Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

Analytical Techniques – Part 2

GIFSQ ID: ART-0807

What this quiz covers

Food analysis runs on instruments, and this quiz tests the second half of the analytical techniques set: the methods that separate, detect, and measure what is in a food. You will meet blotting, chromatography in several forms, spectroscopy, mass spectrometry, and the wet chemistry that still sits behind the instruments, from chemical oxygen demand to fat extraction with ether.

Twenty questions cover Southern blotting and the diode-array detector; reversed-phase HPLC and the Beer-Lambert law; AAS for lead in drinking water and GC-MS for dioxins; SDS-PAGE and carrier gases; mass-to-charge ratio; slow injection and resolution; ion-exchange resins and gel filtration; affinity chromatography; protein separation by charge, solubility, and size; tracking an energy-metabolism enzyme by its ATP synthesis rate; and ether as the fat-extraction solvent.

Concepts you will need

For each technique, ask three questions: what does it separate, what does it detect, and what does it measure. Chromatography separates, spectroscopy detects, and the two together identify. Once you can name the separation principle for each method, the instrument questions answer themselves.

How to use this quiz

You get 20 seconds per question and one attempt at each answer, so name the technique before you read the options. If a question names a detector or a column, picture the instrument first: the right answer is usually the one that matches how the instrument actually works. Then retake the quiz and check that the picture holds. When a question gives you a number, such as a wavelength range, check the units first: a wrong unit is the fastest way to pick the wrong option, and the right unit usually points straight at the right technique.

Analytical Techniques – Part 2
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

A short note: chromatography and protein separation

Analytical techniques part 2 covers chromatography, mass spectrometry and protein separation in food analysis. In reversed-phase HPLC a hydrophobic stationary phase pairs with a polar mobile phase, and the column is where separation happens. A diode-array detector records the full wavelength spectrum in one run. Helium is the standard GC carrier gas because it is inert, while oxygen is unsuitable because it is reactive.

Mass spectrometry separates ions by mass-to-charge ratio, and GC-MS pairs gas chromatography with mass spectrometry to monitor trace contaminants such as dioxins. Lead in drinking water is best measured by AAS. Slow injection of a large sample volume decreases resolution, because the sample spreads into a broad band at the column head.

Proteins are separated by size, charge or specific binding. Gel-filtration chromatography sorts molecules by size and shape through porous beads. Ion-exchange chromatography separates proteins by net charge, using resins that are polymeric networks carrying ionic functional groups. Affinity chromatography relies on specific binding: only the target protein sticks to its immobilized partner. SDS-PAGE is gel electrophoresis, not gas chromatography, and separates proteins by size after SDS denaturation. Southern blotting transfers DNA onto a nitrocellulose membrane for probing. Chemical oxygen demand is the oxygen needed to oxidize pollutants in water, and fat is estimated by extraction with ether.

Practical takeaway: pick the separation by the property that differs, size, charge or binding, and keep GC injections fast and small.

Questions and answers

Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.

Question 1: The transfer of DNA onto a nitrocellulose membrane is called which kind of blotting?

  • A. Western
  • B. Southern
  • C. Northern
  • D. Dot

Correct answer: Southern

Transferring DNA onto a nitrocellulose membrane for probing is Southern blotting : named for Edwin Southern, with Northern for RNA and Western for protein following the joke.

Question 2: A diode-array detector (DAD) with UV detection is advantageous because of what?

  • A. It picks one wavelength more precisely
  • B. It covers a range of wavelengths
  • C. It detects lower concentrations
  • D. It speeds up single-wavelength detection

Correct answer: It covers a range of wavelengths

A diode-array detector captures a whole spectrum of wavelengths at once, so one run yields full UV spectra and peak-purity checks instead of a single-wavelength trace.

Question 3: In reversed-phase HPLC, which phases are paired?

  • A. Hydrophilic stationary phase with polar mobile phase
  • B. Hydrophilic stationary phase with non-polar mobile phase
  • C. Hydrophobic stationary phase with polar mobile phase
  • D. Hydrophobic stationary phase with non-polar mobile phase

Correct answer: Hydrophobic stationary phase with polar mobile phase

Reversed-phase HPLC pairs a hydrophobic (non-polar) stationary phase with a polar mobile phase, so the least polar analytes stick longest : the reverse of normal-phase chromatography.

Question 4: Lead levels in drinking water are best determined using which technique?

  • A. HPLC
  • B. AAS
  • C. GC-MS
  • D. Capillary electrophoresis

Correct answer: AAS

Atomic absorption spectroscopy is the go-to for lead in drinking water because it measures the element itself at trace levels with minimal interference.

Question 5: Which technique is used for monitoring dioxin levels in the environment?

  • A. GC-MS
  • B. AES
  • C. AAS
  • D. TLC

Correct answer: GC-MS

Dioxins are volatile, fat-soluble trace contaminants, so gas chromatography, mass spectrometry : high separation plus definitive mass identification : is the standard monitoring technique.

Question 6: Which statement about the SDS-PAGE technique is INCORRECT?

  • A. It runs on gel-covered plates
  • B. SDS denatures the samples
  • C. It separates proteins
  • D. It is a type of gas chromatography

Correct answer: It is a type of gas chromatography

SDS-PAGE is a gel electrophoresis method that separates proteins by size after SDS denaturation; calling it a type of gas chromatography is the incorrect statement.

