Heat moves in three ways, and every food process uses all three at once. Conduction carries heat through the solid wall of a pan or a slab of food, following Fourier’s law: flux proportional to the temperature gradient, with thermal conductivity as the constant. Convection carries heat between a surface and a moving fluid, following Newton’s law of cooling, and radiation carries it across empty space from hot oven walls, following the Stefan-Boltzmann law, scaling with the fourth power of absolute temperature. This quiz starts with those three laws and the numbers that organize them: the Nusselt number for the heat transfer coefficient, Reynolds and Prandtl inside its correlations, and the Biot number that tells you when a small metal sphere warms almost uniformly, the lumped capacitance case.

From the laws the set moves to the equipment: plate exchangers whose corrugated plates trip turbulence for viscous sauces, counter current flow that holds the log mean temperature difference high, regeneration sections that recover heat from hot product to preheat cold feed, and fouling, the scale and protein deposits that add thermal resistance and drag the overall coefficient U down. The numerical questions are worked from the same formulas: Q equals hA times delta T, Q equals UA times LMTD, and the series resistance sum that gives 1 over U.

Follow the heat, step by step

Every calculation in this quiz is a walk along the heat path: from the hot fluid, through the wall, into the cold fluid, with a resistance at each step. Add the resistances, find the bottleneck, and the numbers follow.

How to use this quiz

Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the sections, numbers and definitions a Loksewa candidate is expected to know by heart.

Heat Transfer Quiz
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

A short note: heat transfer, Newton's law and the Nusselt number

Heat transfer moves by conduction, convection, and radiation. Fourier's law: conductive flux is proportional to the temperature gradient. Newton's law of cooling: convective flux is proportional to the temperature difference. Natural convection runs on buoyancy; forced convection uses a fan or pump. Radiation grows with absolute temperature to the fourth power. Emissivity, 0 to 1, measures how well a surface radiates.

Boiling and condensation give much higher h, since phase change moves latent heat. Turbulence raises h by thinning the thermal boundary layer. Fouling adds thermal resistance and lowers U. For a plane wall, 1/U equals 1/h1 plus thickness/k plus 1/h2. A thin stainless-steel wall beats a thick polymer wall. A small, conductive sphere has a Biot number well below 0.1. At 220 °C, oven radiation browns the crust.

Counter-current flow gives the highest LMTD. Hot 90 °C, cold 20 to 60 °C: LMTD is 47 °C. Water at 80 °C over a plate at 20 °C, h 500, area 0.5: 15,000 W. U 2000, area 1, LMTD 40 °C: 80 kW. A food slab, k 0.5, area 0.02, 0.1 m thick, faces 100 and 20 °C: 8 W. Plate exchangers suit viscous foods: corrugated plates promote turbulence. The Nusselt number, Nu = hL/k, gives the dimensionless heat transfer coefficient. Regeneration recovers heat from hot product to preheat incoming cold feed.

Check the mode, then the resistance.

Questions and answers

Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.

Question 1: A small metal sphere dropped into a hot bath warms almost uniformly throughout. Which model describes its temperature history?

  • A. Radiation only
  • B. Unsteady-state conduction with negligible internal resistance
  • C. Steady-state conduction
  • D. Adiabatic compression

Correct answer: Unsteady-state conduction with negligible internal resistance

A small, highly conductive sphere has a tiny Biot number (Bi = hL_c/k well below 0.1), so conduction inside it is fast compared with convection at its surface and internal temperature gradients are negligible : the whole body warms nearly uniformly. Its temperature history follows the lumped-capacitance model, an unsteady-state analysis with negligible internal resistance, giving a simple exponential approach to the bath temperature. Steady-state conduction cannot describe it because temperatures are changing with time.

Question 2: In a baking oven at 220°C, which mechanism contributes strongly to crust browning?

  • A. Thermal radiation from the hot oven walls and elements
  • B. Conduction through the tray
  • C. Mass transfer
  • D. Convection from the air

Correct answer: Thermal radiation from the hot oven walls and elements

At 220 °C the oven walls and heating elements emit strongly, and thermal radiation : which scales with the fourth power of absolute temperature per the Stefan, Boltzmann law : delivers a large radiant flux to the product surface, driving Maillard browning and caramelization of the crust. Conduction through the tray and convection from the air also heat the product, but radiation is the dominant browning contributor at these temperatures.

Question 3: Which law relates convective heat transfer to the temperature difference between a surface and the surrounding fluid?

  • A. Fourier's law
  • B. Dalton's law
  • C. Kirchhoff's law
  • D. Newton's law of cooling

Correct answer: Newton's law of cooling

Newton's law of cooling states that the convective heat flux is proportional to the temperature difference between a surface and the surrounding fluid: q = hA(T_s − T_∞). Fourier's law governs conduction, Dalton's law governs gas partial pressures, and Kirchhoff's law governs radiation exchange : each law belongs to its own mechanism.

