Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

Food Technology Loksewa – Sampling

GIFSQ ID: ART-1193

Test your knowledge with this free 20-question Sampling quiz from Food Quality Assurance & Quality Control, part…

What this quiz covers

This Loksewa set is about sampling, the step that decides whether any laboratory result means anything, and it opens with one word: representative. A representative sample accurately reflects the characteristics of the whole lot; without that, no test result can support an accept or reject decision. The set then teaches the ICMSF sampling plan language, the four letters n, c, m and M: n is the number of sample units drawn, c is the most units allowed to exceed the m limit, m is the limit between acceptable and marginally acceptable quality, and M is the limit above which the lot is unacceptable.

The middle questions sort the plan types and the sampling methods. A two-class plan has only acceptable and unacceptable outcomes, so it needs n, c and m; a three-class plan adds a marginally acceptable zone, so it needs all four. Random sampling gives every unit an equal chance, stratified sampling represents each sub-group of a non-uniform lot, and a composite sample mixes several increments into one sample for analysis. The practical questions follow the sample from the lot to the laboratory: aseptic collection in sterile containers, cool storage and prompt analysis, increments from different locations and depths in a bulk lot, quartering to reduce the combined sample, clear labelling with identity, date, lot and sampler, and coverage of different pallets, positions and production times in storage.

n, c, m and M: four letters, one plan

The four ICMSF letters are a small code, and the questions test whether you can read it. The letter n counts the sample units. The letter c counts how many of them may cross the m line. The letter m is the lower limit, the line between acceptable and marginally acceptable. The letter M is the upper limit, the line between marginal and defective, and any unit above M fails the lot outright. Two-class plans have no marginal zone, so they have no M; three-class plans have one, so they need all four letters. The stringency rule sits above the code: the higher the health risk and the more vulnerable the intended consumer, the stricter the plan must be.

How to use this quiz

Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the numbers and definitions a food technologist is expected to know by heart.

Food Technology Loksewa – Sampling
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

A short note: sampling plans for food lots

Sampling decides whether a lot is accepted or rejected. Random sampling gives every unit an equal chance of being selected. Stratified sampling suits lots with distinct sub-groups, with each group represented. A composite sample combines several increments into one sample for analysis. For a bulk lot, take increments from different locations and depths. Increments are combined and reduced by mixing and quartering. Packaged food sampling should cover different pallets and production times. Increasing n increases confidence in the accept or reject decision. A plan's stringency should match the health risk and the intended use of the food. Label every sample container with identity, date, lot and sampler.

ICMSF sampling plans use n, c, m and M. In ICMSF plans, n is the count of sample units drawn. The letter c is the maximum number allowed to exceed the m limit. The letter m is the limit separating acceptable from marginally acceptable quality. In a three-class plan, M marks the limit where the lot becomes unacceptable. A two-class plan is defined by n, c and m; a three-class plan by n, c, m and M. The Codex published its General Guidelines on Sampling as CXG 50-2004.

Microbiological samples need sterile containers and aseptic collection. After collection, keep microbiological samples cool and analyse them promptly. Reference samples are kept so results can be verified later if disputes arise.

Remember: take increments from many places in the lot.

Questions and answers

Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.

Question 1: A representative sample is one that:

  • A. Looks the nicest
  • B. Accurately reflects the characteristics of the whole lot
  • C. Is taken only from the top of the container
  • D. Is the largest portion available

Correct answer: Accurately reflects the characteristics of the whole lot

A representative sample accurately reflects the characteristics of the whole lot : without representativeness, test results cannot be trusted for accept/reject decisions on the lot (ISO 7002 principles of sampling).

Question 2: In ICMSF sampling plans, "n" denotes:

  • A. The test method
  • B. The maximum defect level
  • C. The lot size
  • D. The number of sample units drawn from the lot

Correct answer: The number of sample units drawn from the lot

In ICMSF sampling plans, n is the number of sample units drawn from the lot (ICMSF, Microorganisms in Foods 2: Sampling for Microbiological Analysis).

