid surface gives adsorption chromatography. It is not restricted to one physical state.

Question 5: Spraying ninhydrin on paper to detect amino acids is an example of which chromatography?

  • A. Column chromatography
  • B. Thin layer chromatography
  • C. Liquid chromatography
  • D. Paper chromatography

Correct answer: Paper chromatography

Spraying ninhydrin on paper to detect amino acids is the classic paper-chromatography experiment : ninhydrin reacts with amino acids to give the characteristic purple spots after separation. Column, thin-layer and liquid chromatography use different supports and detection setups for this analysis.

Question 6: What do peak positions on a chromatogram's time axis tell you?

  • A. Amount of each component
  • B. The components present
  • C. Column efficiency
  • D. Column resolution

Correct answer: The components present

Peak positions on the chromatogram's time axis tell you the components present : each compound has a characteristic retention time under given conditions, so the position identifies what it is. How much is present comes from peak area or height, not position.

Question 7: What can the mobile phase in chromatography be?

  • A. Solid or liquid
  • B. Gas only
  • C. Liquid or gas
  • D. Liquid only

Correct answer: Liquid or gas

The mobile phase in chromatography can be liquid or gas : liquid in liquid chromatography and gas in gas chromatography. It must flow to carry analytes through the system, so a solid can never serve as the mobile phase.

Question 8: Which of these run on a chromatography column?

  • A. Gradient-elution chromatography
  • B. Stepwise-elution chromatography
  • C. All of these
  • D. Zone chromatography

Correct answer: All of these

All of these run on a chromatography column : gradient elution, stepwise elution and zone chromatography are all elution modes performed on a packed or coated column. They differ in how the mobile phase composition changes, not in where the separation happens.

Question 9: Which of these are true of TLC?

  • A. All of these
  • B. Inexpensive
  • C. Portable
  • D. Reliable

Correct answer: All of these

All of these are true of TLC : it is inexpensive, portable and reliable, which is why it remains a workhorse for quick qualitative screening. No special instrumentation is needed beyond the coated plate and a developing chamber.

Question 10: Which of these are chromatography system components?

  • A. Column
  • B. All of these
  • C. Injector
  • D. Detector

Correct answer: All of these

All of these are chromatography system components : the injector introduces the sample, the column performs the separation, and the detector senses the eluting analytes. A working chromatograph needs every one of them.

Question 11: Which of these are parts of a liquid chromatography instrument?

  • A. Solvent reservoirs
  • B. Injection device
  • C. All of these
  • D. Column

Correct answer: All of these

All of these are parts of a liquid chromatography instrument : the solvent reservoirs hold the mobile phase, the injection device introduces the sample, and the column carries out the separation. Each is essential to the flow path.

Question 12: Which of these belong to the detection and control side of a liquid chromatography instrument?

  • A. Data acquisition
  • B. Solvent delivery system
  • C. Data acquisition and detector
  • D. Detector

Correct answer: Data acquisition and detector

The detection and control side is everything that senses the separation and manages the run: the detector converts eluting analytes into an electrical signal, and the data acquisition system records and processes that signal into the chromatogram. The solvent delivery system is the pump that pushes mobile phase through the column, so it belongs to the delivery side : meaning only data acquisition and the detector sit on the detection and control side.

Question 13: What does the analytical technique DSC stand for?

  • A. Differential Scanning Calorimetry
  • B. Direct Scanning Calorimetry
  • C. Dynamic Sample Combustion
  • D. Derived Spectrum Chromatography

Correct answer: Differential Scanning Calorimetry

DSC stands for Differential Scanning Calorimetry : the technique that measures heat flow into or out of a sample versus a reference as temperature is scanned, revealing melting, crystallization and denaturation transitions.

Question 14: What is apparent density of cereal grains measured with?

  • A. Single-kernel characterization system
  • B. Extensigraph
  • C. Farinograph
  • D. Butyrometer

Correct answer: Single-kernel characterization system

Apparent density of cereal grains is measured with the single-kernel characterization system, the only listed instrument that characterizes grain kernels themselves, measuring kernel weight, diameter, hardness and moisture. The extensigraph and farinograph measure dough rheology, and the butyrometer measures milk fat : none of them handles grain density.

Question 15: What indicator is used to track starch conversion?

  • A. Alpha-amylase
  • B. Beta-amylase
  • C. Diastase
  • D. Iodine

Correct answer: Iodine

Iodine is the indicator used to track starch conversion : it forms a deep blue complex with intact starch, and the fading of that color shows starch being broken down. Alpha-amylase, beta-amylase and diastase are the enzymes doing the conversion, not the indicator revealing it.

Question 16: What is coffee commonly adulterated with?

  • A. Sawdust
  • B. Ghee
  • C. Chicory
  • D. All of these

Correct answer: Chicory

Coffee is commonly adulterated with chicory : roasted chicory root resembles coffee in color and flavor, which is why it has been the classic coffee extender and adulterant. Sawdust and ghee are not typical coffee adulterants.

Question 17: Potassium nitrite is listed under which E-number on food packaging?

  • A. E250
  • B. E251
  • C. E249
  • D. E252

Correct answer: E249

Potassium nitrite is listed as E249 on food packaging. In the nitrite-nitrate series, E249 is potassium nitrite, E250 is sodium nitrite, E251 is sodium nitrate and E252 is potassium nitrate.

Question 18: If karaya gum appears on a label, which E-number identifies it?

  • A. E416
  • B. E415
  • C. E414
  • D. E413

Correct answer: E416

Karaya gum appears as E416 on labels. In the gum series, E413 is tragacanth, E414 is acacia, E415 is xanthan and E416 is karaya.

Question 19: What is the pH of 1 M NaOH?

  • A. 7
  • B. 10
  • C. 12
  • D. 14

Correct answer: 14

The pH of 1 M NaOH is 14 : a 1 molar hydroxide solution gives a hydroxide concentration of 1 M, so pOH is 0 and pH is 14. It is a strongly basic solution, far from neutral 7.

Question 20: What is the pH of 1 M HCl?

  • A. 7
  • B. 10
  • C. 0
  • D. 14

Correct answer: 0

The pH of 1 M HCl is 0 : a 1 molar strong acid gives a hydrogen ion concentration of 1 M, so pH is 0. It is a strongly acidic solution, the mirror image of 1 M NaOH.