Question 4: Why is the heat transfer coefficient during boiling or condensation so high?

  • A. It is lower than natural convection
  • B. It equals the liquid's thermal conductivity
  • C. It is much higher than single-phase convection because phase change absorbs/releases latent heat
  • D. It cannot be quantified

Correct answer: It is much higher than single-phase convection because phase change absorbs/releases latent heat

During boiling or condensation, enormous energy moves as latent heat at nearly constant temperature, so the effective heat transfer coefficient is orders of magnitude higher than single-phase convection : typically thousands to tens of thousands of W/m²·°C. It is very much quantifiable: boiling and condensation correlations are standard engineering practice. It is not lower than natural convection.

Question 5: Which flow arrangement in a heat exchanger gives the highest log mean temperature difference?

  • A. They are always equal
  • B. Co-current, because fluids enter together
  • C. Counter-current, because it maintains a larger mean temperature difference
  • D. Cross-flow is always best

Correct answer: Counter-current, because it maintains a larger mean temperature difference

In counter-current flow the hot and cold streams move in opposite directions, so the temperature difference between them stays relatively uniform along the exchanger instead of collapsing toward the outlet as in co-current flow. That maintains a larger log mean temperature difference, and since Q = UA·LMTD, more heat transfers for the same area. Cross-flow falls between the two.

Question 6: What distinguishes natural convection from forced convection?

  • A. They are identical mechanisms
  • B. Natural convection uses a fan
  • C. Natural convection is driven by buoyancy forces from density differences
  • D. Forced convection needs no energy input

Correct answer: Natural convection is driven by buoyancy forces from density differences

Natural convection is driven by buoyancy: fluid heated at a surface becomes less dense and rises, setting up flow with no fan or pump. Forced convection uses mechanical energy : a fan, pump, or agitator : to move the fluid. The two are distinct mechanisms, and forced convection always requires energy input.

Question 7: Which heat-exchanger type is most common for heating viscous food fluids because its corrugated plates promote turbulence?

  • A. Double-pipe
  • B. Finned tube
  • C. Shell-and-tube
  • D. Plate heat exchanger

Correct answer: Plate heat exchanger

Corrugated plates trip turbulence even at low Reynolds numbers, giving high heat transfer coefficients for viscous pastes, sauces, and dairy products : which is why the plate heat exchanger is the industry standard for heating viscous food fluids. Double-pipe and shell-and-tube exchangers are common duties too, but their smooth passages do not promote turbulence the same way at low flow rates.

Question 8: Which surface property controls how strongly a food surface radiates heat in an oven?

  • A. Reflectivity only
  • B. Absorptivity only
  • C. Thermal diffusivity
  • D. Emissivity

Correct answer: Emissivity

Emissivity (0 to 1) measures how effectively a surface emits thermal radiation relative to a blackbody, and it is the surface property in the Stefan, Boltzmann equation governing emission. Reflectivity and absorptivity describe incoming radiation, while thermal diffusivity governs how fast temperature waves propagate by conduction : a different phenomenon.

Question 9: Which dimensionless number is used in correlations to estimate the convective heat transfer coefficient?

  • A. Grashof number
  • B. Prandtl number
  • C. Reynolds number
  • D. Nusselt number

Correct answer: Nusselt number

The Nusselt number (Nu = hL/k) is the dimensionless heat transfer coefficient, and correlations of the form Nu = C·Re^m·Pr^n are how engineers estimate h from flow conditions. Reynolds and Prandtl numbers appear inside those correlations, and Grashof governs natural-convection flows : but Nusselt is the number that yields h.

Question 10: Why does fouling on heat-exchanger surfaces matter for thermal performance?

  • A. It improves heat transfer
  • B. It has no effect
  • C. It adds thermal resistance, lowering the overall coefficient U
  • D. It only affects pressure drop

Correct answer: It adds thermal resistance, lowering the overall coefficient U

Fouling : scale, protein deposits, biofilm : on exchanger walls adds a conduction resistance in series with the wall, so the overall coefficient U falls and more area or temperature difference is needed for the same duty. Fouling never improves heat transfer. It also raises pressure drop, but the thermal penalty is the added resistance.

Question 11: For a plane wall separating two fluids, how is the overall heat transfer coefficient U related to the film coefficients and wall conduction?

  • A. 1/U equals 1/h₁ plus Δx/k plus 1/h₂
  • B. U equals h₁ plus h₂
  • C. U equals k/Δx alone
  • D. U equals h₁ times h₂

Correct answer: 1/U equals 1/h₁ plus Δx/k plus 1/h₂

Resistances in series add: the total resistance is the convective resistance on each side (1/h₁ and 1/h₂) plus the wall's conductive resistance (thickness divided by conductivity, Δx/k), and U is the reciprocal of that total : 1/U = 1/h₁ + Δx/k + 1/h₂. U is not a sum or product of the individual coefficients.

Question 12: In a heat exchanger, the hot fluid stays at 90°C while the cold fluid warms from 20°C to 60°C. What is the log mean temperature difference?