Question 3: In ICMSF sampling plans, "c" denotes:

  • A. The container size
  • B. The calibration factor
  • C. The maximum allowable number of sample units exceeding the m limit
  • D. The number of pathogens

Correct answer: The maximum allowable number of sample units exceeding the m limit

In ICMSF sampling plans, c is the maximum allowable number of sample units that may exceed the m limit while the lot is still accepted (ICMSF Microorganisms in Foods 2).

Question 4: In ICMSF sampling plans, "m" denotes:

  • A. The maximum limit
  • B. The moisture content
  • C. The microbiological limit separating acceptable from marginally acceptable quality
  • D. The minimum sample weight

Correct answer: The microbiological limit separating acceptable from marginally acceptable quality

In ICMSF three-class plans, m is the microbiological limit that separates acceptable quality from marginally acceptable quality (ICMSF Microorganisms in Foods 2).

Question 5: In a three-class ICMSF plan, "M" denotes:

  • A. The limit above which the lot is unacceptable, separating marginal from defective
  • B. The minimum value
  • C. The average value
  • D. The median value

Correct answer: The limit above which the lot is unacceptable, separating marginal from defective

M is the limit above which the lot is unacceptable : it separates marginally acceptable results from defective ones (ICMSF Microorganisms in Foods 2).

Question 6: A two-class attributes sampling plan is defined by:

  • A. Only the lot size
  • B. n, c and m
  • C. The test method alone
  • D. n, c, m and M

Correct answer: n, c and m

A two-class attributes plan has only acceptable/unacceptable outcomes, so it is defined by n (sample units), c (allowed exceedances) and m (the single limit) : no M is needed (ICMSF Microorganisms in Foods 2).

Question 7: A three-class attributes sampling plan is defined by:

  • A. n and c only
  • B. pH and temperature
  • C. The lot size only
  • D. n, c, m and M

Correct answer: n, c, m and M

A three-class plan adds a marginally acceptable zone, so it needs the full set: n, c, m and the upper limit M (ICMSF Microorganisms in Foods 2).

Question 8: Random sampling means:

  • A. Taking only the first units produced
  • B. Sampling only when problems occur
  • C. Taking the easiest units to reach
  • D. Every unit in the lot has an equal chance of being selected

Correct answer: Every unit in the lot has an equal chance of being selected

In random sampling, every unit in the lot has an equal chance of being selected, which removes sampler bias : the basis for valid statistical inference (Codex CXG 50-2004, General Guidelines on Sampling).

Question 9: Stratified sampling is useful when:

  • A. The lot consists of distinct sub-groups that should each be represented
  • B. The lot is perfectly uniform
  • C. Only one sample is needed
  • D. Sampling is impossible

Correct answer: The lot consists of distinct sub-groups that should each be represented

Stratified sampling divides the lot into distinct sub-groups (strata) and samples each one, so every sub-group is represented : the right approach when the lot is not uniform (Codex CXG 50-2004).

Question 10: A composite sample is:

  • A. A single grab taken once
  • B. A duplicate of another sample
  • C. A sample taken only at the end
  • D. Several increments combined and mixed into one sample for analysis

Correct answer: Several increments combined and mixed into one sample for analysis

A composite sample combines and mixes several increments into one sample for analysis, averaging out local variation across the lot (ISO 7002; Codex CXG 50-2004).

Question 11: Increasing the sample size (n) in a sampling plan generally:

  • A. Increases confidence in the accept/reject decision
  • B. Increases the lot size
  • C. Has no effect
  • D. Decreases confidence

Correct answer: Increases confidence in the accept/reject decision

Increasing n tightens the operating characteristic curve of the plan, so the accept/reject decision becomes more discriminating and confidence in the outcome rises (sampling statistics; Codex CXG 50-2004).

