Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

Food Technology Loksewa – Federal – Food Analyst

GIFSQ ID: ART-1289

Test your knowledge with this free 20-question Federal – Food Analyst quiz from Loksewa Previous Quiz, part…

What this quiz covers

This set is the food analyst’s instrument room, and it expects the candidate to know which machine answers which question. It opens with the big four separation and measurement techniques: HPLC, which separates by differential partitioning between stationary and mobile phases; atomic absorption spectrophotometry, the workhorse for heavy metals such as lead and cadmium; gas chromatography, best for volatile compounds and pesticide residues; and thin layer chromatography, the rapid qualitative screen. Alongside them sit the classic wet chemistry values of fats and oils: peroxide value for primary oxidation, acid value as mg of KOH per gram, Polenske value for volatile water insoluble fatty acids, saponification value against molecular weight, and the Reichert Meissl value that guards the authenticity of butter and ghee.

The second half turns to the quality system that surrounds the instruments: the Karl Fischer method for moisture, vitamin C by DCPIP titration, the Beer Lambert law, the MPN technique for coliforms, ELISA built on the antigen antibody reaction, the meaning of c in an n, c, m, M sampling plan, the limit of detection, method validation as fitness for purpose, certified reference materials, and HPLC with fluorescence detection as the preferred technique for aflatoxin in peanuts. The Kjeldahl factor question belongs here too: 6.38 for milk and dairy, against the general 6.25.

Match the method to the molecule

Every question in this set is really the same question in different clothes: what does this method actually measure. AAS measures elements, so it finds metals and never sugars. Gas chromatography needs volatile analytes, so it finds pesticide residues and never proteins. Karl Fischer reacts with water, so it finds moisture and nothing else. When two options sound plausible, check the chemistry of the method first and the answer follows: the instrument cannot report what its reaction cannot see.

How to use this quiz

Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the numbers and definitions a food analyst is expected to know by heart.

Food Technology Loksewa – Federal – Food Analyst
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

A short note: Federal food analyst

Food analysis separates compounds by HPLC, partitioning between stationary and mobile phases. Gas chromatography suits volatile compounds and pesticide residues. Atomic absorption spectrophotometry determines heavy metals such as lead and cadmium. For aflatoxin in peanuts, HPLC with fluorescence detection is preferred: aflatoxins fluoresce under UV light. Thin-layer chromatography is a rapid qualitative screening tool. ELISA is based on the antigen-antibody reaction.

Peroxide value measures hydroperoxides, the primary products of early fat oxidation. The acid value counts the mg of KOH needed to neutralize the free fatty acids in one gram of oil. The saponification value falls as fatty acid chains get longer. The Polenske value measures volatile water-insoluble acids. The Reichert-Meissl value checks butter and ghee authenticity, measuring volatile water-soluble fatty acids.

In Kjeldahl, milk and dairy products use 6.38, not the general 6.25, reflecting milk protein nitrogen content. The Karl Fischer method is the specific standard for determining moisture. Vitamin C in fruit juice is measured by titrating with 2,6-dichlorophenolindophenol dye. The Beer-Lambert law says absorbance rises in direct proportion to concentration and path length. The MPN technique enumerates coliform bacteria. In a sampling plan (n, c, m, M), c sets how many units may fall between m and M. The limit of detection is the lowest concentration distinguished from a blank. Method validation shows a method is fit for its intended purpose.

A certified reference material calibrates instruments and checks accuracy.

Remember: pick the right instrument, and prove it with a reference.

Questions and answers

Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.

Question 1: High-performance liquid chromatography (HPLC) separates compounds based on

  • A. Electrical charge alone
  • B. Differential partitioning between stationary and mobile phases
  • C. Molecular size alone
  • D. Boiling point differences

Correct answer: Differential partitioning between stationary and mobile phases

HPLC separates compounds by differential partitioning between the stationary phase (the column packing) and the mobile phase (the solvent flowing through it): each compound spends a different fraction of its time held on the column versus moving with the solvent, so components emerge at different times. It is not limited to charge (that is ion exchange), size (that is size exclusion) or boiling point (that is gas chromatography).

Question 2: Atomic absorption spectrophotometry (AAS) in food analysis is primarily used to determine

  • A. Sugars
  • B. Amino acids
  • C. Heavy metals such as lead and cadmium
  • D. Vitamins

Correct answer: Heavy metals such as lead and cadmium

Atomic absorption spectrophotometry measures the absorption of light by free atoms in a flame or furnace, and in food analysis it is the workhorse technique for determining heavy metals such as lead and cadmium at trace levels. Sugars, amino acids and vitamins are determined by other methods : AAS is an elemental technique, not an organic one.