  • A. 50°C
  • B. 60°C
  • C. 47°C
  • D. 35°C

Correct answer: 47°C

The end temperature differences are ΔT₁ = 90 − 20 = 70 °C and ΔT₂ = 90 − 60 = 30 °C. LMTD = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (70 − 30)/ln(70/30) = 40/0.847 ≈ 47.2 °C. The arithmetic mean (50 °C) overestimates because the temperature profile along the exchanger is logarithmic, not linear.

Question 13: Hot water at 80°C flows over a plate at 20°C with h = 500 W/m²·°C and area 0.5 m². What is the convective heat transfer rate?

  • A. 15,000 W
  • B. 30,000 W
  • C. 7,500 W
  • D. 1,500 W

Correct answer: 15,000 W

Newton's law of cooling gives q = hAΔT = 500 W/m²·°C × 0.5 m² × (80 − 20) °C = 500 × 0.5 × 60 = 15,000 W. The 1,500 W distractor comes from using a 6 °C difference instead of 60 °C.

Question 14: What is the purpose of a regeneration section in a continuous heating system?

  • A. It reduces the flow rate
  • B. It recovers heat from the hot product to preheat the incoming cold feed, saving energy
  • C. It increases the LMTD
  • D. It sterilizes the product

Correct answer: It recovers heat from the hot product to preheat the incoming cold feed, saving energy

In continuous heating systems such as HTST pasteurization, the regeneration section passes hot treated product against incoming cold feed, recovering most of the heating energy instead of dumping it to cooling water : a major energy saving. It does not sterilize the product; the holding tube at temperature does that.

Question 15: A heat exchanger with U = 2000 W/m²·°C, area 1 m² and LMTD 40°C transfers how much heat?

  • A. 40 kW
  • B. 80 kW
  • C. 160 kW
  • D. 8 kW

Correct answer: 80 kW

Q = U·A·LMTD = 2000 W/m²·°C × 1 m² × 40 °C = 80,000 W = 80 kW. The 8 kW distractor comes from dropping a factor of ten in the multiplication.

Question 16: Which law states that the conductive heat flux through a material is proportional to the temperature gradient?

  • A. Fick's law
  • B. Fourier's law
  • C. Newton's law of cooling
  • D. Stefan, Boltzmann law

Correct answer: Fourier's law

Fourier's law states that the conductive heat flux through a material is proportional to the temperature gradient: q = −k·dT/dx, with thermal conductivity k as the constant. Fick's law is the mass-transfer analog, Newton's law of cooling covers convection, and the Stefan, Boltzmann law covers radiation.

Question 17: How does increasing turbulence in the fluid affect the convective heat transfer coefficient?

  • A. It increases h by thinning the thermal boundary layer
  • B. It only raises pressure drop
  • C. It decreases h
  • D. It has no effect

Correct answer: It increases h by thinning the thermal boundary layer

Increasing turbulence thins the thermal boundary layer clinging to the wall, which steepens the temperature gradient at the surface and raises the convective heat transfer coefficient h. Pressure drop rises as well, but the heat-transfer effect is the increase in h : turbulence never decreases it.

Question 18: A slab of food (k = 0.5 W/m·°C) has area 0.02 m² and thickness 0.1 m, with faces at 100°C and 20°C. What is the steady conductive heat flow?

  • A. 8 W
  • B. 16 W
  • C. 80 W
  • D. 4 W

Correct answer: 8 W

Fourier's law for a plane slab gives q = kAΔT/Δx = 0.5 W/m·°C × 0.02 m² × (100 − 20) °C / 0.1 m = 0.5 × 0.02 × 800 = 8 W. The 80 W distractor comes from forgetting to divide by the 0.1 m thickness.

Question 19: How can the conductive resistance of a heat-exchanger wall be minimized?

  • A. Use thicker walls
  • B. Use a thin stainless-steel wall instead of a thick insulating polymer
  • C. Reduce the flow rate
  • D. Increase fouling

Correct answer: Use a thin stainless-steel wall instead of a thick insulating polymer

Conductive resistance of a wall is thickness divided by conductivity (Δx/k), so it is minimized with a thin wall of a high-conductivity material : a thin stainless-steel wall : rather than a thick wall of an insulating polymer. Thicker walls, lower conductivity, and added fouling all increase resistance, the opposite of what is wanted.

Question 20: How does radiative heat transfer scale with temperature?

  • A. It scales linearly with ΔT
  • B. It scales with the square of ΔT
  • C. It does not change with temperature
  • D. It scales with the fourth power of absolute temperature

Correct answer: It scales with the fourth power of absolute temperature

The Stefan, Boltzmann law (q = εσT⁴) makes emitted thermal radiation proportional to the fourth power of absolute temperature : so a modest temperature rise produces a huge increase in radiant flux. Linear or square scaling understates it badly, and radiation certainly changes with temperature.