Question 12: Samples for microbiological testing must be collected:

  • A. In dirty containers
  • B. Aseptically, in sterile containers, to avoid contamination
  • C. With bare hands
  • D. After long delays at room temperature

Correct answer: Aseptically, in sterile containers, to avoid contamination

Microbiological samples must be collected aseptically in sterile containers : contamination from hands, air or dirty tools would inflate counts and invalidate the result (ICMSF sampling guidance).

Question 13: After collection, microbiological samples should be:

  • A. Kept cool and analysed promptly to prevent changes in microbial numbers
  • B. Stored for weeks before analysis
  • C. Frozen and thawed repeatedly
  • D. Left in the sun

Correct answer: Kept cool and analysed promptly to prevent changes in microbial numbers

Microbiological samples must be kept cool and analysed promptly, because microbes multiply or die off during warm delays, changing the numbers the laboratory measures (ICMSF).

Question 14: The Codex General Guidelines on Sampling are published as:

  • A. CXS 193-1995
  • B. CXG 50-2004
  • C. CXG 62-2007
  • D. CXC 1-1969

Correct answer: CXG 50-2004

The Codex General Guidelines on Sampling are published as CXG 50-2004 (Codex Alimentarius). CXC 1-1969 is the General Principles of Food Hygiene, and CXS 193-1995 covers contaminants : different documents.

Question 15: When sampling a bulk lot (e.g. grain in a silo), the correct approach is to:

  • A. Sample only the centre
  • B. Take increments from different locations and depths to represent the whole
  • C. Take one handful
  • D. Sample only the surface

Correct answer: Take increments from different locations and depths to represent the whole

A bulk lot such as grain in a silo is heterogeneous, so increments must be taken from different locations and depths to represent the whole (ISO 7002; Codex CXG 50-2004).

Question 16: Sample increments are combined and then reduced to laboratory sample size by:

  • A. Mixing thoroughly and subdividing (e.g. quartering)
  • B. Heating the sample
  • C. Discarding randomly
  • D. Taking only the finest particles

Correct answer: Mixing thoroughly and subdividing (e.g. quartering)

The combined increments are mixed thoroughly and subdivided : classically by quartering : to reduce them to laboratory sample size while keeping the sub-sample representative (ISO 7002).

Question 17: Every sample container must be:

  • A. Marked with a code only the sampler knows
  • B. Left unlabelled
  • C. Clearly labelled with identity, date, lot and sampler details
  • D. Labelled only with the date

Correct answer: Clearly labelled with identity, date, lot and sampler details

Every sample container must be clearly labelled with the sample identity, date, lot and sampler details : an unlabelled sample is untraceable and useless for decisions (ISO 7002).

Question 18: A sampling plan's stringency (strictness) should be related to:

  • A. The price of the product
  • B. The size of the factory
  • C. The day of the week
  • D. The health risk posed by the hazard and the intended use of the food

Correct answer: The health risk posed by the hazard and the intended use of the food

A sampling plan's stringency must reflect the health risk posed by the hazard and the intended use of the food : high-risk hazards, such as pathogens in ready-to-eat foods, demand the strictest plans (ICMSF; Codex CXG 50-2004).

Question 19: Reference (retained) samples from each lot are kept so that:

  • A. Testing can be avoided
  • B. The warehouse looks full
  • C. Results can be verified later if disputes or complaints arise
  • D. Samples can be sold

Correct answer: Results can be verified later if disputes or complaints arise

Retained (reference) samples from each lot are kept so that results can be re-verified later if a dispute or complaint arises : they are the physical evidence behind the lot decision (standard QC retention practice).

Question 20: Sampling of packaged foods from a lot in storage should cover:

  • A. Only the front pallet
  • B. Only one carton
  • C. Different pallets, positions and production times within the lot
  • D. Only damaged packs

Correct answer: Different pallets, positions and production times within the lot

Sampling packaged foods from a lot in storage must cover different pallets, positions and production times within the lot, because variation hides exactly where a front-pallet-only sample would miss it (ISO 7002; Codex CXG 50-2004).