Food Technology Loksewa – Heat Transfer

GIFSQ ID: ART-1237

Test your knowledge with this free 20-question Heat Transfer quiz from Food Engineering & Calculations, part of…

What this quiz covers

This Loksewa set is the physics of moving heat through a food plant: conduction through walls, convection from surfaces, radiation from hot faces, and the exchangers that put them together. It opens with Fourier’s law for a slab and Newton’s law of cooling for a surface, then builds the overall heat transfer coefficient U from resistances in series: film, wall and fouling, each one adding its share. The exchanger questions then ask for heat flux, for the log mean temperature difference, and for the area or the temperature difference that a stated duty needs.

The middle of the set works the details that trip people up: what happens when the area doubles, when the wall thickness doubles, and when fouling adds a resistance to a clean exchanger. A composite wall question asks for the temperature at the join between two slabs, which is found by taking the temperature drop across the first slab alone. The set closes with a steam chest, where condensing steam meets product across a wall, a unit conversion from kilowatts to kilojoules per hour, and a furnace wall worked end to end.

Resistances add, conductances do not

The one idea that opens up most of this set is that thermal resistances in series add up, while the overall coefficient is the reciprocal of their sum. So a fouling layer always lowers U, a thicker wall always cuts the heat flow, and doubling the area always doubles the duty at fixed U and temperature difference. Work in resistances, keep the units of U as watts per square metre kelvin, and check every answer against that picture before moving on.

How to use this quiz

Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the numbers and definitions a food technologist is expected to know by heart.

Food Technology Loksewa – Heat Transfer
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

A short note: Heat transfer, conduction, convection and radiation in food plants

Heat transfer moves heat from hot to cold by conduction, convection and radiation. Conduction moves heat through a solid by Fourier's law: rate equals conductivity times area times gap, divided by thickness. A slab of conductivity 0.6 and area 3 square metres, 0.05 metres thick with an 80 kelvin gap, passes 2880 watts. Convection moves heat from a surface to a fluid by Newton's law: rate equals the film coefficient times area times gap. A 2 square metre surface with a 250 coefficient and a 30 kelvin gap gives 15 kilowatts.

The overall coefficient U pulls wall and films together: a metal wall with film coefficients 1000 and 500 gives U of 312.5, and fouling of 0.0005 on a clean U of 1000 leaves 666.67. Heat flux is U times the mean gap: U of 400 with a 50 kelvin gap gives 20000 watts per square metre. In a heat exchanger the mean gap is the log mean temperature difference: end gaps of 60 and 30 kelvin give 43.28 kelvin. A counter-flow exchanger with U of 800 and area 2 square metres passes 64 kilowatts.

Radiation needs no medium: a surface of emissivity 0.9 at 500 kelvin, facing surroundings at 300 kelvin, loses 2.78 kilowatts net. Doubling the area at the same U and gap doubles the rate from 2000 to 4000 watts. Remember: check the units on k, h and U before trusting a heat sum.

Questions and answers

Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.

Question 1: Heat conducts through a slab (k = 0.6 W/m·K, area 3 m², thickness 0.05 m) with 80 K across it. What is the heat transfer rate?

  • A. 2880 W
  • B. 1440 W
  • C. 3600 W
  • D. 5760 W

Correct answer: 2880 W

Fourier's law: q = k·A·ΔT/Δx = 0.6 × 3 × 80/0.05 = 2880 W.

Question 2: A fluid flows over a 2 m² surface with a convective coefficient of 250 W/m²·K and a 30 K temperature difference. What is the convective heat transfer rate?

  • A. 7.5 kW
  • B. 15 kW
  • C. 20 kW
  • D. 30 kW

Correct answer: 15 kW

Newton's law of cooling: q = h·A·ΔT = 250 × 2 × 30 = 15,000 W = 15 kW.

Question 3: A metal wall (thickness 0.01 m, k = 50 W/m·K) separates two fluids with film coefficients 1000 and 500 W/m²·K. What is the overall heat transfer coefficient?

