Food Technology Loksewa – Federal – Technical Assistant
GIFSQ ID: ART-1288
Test your knowledge with this free 20-question Federal – Technical Assistant quiz from Loksewa Previous Quiz, part…
What this quiz covers
This set is a tour of the food analysis laboratory, bench by bench, written for the technical assistant who works there. It opens with the milk tests that fill a dairy laboratory day: the Gerber fat test and the amyl alcohol that gives a sharp fat column, the methylene blue reduction test where a short reduction time means a high bacterial count, the clot on boiling test, and the alcohol test, both of which expose developed acidity and protein instability. Around them sit the general bench skills: the desiccator that cools hot dried samples in a moisture free atmosphere, the hand refractometer that reads total soluble solids in degrees Brix, and the analytical balance that must be levelled, zeroed and shielded from draughts before weighing.
The rest of the set covers the chemistry the assistant must do without hesitation: phenolphthalein turning pink at about pH 8.2, a 1 N sodium hydroxide solution holding 40 g per litre, media sterilized in the autoclave at 121°C at 15 psi for 15 minutes, plate counts incubated at 37°C for 24 to 48 hours, pH meters calibrated with standard buffer solutions, concentrated acids handled in a fume hood with gloves and eye protection, distilled water used to avoid interference, the blank that corrects for reagent and indicator effects, and the starch indicator added near the endpoint, never at the start.
Every test answers one question, and only one
The trap in this set is the test that looks as if it measures everything. The Gerber test measures fat, not water or acidity. The alcohol test measures protein stability, not fat or preservatives. The methylene blue test measures bacterial load, not fat or water. Before answering, ask what the test was designed to detect, and the distractors fall away: each bench method in this quiz has a single job, a single correct sample treatment, and a single reading that counts.
How to use this quiz
Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the numbers and definitions a laboratory assistant is expected to know by heart.
Choose how you want to play
A short note: Federal technical assistant
Homogenization makes the sample uniform and representative. Before weighing, level and zero the balance and protect it from draughts. A desiccator cools hot dried samples where no moisture can reach them. A hand refractometer measures total soluble solids, degrees Brix. Organoleptic evaluation uses the senses: sight, smell, taste and touch. Distilled water avoids interference from dissolved impurities. For trace-level work, glassware gets a last rinse in distilled water.
Titration is the core skill. In acid-base titration, phenolphthalein turns pink from colourless at about pH 8.2. The endpoint is the moment the indicator's colour change holds. A blank determination corrects for reagent and indicator effects. One litre of 1 N sodium hydroxide holds 40 g of NaOH. In iodometric titration, add starch indicator near the endpoint, not at the start.
Culture media are sterilized at 121 degrees, 15 psi, for 15 minutes. For total plate count, plates are incubated at 37 degrees for 24 to 48 hours. A pH meter is calibrated with standard buffers, typically pH 4, 7 and 9. Handle concentrated acids in a fume hood with gloves and eye protection. In the Gerber fat test, amyl alcohol makes the fat column separate cleanly and sharply. In the methylene blue test, a short reduction time means high bacterial count and poor milk quality. A positive clot-on-boiling test means protein instability from developed acidity. The alcohol test picks up developed acidity and milk proteins unstable to heat.
Remember: level the balance, calibrate the meter, and add the indicator last.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: In the Gerber fat test, amyl alcohol is added to
Correct answer: Give a clear, sharp separation of the fat column
In the Gerber test, amyl alcohol is added after the sulphuric acid digests the milk proteins: it lowers the surface tension and clarifies the interface so the liberated fat rises into the butyrometer neck as a sharp, clearly readable column. It does not neutralize the acid, does not preserve the sample, and does not change the fat value : it only makes the reading clean and accurate.
Question 2: A desiccator in the laboratory is used to
Correct answer: Cool hot dried samples in a moisture-free atmosphere
A desiccator is used to cool hot, freshly dried samples in a moisture-free atmosphere: the desiccant inside keeps the air dry, so the crucible or weighing bottle does not reabsorb atmospheric moisture on its way to the balance. It is not a dryer, an acid store or a sterilizer : it simply protects an already-dried sample until it can be weighed.
Question 3: In the methylene blue reduction test, a short reduction (decolourization) time indicates
Correct answer: High bacterial count and poor milk quality
In the methylene blue reduction test, the dye is decolourized by bacterial metabolism, so a short reduction time means a high bacterial count and poor milk quality : the microbes consume the available oxygen (and reduce the dye) quickly. A long reduction time, not a short one, indicates good keeping quality. The test says nothing about fat content or added water.
Question 4: A positive clot-on-boiling (COB) test in milk indicates
Correct answer: Protein instability due to developed acidity
A positive clot-on-boiling test means the milk proteins coagulate when the milk is boiled : a sign that developed acidity from bacterial fermentation has destabilized the casein. Such milk has poor keeping quality and poor heat stability, which is exactly what this quick field test screens for. It does not indicate good quality, added sugar or high solids-not-fat.
Question 5: The alcohol test of milk detects
Correct answer: Developed acidity and heat instability of milk proteins
The alcohol test (mixing milk with 68% ethanol) detects developed acidity and heat instability: ethanol coagulates milk proteins that have been destabilized by souring, so clotting indicates the milk is unfit for processing or pasteurization. It measures protein stability, not fat percentage, preservatives or vitamins.