Question 3: Gas chromatography is best suited for analyzing

  • A. Volatile compounds and pesticide residues
  • B. Water
  • C. Mineral ash
  • D. Proteins

Correct answer: Volatile compounds and pesticide residues

Gas chromatography requires the analytes to be volatile (or made volatile), so it is best suited to volatile compounds : flavour and aroma components, residual solvents : and to pesticide residues, which are routinely determined by GC. Non-volatile bulk components like water, ash and proteins cannot pass through a GC column and need other techniques.

Question 4: In the Kjeldahl method, the factor 6.38 instead of the general 6.25 is used for

  • A. Milk and dairy products
  • B. Meat
  • C. Soy products
  • D. Wheat flour

Correct answer: Milk and dairy products

The factor 6.38 is the specific nitrogen-to-protein conversion factor for milk and dairy products, reflecting the nitrogen content of milk proteins (about 15.67%). The general factor 6.25 applies to foods overall, while 5.70 is used for wheat : so dairy protein calculated with 6.25 would be systematically understated.

Question 5: Peroxide value of an edible oil measures

  • A. Free fatty acids
  • B. Primary oxidation products (hydroperoxides)
  • C. Moisture content
  • D. Colour intensity

Correct answer: Primary oxidation products (hydroperoxides)

The peroxide value measures primary oxidation products : the hydroperoxides formed in the first stage of fat oxidation. A rising peroxide value signals early rancidity, before the secondary products that cause off-flavours appear. Free fatty acids are measured by the acid value instead, and moisture and colour are separate determinations.

Question 6: Acid value of an oil is expressed as

  • A. Grams of iodine absorbed
  • B. Percentage of water in the oil
  • C. pH of the oil
  • D. mg of KOH required to neutralize the free fatty acids in 1 g of oil

Correct answer: mg of KOH required to neutralize the free fatty acids in 1 g of oil

The acid value is defined as the milligrams of potassium hydroxide required to neutralize the free fatty acids in 1 gram of oil. It therefore directly measures hydrolytic rancidity : the breakdown of triglycerides into free fatty acids. It is not a pH measurement, not an iodine absorption, and not a water percentage.

Question 7: The Polenske value of a fat measures

  • A. Volatile water-insoluble fatty acids
  • B. Moisture content
  • C. Free fatty acid content
  • D. Degree of unsaturation

Correct answer: Volatile water-insoluble fatty acids

The Polenske value measures the volatile water-insoluble fatty acids in a fat : the short-chain acids that distil over but do not dissolve in water. It is the companion to the Reichert-Meissl value (which measures the water-soluble ones) and is particularly useful for detecting coconut or palm-kernel oil adulteration. It does not measure moisture, free fatty acids or unsaturation.

Question 8: Saponification value of a fat is inversely related to

  • A. Acid value
  • B. Peroxide value
  • C. Iodine value
  • D. Average molecular weight of its fatty acids

Correct answer: Average molecular weight of its fatty acids

The saponification value is the mg of KOH needed to saponify 1 g of fat: fats made of shorter-chain fatty acids contain more molecules per gram, so they consume more KOH. Hence saponification value is inversely related to the average molecular weight of the fatty acids : high SV means short chains, low SV means long chains. It is not inversely related to acid, peroxide or iodine value.

Question 9: The Reichert-Meissl value is used to check the authenticity of

  • A. Honey
  • B. Mustard oil
  • C. Sugar
  • D. Butter and ghee

Correct answer: Butter and ghee

The Reichert-Meissl value measures the volatile water-soluble fatty acids (chiefly butyric and caproic acids) that are characteristic of milk fat, so it is the classic test for the authenticity of butter and ghee : adulteration with vegetable oils lowers it. It has no application to honey, mustard oil or sugar.

Question 10: The Karl Fischer method is a specific and sensitive method for determining

  • A. Ash
  • B. Fat
  • C. Moisture (water)
  • D. Protein

Correct answer: Moisture (water)

The Karl Fischer method is the specific, sensitive standard for determining moisture (water): iodine reacts quantitatively with water in the presence of sulphur dioxide and a base, and the endpoint reveals exactly how much water was present. It is far more selective than oven drying, and it measures water only : not ash, fat or protein.

Question 11: Vitamin C in fruit juice is commonly determined by titration with

  • A. 2,6-dichlorophenolindophenol dye
  • B. EDTA solution
  • C. Sodium hydroxide
  • D. Silver nitrate

Correct answer: 2,6-dichlorophenolindophenol dye

Vitamin C (ascorbic acid) in fruit juice is commonly determined by titration with 2,6-dichlorophenolindophenol (DCPIP) dye: the dye is blue in its oxidized form and is reduced to a colourless compound by ascorbic acid, so the titration volume gives the vitamin C content. EDTA, sodium hydroxide and silver nitrate are used for hardness, acidity and chloride determinations, not vitamin C.

