SOP: Construction of Lethal-Rate Paper and Calculation of Sterilizing Value

October 15, 2026

Principle Schultz and Olson’s special coordinate (lethal-rate) paper removes the need to calculate the TDT at every temperature: the temperature scale is replaced by lethal-rate spacing, so the lethality curve is plotted directly from the heat penetration data, and the F value of the process is calculated from the area under the curve with a […]

Read More

SOP: Evaluation of Thermal Process by the General Method

October 15, 2026

Principle The General Method (also called the Graphical Method), developed by Bigelow et al., integrates graphically the lethal effects of all the time-temperature relationships existing at the cold point during heating and cooling. The rate of destruction of an organism per minute at any temperature is the reciprocal of the time in minutes required to […]

Read More

SOP: Determination of Heat Penetration in Canned Foods

October 15, 2026

Principle Adequate thermal process calculation requires accurate measurement of heating and cooling at the cold point of the container during a retort run. Thermocouples fixed at the cold point record the container temperatures throughout heating and cooling; the resulting heat penetration curve, together with the product, container and retort data, is the basis of all […]

Read More

SOP: Determination of the Cold Point of a Container

October 15, 2026

Principle When a can is processed, all points within it are not at the same temperature. The zone of slowest heating: the cold point: is the zone most difficult to sterilize. When heating is by convection the cold point lies on the vertical axis near the bottom of the container; when heating is by conduction […]

Read More

SOP: Correction for Heating Lag in Thermal Inactivation Time Determination

October 15, 2026

Principle The thermal inactivation time (TIT) as measured needs correction for the delay in bringing the contents of the tube to the temperature of the water bath. The extent of inactivation during the come-up period is calculated by the graphical method of Bigelow et al., as developed by Nath and Ranganna: the inactivation rate (1/TIT) […]

Read More

SOP: Determination of Thermal Inactivation Time of Peroxidase

October 15, 2026

Principle Peroxidase is the most heat-resistant of the enzyme systems in fruits and is used as the index organism-equivalent for thermal process schedules based on enzyme inactivation. The thermal inactivation time (TIT): the minimum heating time at a given temperature at which peroxidase activity disappears: is determined by heating tubes of the prepared material at […]

Read More

SOP: Preparation of Material for Thermal Inactivation Time Determination of Enzymes

October 15, 2026

Principle For acid fruit products the thermal process is often based on the inactivation of heat-resistant enzymes (peroxidase, pectinesterase, polyphenoloxidase), which are more heat-resistant than the spoilage microorganisms. The test material must reproduce the product as canned: same pulp, same syrup strength and ratio, same pH and °Brix: so that the measured thermal inactivation times […]

Read More

SOP: Conversion of Thermal Death Time Data to Classical F and D Values

October 15, 2026

Principle F values reported in the literature are often based on different initial numbers of cells and are therefore not comparable; D values are independent of initial numbers and can be compared directly. Because Esty and Meyer’s classical data for Cl. botulinum (a preparation containing 6 × 10¹⁰ spores killed at 250 °F in 2.78 […]

Read More

SOP: Plotting of Thermal Death Time and Thermal Resistance Curves

October 15, 2026

Principle When the decimal reduction times (D values) determined at several temperatures are plotted on semi-log paper against temperature, a straight line is obtained: the thermal resistance curve (also called the phantom thermal death time curve). Its slope, measured as the number of °F required for the curve to pass over one log cycle, equals […]

Read More

SOP: Determination of Decimal Reduction Time (D Value)

October 15, 2026

Principle The death rate of microorganisms when exposed to heat follows a logarithmic course: equal percentages of the surviving cells die in each successive unit of time. The decimal reduction time D is the time required to reduce the bacterial population by 90% at a given temperature. Unlike the TDT, which uses only the two […]

Read More

SOP: Examination of Heavy Extraneous Materials by Reverse Flotation

October 15, 2026

Principle Unlike insect fragments and rodent hairs, fly eggs, larvae, maggots, some nematodes, heavy rodent excreta (pellets), sand and similar materials do not float in the oil layer but settle down. The flotation procedure is therefore carried out in reverse: when petrol is mixed vigorously with the plant material and allowed to separate, most of […]