  • A. 250 W/m²·K
  • B. 368.8 W/m²·K
  • C. 312.5 W/m²·K
  • D. 500 W/m²·K

Correct answer: 312.5 W/m²·K

Resistances in series: 1/U = 1/1000 + 0.01/50 + 1/500 = 0.001 + 0.0002 + 0.002 = 0.0032, so U = 312.5 W/m²·K.

Question 4: A heat exchanger has an overall coefficient of 400 W/m²·K and operates with a mean temperature difference of 50 K. What is the heat flux?

  • A. 8000 W/m²
  • B. 28000 W/m²
  • C. 40000 W/m²
  • D. 20000 W/m²

Correct answer: 20000 W/m²

Heat flux = U × mean ΔT = 400 × 50 = 20,000 W/m².

Question 5: In a counter-flow exchanger, hot fluid cools 90→60 °C while cold fluid heats 20→50 °C. With U = 800 W/m²·K and area 2 m², what is the heat transfer rate?

  • A. 64 kW
  • B. 32 kW
  • C. 80 kW
  • D. 128 kW

Correct answer: 64 kW

End differences: hot in − cold out = 90 − 50 = 40 K; hot out − cold in = 60 − 20 = 40 K. With equal end differences the LMTD is 40 K. Q = U·A·LMTD = 800 × 2 × 40 = 64,000 W = 64 kW.

Question 6: A heat exchanger has end temperature differences of 60 K and 30 K. What is the log mean temperature difference?

  • A. 40 K
  • B. 43.28 K
  • C. 45 K
  • D. 51.07 K

Correct answer: 43.28 K

LMTD = (ΔT1 − ΔT2)/ln(ΔT1/ΔT2) = (60 − 30)/ln(60/30) = 30/0.6931 = 43.28 K.

Question 7: A black-ish surface (emissivity 0.9, area 1 m²) at 500 K radiates to surroundings at 300 K. What is the net radiative heat transfer? (σ = 5.67e-8 W/m²·K⁴)

  • A. 1.55 kW
  • B. 3.28 kW
  • C. 2.78 kW
  • D. 5.44 kW

Correct answer: 2.78 kW

Net radiation: q = ε·σ·A·(T1⁴ − T2⁴) = 0.9 × 5.67e-8 × 1 × (500⁴ − 300⁴) = 5.103e-8 × 5.44e10 = 2776 W ≈ 2.78 kW.

Question 8: A slab (k = 0.5 W/m·K, area 2 m², thickness 0.1 m) carries a 50 K temperature drop. What is the heat flow?

  • A. 250 W
  • B. 750 W
  • C. 1000 W
  • D. 500 W

Correct answer: 500 W

q = k·A·ΔT/Δx = 0.5 × 2 × 50/0.1 = 500 W.

Question 9: A clean exchanger has U = 1000 W/m²·K. After fouling adds a resistance of 0.0005 m²·K/W, what is the fouled overall coefficient?

  • A. 666.67 W/m²·K
  • B. 500 W/m²·K
  • C. 786.67 W/m²·K
  • D. 2000 W/m²·K

Correct answer: 666.67 W/m²·K

Fouling adds in series with the clean resistance: 1/U_fouled = 1/1000 + 0.0005 = 0.0015, so U_fouled = 666.67 W/m²·K.

Question 10: A composite wall of two slabs (slab 1: k = 1.0 W/m·K, 0.05 m; slab 2: k = 0.5 W/m·K, 0.10 m), area 1 m², has 100 K across it. What is the steady heat flow?

  • A. 200 W
  • B. 400 W
  • C. 500 W
  • D. 800 W

Correct answer: 400 W

Total resistance per unit area: 0.05/1.0 + 0.10/0.5 = 0.05 + 0.20 = 0.25 K·m²/W. Q = A·ΔT/R = 1 × 100/0.25 = 400 W.

Question 11: For the composite wall above (100 °C hot face, 0 °C cold face, Q = 400 W), what is the interface temperature between the slabs?