Question 7: The Beer-Lambert law gives a linear relationship with positive slope between which two quantities?

  • A. Wavelength and absorbance
  • B. Absorbance and concentration
  • C. Molar extinction coefficient and absorbance
  • D. Molar extinction coefficient and concentration

Correct answer: Absorbance and concentration

The Beer, Lambert law says absorbance rises in a straight line with concentration : a linear, positive-slope plot that makes absorbance a direct measure of how much analyte is present.

Question 8: Which substance is commonly used as the mobile phase in GC-MS?

  • A. Helium
  • B. Air
  • C. Acetonitrile
  • D. Water

Correct answer: Helium

Helium is the standard GC-MS mobile (carrier) phase: inert, so it never reacts with analytes, and light enough to sweep them cleanly through the column into the mass spectrometer.

Question 9: Mass spectrometers separate isotopes based on their what?

  • A. Mass
  • B. Electric charge
  • C. Mass divided by electric charge
  • D. Atomic number

Correct answer: Mass divided by electric charge

A mass spectrometer separates ions by their mass-to-charge ratio (m/z) : neither mass nor charge alone determines the flight path or trajectory.

Question 10: Which gas is unsuitable for use as a GC carrier gas?

  • A. Nitrogen
  • B. Helium
  • C. Oxygen
  • D. Hydrogen

Correct answer: Oxygen

Oxygen is unsuitable as a GC carrier gas because it is reactive and would oxidize analytes, the stationary phase, and hot metal parts; nitrogen, helium, and hydrogen are the inert choices.

Question 11: Slow injection of a large sample volume results in what?

  • A. Increased resolution
  • B. Decreased resolution
  • C. Non-linear detector response
  • D. Faster analysis

Correct answer: Decreased resolution

A slow, large-volume injection smears the sample into a wide band at the column head, and that broad starting band degrades resolution.

Question 12: An ion-exchange resin is composed of which of these?

  • A. Polymeric network
  • B. Ionic functional groups
  • C. Counter-ions
  • D. All of these

Correct answer: All of these

An ion-exchange resin is a polymeric network carrying ionic functional groups with their counter-ions : all three parts working together.

Question 13: The chemical oxygen demand (COD) measures which of these?

  • A. Oxygen needed for microbial growth
  • B. Oxygen needed to oxidize pollutants
  • C. Oxygen needed to oxidize calcium
  • D. Dissolved oxygen content

Correct answer: Oxygen needed to oxidize pollutants

Chemical oxygen demand measures the oxygen needed to chemically oxidize the pollutants in water : a gauge of total oxidizable contamination, not of microbial growth or dissolved oxygen itself.

Question 14: In ion-exchange chromatography, proteins are separated on the basis of their what?

  • A. Net charge
  • B. Size
  • C. Shape
  • D. Hydrophobicity

Correct answer: Net charge

Ion-exchange chromatography separates proteins by net charge: proteins bind the oppositely charged resin and release as salt or pH gradients shift.

Question 15: Which of these may be added to stabilize a protein after yeast cell disruption?

  • A. Sodium chloride
  • B. Protease inhibitor
  • C. AMP
  • D. All of these

Correct answer: All of these

After yeast disruption, adding sodium chloride for ionic stability, a protease inhibitor to stop proteolysis, and AMP as an allosteric stabilizer can each help : so all three may be used.

Question 16: Gel-filtration chromatography separates molecules on the basis of what?

  • A. Size and shape, using porous beads
  • B. Size only, using porous beads
  • C. Shape only, using porous beads
  • D. Charge, using porous beads

Correct answer: Size and shape, using porous beads

Gel-filtration (size-exclusion) chromatography sorts molecules by size and shape as they navigate porous beads : large molecules bypass the pores and elute first.

Question 17: Affinity chromatography is based on which principle?

  • A. Specific binding of a protein to another molecule
  • B. Protein-protein interaction
  • C. Protein-carbohydrate interaction
  • D. Size exclusion

Correct answer: Specific binding of a protein to another molecule

Affinity chromatography works on specific binding: the target protein alone locks onto its immobilized ligand while everything else washes through.

Question 18: Protein separation can be carried out on the basis of which of these?

  • A. Net charge
  • B. Solubility in salt solutions
  • C. Size or mass
  • D. All of these

Correct answer: All of these

Protein separation can exploit net charge (ion exchange), solubility in salt solutions (salting out), and size or mass (gel filtration) : all of these principles are in routine use.

Question 19: When the target protein is an enzyme of energy metabolism, the best way to locate it across purification steps is to measure which of these?

  • A. Rate of ATP synthesis
  • B. Changes in refractive index
  • C. UV absorption
  • D. Mass spectrometry

Correct answer: Rate of ATP synthesis

When the target is an enzyme of energy metabolism, such as an ATPase, its catalytic activity : the rate of ATP synthesis : is the specific signal that pinpoints which fractions hold it across purification steps.

Question 20: Which solvent is used for the estimation of fat content?

  • A. Hydrochloric acid
  • B. Sodium hydroxide
  • C. Amylase
  • D. Ether

Correct answer: Ether

Fat content is estimated by extracting the lipid with ether (e.g., in the Soxhlet method), since ether dissolves fats while leaving proteins and carbohydrates behind.