Read More

SOP: Separation and Counting of Insect Fragments by Oil Flotation

October 15, 2026

Principle Insects, insect fragments and rodent hairs are often lighter than food and may be floated out in liquids heavier than water; mammalian hairs behave in the same way as the insect cuticle and may be separated by oil flotation. With the exception of fly larvae and maggots, which are not wetted by oils, other […]

Read More

SOP: Separation of Sand, Soil and Glass from Food Products

October 15, 2026

Sand, soil, glass and similar heavy foreign materials are separated from the food by sedimentation in a liquid of specific gravity near 1.49: the dense fragments settle out while the plant tissue tends to rise. In spices, sand, soil, stems and similar heavy matter may be separated by dry sieving instead. Purpose To separate sand, […]

Read More

SOP: Direct Microscopic Count of Bacteria in Tomato Products

October 15, 2026

Principle High bacterial counts indicate secondary spoilage that may have occurred in the factory through breakdown or careless cleaning methods. The rod-shaped bacteria are counted directly under the microscope on the same mount as that prepared for yeasts and spores, and the count per unit volume is computed from the known area examined and the […]

Read More

SOP: Direct Microscopic Count of Yeasts and Spores in Tomato Products

October 15, 2026

Principle High counts of yeasts and spores indicate secondary spoilage that may have occurred in the factory through breakdown or careless cleaning methods. Since specifications have been laid down for their counts in tomato products, the organisms are counted directly under the microscope in a blood counting cell after diluting the sample with water. Yeast […]

Read More

SOP: Mould Counting in Fruit and Vegetable Products other than Tomato Products

October 15, 2026

Principle Mould filaments in a finished product indicate food decomposition before processing, whether from plant disease, secondary invasion of injured raw material, physiological disorders, or growth from inadequate cleaning of machinery (growth of Oospora species particularly indicates a plant clean-up is needed). The Howard mould counting procedure developed for tomato products is applied to other […]

Read More

SOP: Examination of Rot in Canned Tomatoes

October 15, 2026

Principle Rotten portions in canned tomatoes are detected by individually inspecting the drained tomatoes, and by counting mould in the pulped tomato and in the drained juice using the Howard cell, since mould filaments are a reliable index of rotten raw material having gone into the can. Apparatus required Suitable sieve (for draining the contents) […]

Read More

SOP: Counting of Rot Fragments in Tomato Products

October 15, 2026

Principle Rot fragments are fragments of tomato tissue that carry attached mould filaments; in some cases they show up as nearly solid clumps of mould. In this method the tissue is stained with crystal violet, the surplus pulp is rinsed away through a sieve, and the stained rot fragments are then counted under the microscope […]

Read More

SOP: Mould Counting in Tomato Products by the Howard Method

October 15, 2026

Principle Mould growth breaks down fruit and vegetable tissue to form rot, so the presence of mould filaments in a finished product is a reliable index of rotten raw material having gone into manufacture. Because tomato products are comminuted and cooked during manufacture, visual inspection and the plate count (which reveals only living microorganisms) are […]

Read More

SOP: Determination of Weight-to-Length Ratio of French Beans

October 15, 2026

As a French bean grows, its weight rises faster than its length, and its tenderness, appearance and flavour change with it. Ten physico-chemical characteristics were studied during growth in the Burpee stringless variety, and the weight-to-length ratio was found to track the sensory characteristics closely. One simple measurement therefore says a lot about maturity. This […]

Read More

SOP: Maturity Grading of Peas and Lima Beans by Brine Density

October 15, 2026

Principle As peas and lima beans mature, their density increases; shelled peas are blanched and floated in brines of stated density, and the proportion sinking in each brine is counted. The United States Standards for grades of canned peas fix, for each grade, the maximum percentages sinking in the prescribed salt solutions (11%, 13%, 13½% […]

Read More

SOP: Determination of Succulence Using a Succulometer

October 15, 2026

Principle Succulence or juiciness is associated with the moisture content of the product. In the succulometer, a weighed charge of the product is pressed in a cylindrical cell under a fixed pressure for a fixed time, and the volume of juice expressed is measured; the volume of expressed juice gives an indication of the succulence […]

Read More