Question 6: A hand refractometer is used to measure
Correct answer: Total soluble solids (°Brix) in juices and syrups
A hand refractometer measures total soluble solids, expressed as degrees Brix, in juices, syrups and similar liquids : the refractive index of the solution rises with dissolved sugar content. It is an optical instrument for dissolved solids, not a fat, protein or salt meter.
Question 7: In acid, base titration, phenolphthalein changes from colourless to pink at about
Correct answer: pH 8.2
Phenolphthalein is colourless in acid and turns pink at about pH 8.2, in the weakly alkaline range : that is why it is the standard indicator for titrations that end near neutrality, such as titratable acidity of milk. It does not change at pH 3 or 5, and pH 12 is far past its transition range.
Question 8: A 1 N solution of sodium hydroxide contains per litre
Correct answer: 40 g of NaOH
A 1 N (one normal) solution of NaOH contains one gram-equivalent per litre. The equivalent weight of sodium hydroxide is its molecular weight, 40, divided by its valency of 1 : so 40 g of NaOH per litre. 4 g would be 0.1 N and 100 g would be 2.5 N.
Question 9: Culture media are sterilized in the laboratory using an autoclave at
Correct answer: 121°C at 15 psi for 15 minutes
Culture media are sterilized in an autoclave at 121°C at 15 psi for 15 minutes: the saturated steam under pressure delivers moist heat that reliably destroys even bacterial spores. This is the standard laboratory sterilization cycle : 15 psi is the legitimate operating pressure here, not a unit error. Room temperature, 37°C incubation and a 5-minute boil cannot sterilize media.
Question 10: For total plate count, inoculated agar plates are incubated at
Correct answer: 37°C for 24, 48 hours
For the total plate count, inoculated agar plates are incubated at 37°C for 24, 48 hours : the temperature and time that let the mesophilic bacteria typical of food contamination form visible colonies. 100°C or 55°C would kill or distort the count, and 4°C refrigeration would prevent growth entirely.
Question 11: A pH meter is calibrated before use with
Correct answer: Standard buffer solutions (e.g. pH 4, 7 and 9)
A pH meter must be calibrated with standard buffer solutions of known pH : typically pH 4, 7 and 9 : so the electrode's response is anchored to certified reference points. Fruit juice, tap water or distilled water alone have no certified pH value and cannot serve as calibration standards.
Question 12: Organoleptic evaluation of food refers to assessment by
Correct answer: The senses : sight, smell, taste and touch
Organoleptic evaluation is assessment by the human senses : sight, smell, taste and touch (and sometimes hearing, as in crispness). It is the formal name for sensory evaluation of food, distinct from instrumental, chemical or microscopic analysis, and it remains essential for judging acceptability and detecting off-flavours.
Question 13: Before weighing, an analytical balance should be
Correct answer: Levelled, zeroed and protected from draughts
Before weighing, an analytical balance should be levelled, zeroed and shielded from draughts: levelling and zeroing establish the true reference, and draught protection stops air currents from disturbing milligram-level readings. Sunlight, heating or washing the balance would each ruin accuracy rather than help it.
Question 14: In sample preparation, homogenization is done to
Correct answer: Make the sample uniform and representative
Homogenization in sample preparation breaks the sample down and mixes it thoroughly so that the portion taken for analysis is uniform and representative of the whole. An unmixed sample would give results that reflect only the scoop taken, not the lot. It does not change the colour, dry the sample or add preservatives.
Question 15: Concentrated acids in the laboratory must be handled
Correct answer: In a fume hood wearing gloves and eye protection
Concentrated acids must be handled in a fume hood while wearing gloves and eye protection: they give off corrosive fumes and cause severe chemical burns on skin contact. Bare hands, sink disposal and open flames are all dangerous : acids must be diluted carefully (acid into water) and neutralized before disposal.
Question 16: Distilled or deionized water is used in chemical analysis to
Correct answer: Avoid interference from dissolved impurities
Distilled or deionized water is used in chemical analysis because it is free of the dissolved minerals, gases and organic traces present in tap water that could react with reagents, shift pH, or appear as contamination in blanks and standards. It prevents interference; it does not add minerals, change reagent pH or speed reactions.
Question 17: A blank determination in titration is performed to
Correct answer: Correct for reagent and indicator effects
A blank determination : running the full titration procedure with everything except the sample : is performed to measure and subtract the background contributed by reagents, indicator and titrant itself. Correcting for this background gives the true sample value. It is not for saving chemicals, diluting the sample or calibrating the burette.
Question 18: The endpoint of an acid, base titration is
Correct answer: The point where the indicator permanently changes colour
The endpoint of an acid, base titration is the point where the indicator undergoes its permanent colour change, signalling that the reaction is stoichiometrically complete. That colour change is the analyst's signal to stop adding titrant and read the burette : it is not the start, not an empty burette, and not an arbitrary point.
Question 19: Glassware for trace-level analysis is finally rinsed with
Correct answer: Distilled water
Glassware for trace-level analysis gets a final rinse with distilled water to wash away the ions and residues left by tap water and detergents, which would otherwise contaminate parts-per-million or parts-per-billion determinations. Detergent alone, tap water or oil would each introduce the very contaminants the analysis is trying to avoid.
Question 20: Starch indicator in iodometric titration is added
Correct answer: Near the endpoint
Starch indicator in iodometric titration is added near the endpoint, not at the start: added too early, starch forms a very stable complex with iodine that releases it only slowly, giving a sluggish, inaccurate endpoint. Added when the solution is pale straw-yellow, it gives the sharp blue-to-colourless change that marks the true end.