  • A. 60 °C
  • B. 90 °C
  • C. 80 °C
  • D. 95 °C

Correct answer: 80 °C

The temperature drop across slab 1 is Q × R1/A = 400 × (0.05/1.0)/1 = 20 K. Interface temperature = 100 − 20 = 80 °C.

Question 12: A 0.5 m² surface transfers 5000 W to a fluid with a 25 K temperature difference. What is the convective heat transfer coefficient?

  • A. 200 W/m²·K
  • B. 500 W/m²·K
  • C. 800 W/m²·K
  • D. 400 W/m²·K

Correct answer: 400 W/m²·K

From q = h·A·ΔT: h = q/(A·ΔT) = 5000/(0.5 × 25) = 400 W/m²·K.

Question 13: A heat exchanger transfers 2000 W. If the area is doubled while U and temperature difference stay the same, what is the new rate?

  • A. 4000 W
  • B. 2000 W
  • C. 5000 W
  • D. 8000 W

Correct answer: 4000 W

Q = U·A·ΔT, so doubling the area at fixed U and ΔT doubles the rate: 2 × 2000 = 4000 W.

Question 14: Conduction through a wall gives 800 W. If the wall thickness is doubled with the same temperatures, what is the new rate?

  • A. 200 W
  • B. 400 W
  • C. 500 W
  • D. 1600 W

Correct answer: 400 W

Conduction is inversely proportional to thickness: doubling Δx halves the rate, 800/2 = 400 W.

Question 15: Three thermal resistances in series are 0.002, 0.001 and 0.004 m²·K/W. What is the overall heat transfer coefficient?

  • A. 100 W/m²·K
  • B. 168.57 W/m²·K
  • C. 142.86 W/m²·K
  • D. 333.3 W/m²·K

Correct answer: 142.86 W/m²·K

U is the reciprocal of total series resistance: U = 1/(0.002 + 0.001 + 0.004) = 1/0.007 = 142.86 W/m²·K.

Question 16: What area is needed to transfer 50,000 W with U = 500 W/m²·K and LMTD = 25 K?

  • A. 2 m²
  • B. 5 m²
  • C. 8 m²
  • D. 4 m²

Correct answer: 4 m²

From Q = U·A·LMTD: A = Q/(U·LMTD) = 50,000/(500 × 25) = 4 m².

Question 17: A steam chest has condensing steam (h = 5000 W/m²·K) on one side and product (h = 800 W/m²·K) on the other, wall resistance negligible. What is the overall coefficient?

  • A. 689.66 W/m²·K
  • B. 589 W/m²·K
  • C. 800 W/m²·K
  • D. 5800 W/m²·K

Correct answer: 689.66 W/m²·K

1/U = 1/5000 + 1/800 = 0.0002 + 0.00125 = 0.00145 (wall resistance negligible), so U = 689.66 W/m²·K.

Question 18: What mean temperature difference drives 10,000 W through an exchanger with U = 250 W/m²·K and area 2 m²?

  • A. 10 K
  • B. 20 K
  • C. 25 K
  • D. 40 K

Correct answer: 20 K

Rearranging Q = U·A·ΔT: ΔT = Q/(U·A) = 10,000/(250 × 2) = 20 K.

Question 19: Convert a heat rate of 5 kW into kJ/h.

  • A. 15000 kJ/h
  • B. 300 kJ/h
  • C. 18000 kJ/h
  • D. 180000 kJ/h

Correct answer: 18000 kJ/h

5 kW = 5 kJ/s. Over one hour (3600 s): 5 × 3600 = 18,000 kJ/h.

Question 20: A furnace wall (k = 0.8 W/m·K, area 5 m², thickness 0.2 m) has faces at 120 °C and 30 °C. What is the steady heat loss?

  • A. 900 W
  • B. 2250 W
  • C. 3600 W
  • D. 1800 W

Correct answer: 1800 W

q = k·A·ΔT/Δx = 0.8 × 5 × (120 − 30)/0.2 = 0.8 × 5 × 90/0.2 = 1800 W.