Physical Analysis
SOP: Measurement of Texture Using the Instron Universal Testing Machine
Principle The Instron universal testing machine drives a moving crosshead vertically at selected speeds (0.05 to 50 cm/min) while a strain-gauge load system records the force; the recorder chart and the crosshead are synchronously driven, so the trace is a force-distance curve from which firmness, toughness, fracturability and texture-profile parameters are read. With suitable fixtures […]
SOP: Texture Profile Analysis Using the General Foods Texturometer
Principle The General Foods Texturometer imitates mastication: an articulator drives a plunger up and down on the sample for two successive cycles (two “bites”), and the force-time curve so obtained yields the texture profile parameters: hardness, cohesiveness, elasticity (springiness), adhesiveness, fracturability (brittleness), gumminess and chewiness: all derived from the same curve. A standard sponge rubber […]
SOP: Determination of Maturity of French Beans by Shear Test
Principle As French (green) beans mature they become fibrous and the force required to shear them increases. Using a single shear blade (similar to the Warner-Bratzler shear blade), the force required to shear beans placed edgewise and flat is measured; in tender beans the edgewise force is generally more than the flat-position force, and the […]
SOP: Determination of Maturity of Peas Using a Tenderometer
Principle As peas mature they become tougher and offer more resistance to cutting. In the texturometer for peas, a grid of blades is rotated at a constant speed through a second grid of peas so that the force on the second grid is counter-balanced by a pendulum; as the peas are cut by the blades, […]
SOP: Determination of Fruit Firmness Using a Hand Pressure Tester
Principle The Magness-Taylor pressure tester measures the maximum force required to push a cylindrical metal probe into the flesh of a fruit to a given depth; the force recorded indicates the firmness of the fruit and is used to determine softening during maturity and ripening. The larger (7/16 inch) punch is used on softer materials […]
SOP: Determination of Viscosity Using the Stormer Viscometer
Principle The Stormer viscometer measures consistency or viscosity by the time required for a rotor, driven by a falling weight, to make 100 revolutions in the sample. The number of seconds for 100 revolutions, measured against the time for the same number of revolutions in a standard liquid under identical conditions, gives the relative viscosity; […]
SOP: Determination of Consistency Using the Adams Consistometer
Principle The Adams consistometer overcomes the limitations of the Bostwick consistometer for cream style corn (small capacity, arc-shaped flow front, flow in one direction only) by measuring the unrestrained flow of a larger mass of sample in all directions over a disc engraved with concentric circles. A hollow truncated cone holding the sample is seated […]
SOP: Determination of Consistency by the Efflux-Tube Viscometer
Principle Efflux-tube viscometers measure the time necessary for a fixed quantity of fluid to pass through an orifice or capillary under standard pressure. In the specially designed efflux-tube viscometer used for tomato puree, the sample is drawn up the tube by vacuum and then allowed to flow out; the time of flow between two marks […]
SOP: Determination of Consistency Using the Bostwick Consistometer
Principle The Bostwick consistometer measures the consistency of viscous foods such as tomato ketchup and sauce on the theory that the length of flow of the released product along a channel is proportional to its consistency. A portion of the sample is held behind a triggered gate at one end of a channel; when the […]
SOP: Determination of Consistency Constants Using a Brookfield Viscometer
Principle The Brookfield viscometer measures the torque on a rotating spindle (bob) immersed in the product; from the torque–speed relationship the fundamental consistency constants of a non-Newtonian product are obtained: the flow behaviour index (n), the consistency coefficient (K) and, where present, the yield stress (C). The drag on the ends of the spindle is […]
SOP: Determination of Consistency Constants Using a Tube Viscometer
Principle Fruit purees and juices are non-Newtonian fluids: their resistance to flow changes with the rate of shear, so a single viscosity figure does not describe them. In a tube viscometer, the product is forced through a capillary tube under measured pressure and the rate of flow is recorded at several pressures. From the relationship […]
SOP: Measurement of Colour of Transparent Products by Transmittance
Principle The methods for measuring colour by reflectance locate the colour of any food in colour space by determining the three attributes of colour. For products which are transparent: like lime juice cordial and clarified apple, guava or grape juice: or for a product which can be made transparent by extraction with suitable solvents and […]