Question 12: According to the Beer, Lambert law, absorbance is

  • A. Directly proportional to concentration and path length
  • B. Inversely proportional to concentration
  • C. Equal to transmittance
  • D. Independent of concentration

Correct answer: Directly proportional to concentration and path length

The Beer, Lambert law states that absorbance equals the molar absorptivity times concentration times path length (A = εcl): absorbance is directly proportional to both the concentration of the absorbing species and the length of the light path through the sample. It is never equal to transmittance (absorbance is the negative logarithm of transmittance) and it is certainly not independent of concentration.

Question 13: Thin-layer chromatography (TLC) is mainly used for

  • A. Determining moisture
  • B. Rapid qualitative screening and separation of mixture components
  • C. Precise quantification of proteins
  • D. Measuring pH

Correct answer: Rapid qualitative screening and separation of mixture components

Thin-layer chromatography is mainly a rapid qualitative tool: a drop of mixture is separated on a coated plate and the components are visualized, making it ideal for quick screening : checking identity, purity or the presence of adulterants. It is not a moisture method, not a precise protein assay, and not a pH measurement.

Question 14: The MPN (most probable number) technique is used for the enumeration of

  • A. Coliform bacteria
  • B. Vitamins
  • C. Yeasts only
  • D. Total fat

Correct answer: Coliform bacteria

The MPN (most probable number) technique estimates coliform numbers statistically from the pattern of positive and negative tubes across serial dilutions : the standard approach for coliform enumeration in water and foods. It is a bacterial enumeration method, not a vitamin, yeast-only or fat determination.

Question 15: ELISA in food testing is based on

  • A. Distillation
  • B. Antigen, antibody reaction
  • C. Membrane filtration
  • D. Flame emission

Correct answer: Antigen, antibody reaction

ELISA (enzyme-linked immunosorbent assay) is based on the specific antigen, antibody reaction: the target molecule is captured by an antibody and detected through an enzyme-linked signal. In food testing it is used for allergens, toxins and pathogens. It involves no distillation, membrane filtration or flame emission.

Question 16: In a microbiological sampling plan (n, c, m, M), the term 'c' represents

  • A. The number of sample units
  • B. The detection limit of the method
  • C. The safety limit itself
  • D. The maximum number of sample units allowed to fall between m and M

Correct answer: The maximum number of sample units allowed to fall between m and M

In the ICMSF sampling-plan notation (n, c, m, M), 'c' is the maximum number of sample units permitted to give results between m and M : the marginally acceptable range : while 'n' is the number of units examined and M is the level no unit may exceed. It is an acceptance number, not the sample count, the detection limit or the safety limit itself.

Question 17: The limit of detection (LOD) of an analytical method is the

  • A. Concentration of the calibration standard
  • B. Average of all replicate readings
  • C. Lowest concentration that can be reliably distinguished from a blank
  • D. Highest concentration the method can measure

Correct answer: Lowest concentration that can be reliably distinguished from a blank

The limit of detection (LOD) is the lowest concentration of an analyte that can be reliably distinguished from a blank : typically defined at a signal-to-noise ratio of 3:1. Below the LOD the method cannot say with confidence that the analyte is even present; it is not the calibration standard concentration, an average of replicates, or the top of the working range.

Question 18: Method validation demonstrates that an analytical method is

  • A. Published in a journal
  • B. Old and established
  • C. Fit for its intended purpose
  • D. Inexpensive to run

Correct answer: Fit for its intended purpose

Method validation is the documented process of demonstrating that an analytical method is fit for its intended purpose : that it reliably measures what it claims to measure, in the matrices and ranges it will be used for. Publication, age or cheapness prove nothing about fitness for purpose; only validation data do.

Question 19: A certified reference material (CRM) is used to

  • A. Clean laboratory glassware
  • B. Preserve food samples
  • C. Calibrate instruments and verify the accuracy of results
  • D. Label finished products

Correct answer: Calibrate instruments and verify the accuracy of results

A certified reference material is a material of certified composition, issued with a certificate of analysis, used to calibrate instruments and to verify the accuracy of analytical results : including it in a run shows whether the method is giving true values. It is not a cleaning agent, a preservative or a labelling material.

Question 20: For aflatoxin analysis in peanuts, the preferred instrumental technique is

  • A. Refractometry
  • B. HPLC with fluorescence detection
  • C. Acid, base titrimetry
  • D. pH measurement

Correct answer: HPLC with fluorescence detection

For aflatoxin analysis in peanuts the preferred instrumental technique is HPLC with fluorescence detection: aflatoxins fluoresce naturally under UV light, so the fluorescence detector gives the high sensitivity needed to enforce the low regulatory limits (parts per billion). Refractometry, acid, base titration and pH measurement cannot detect aflatoxins at all.