SOP: Measurement of Colour with the Photovolt Reflectance Meter
Principle The Photovolt reflectance meter is a photoelectric tricolorimeter that makes use of three tristimulus filters: amber, green and blue. Evaluation of the colour of a sample involves three measurements, one with each filter, and the trichromatic coefficients X, Y and Z are computed from the reflectance values obtained. These instruments measure diffuse reflectance. Apparatus […]
SOP: Measurement of Colour and Colour Difference with the Hunter Colour Meter
Principle Photoelectric tricolorimeters make use of three filters which have spectral sensitivity curves similar to the spectral distribution curves of the CIE reference stimuli X, Y and Z. Evaluation of the colour of a sample involves three measurements using each filter. The Hunter colour and colour-difference meter is one of the most successful tricolorimetric systems […]
SOP: Determination of Tristimulus Values by the Selected Ordinate Method
Principle Reduction of spectrophotometric data to the tristimulus values X, Y and Z is based on Grassmann’s laws. In the weighted ordinate method, the spectrum wavelengths are chosen at uniform intervals. In the selected ordinate method, instead, the intervals of spectrum selected correspond to uniform increments of each primary (X, Y or Z) in the […]
SOP: Determination of Tristimulus Values by the Weighted Ordinate Method
Principle A spectrophotometric curve relating wavelength and intensity through the visible part of the spectrum (approximately 380–770 nm) gives a complete physical specification of colour and makes it possible to calculate the CIE tristimulus values X, Y and Z. Reduction of spectrophotometric data to the tristimulus values X, Y and Z is based on Grassman’s […]
SOP: Measurement of Colour with the Lovibond Tintometer
Principle The Lovibond tintometer is a subtractive colorimeter based on direct observation of an illuminated sample through a viewing tube. The instrument is provided with sets of red, yellow and blue glass slides to be used as permanent standards. The slides form an evenly graded series from very light tints (0) to deep colours (20), […]
SOP: Measurement of Colour by Disc Colorimetry
Principle Disc colorimetry is an additive system based on the use of coloured discs. The discs have radial slits so that a number of them may be slipped together with varying portions of each showing; the discs are spun on a spindle at about 2,700 rpm so that the colours merge into a single hue […]
SOP: Colour Matching by the Maerz and Paul Colour Dictionary Method
Principle In the visual matching of the colour of food against standard colours, the sample is compared directly with printed colour standards. The colour dictionary of Maerz and Paul is the most commonly used; it consists of 56 charts in which seven main groups of hues are presented in spectral order, each group having 8 […]
SOP: Selection of Filters for Colorimetric Measurements
Principle Optical filters are used in colorimeters (absorptiometers) for isolating a desired spectral region. They consist of coloured glass or coloured gelatin coated on glass and possess the property of selectively transmitting light from a specified region of the spectrum, the other regions being absorbed. The ideal way of selecting a filter for use with […]
SOP: Determination of Shelf-life of Packaged Foods by the Half-Value Period Method
Principle The shelf-life of a packaged food depends on (i) the reactivity of the food with deteriorating influences and (ii) the capacity of the package to protect the food from these influences. Next to microorganisms, oxygen is the most destructive agent; next in importance is the sensitivity of the food to storage atmosphere and changes […]
SOP: Determination of Equilibrium Relative Humidity by the Graphical Interpolation Method
Principle The graphical interpolation method is based on the principle that the rate of gain or loss of moisture of a product, at any given initial moisture content and atmospheric relative humidity, increases with increasing difference between the atmospheric and the product vapour pressures. The duration of exposure is held constant in a true equilibrium […]
SOP: Determination of Equilibrium Relative Humidity by Wink’s Weight Equilibrium Method
Principle A product is in equilibrium with its environment when the rate of moisture loss from the product to the surrounding atmosphere equals the rate of moisture gained from the atmosphere. The relative humidity at which the substance will neither gain nor lose moisture under given temperature conditions is the equilibrium relative humidity (ERH). In […]
SOP: Determination of Grease Resistance by Transudation Time
Principle Grease resistance of a packaging material is compared by the transudation time: coloured turpentine is applied to sand spread over the test specimen, and the elapsed time in seconds between the addition of the turpentine and the appearance of the first definite red stain on a paper underneath is noted. The test gives an […]