What this quiz covers
Membranes and mixers are the two machines in this set, and the membrane half starts with the driving force. Ultrafiltration and reverse osmosis are driven by hydrostatic pressure pushing solvent through the membrane, electrodialysis instead moves ions under an electric field, and MWCO stands for molecular weight cut off, the solute weight at which the membrane retains about 90 percent. Reverse osmosis membranes are the tightest of the spectrum, effectively non porous, with an equivalent size near 0.0001 micrometres, which is why they reject dissolved salts.
The mixing half is a catalogue of standard geometry and standard speeds. Ultracentrifugation means tens of thousands of revolutions per minute, and 75,000 is squarely in that range, while paddle agitators run slow at 20 to 150 revolutions per minute. The standard ratios are worth learning as a set: impeller to tank diameter 1 to 3, paddle diameter about 0.8 of the tank, fermenter baffle width 1 tenth to 1 twelfth of the vessel, and liquid depth equal to tank diameter. An agitated vessel always develops radial, tangential and axial flow together, and paddles, flat blade turbines and disc mounted turbines all discharge mainly in the radial direction.
Vortices, pastes, and the heap test
A vortex is the centrifugal force flinging liquid outward and dipping the surface at the centre, and baffles plus a diffusion ring are the standard cures. Turbines cover the broadest viscosity range, thick pastes need kneaders or mixer extruders, the two arm kneader suits suspensions and pastes, and a heap test shows dry solids segregation fast, since fines stay near the top while coarse particles roll to the edge.
How to use this quiz
Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the correct choice in plain words, so a miss becomes a fact you keep. Learn the geometry ratios as a set before retaking, since the questions test the numbers, not the machine names alone.
Choose how you want to play
A short note: agitators, membranes and mixing vessel design
Agitators, membranes and mixing vessel design are the hardware of mixing and separation. Standard vessel geometry puts the impeller diameter at one third of the tank diameter, the liquid depth the same as the tank diameter, and the paddle diameter at about 0.8 of the tank diameter for close-clearance impellers.
Flow in an agitated vessel runs three ways: radial, outward from the shaft; tangential, around it; and axial, along it. Paddles, flat-blade turbines and disc-mounted flat-blade turbines all discharge mainly radially, while propellers drive axial flow. Turbines cover the broadest range of liquid viscosities, from thin liquids through to moderately viscous ones. Swirling and vortex formation are avoided by fitting baffles, which break rotational flow, and by using a diffusion ring with turbines.
Thick pastes and plastic masses need working by direct mechanical means: kneaders and mixer-extruders; the two-arm kneader suits suspensions, pastes and light plastic masses.
Hydrostatic pressure drives the membrane processes here: ultrafiltration and reverse osmosis push solvent through the membrane, working against the osmotic gradient, while electrodialysis moves ions through ion-selective membranes under an electric field. Reverse-osmosis membranes are the tightest in the spectrum, near 0.0001 to 0.01 micrometres. MWCO means molecular weight cut-off: the solute weight at which the membrane retains about 90 percent.
Size the vessel to the standard ratios first, then pick the impeller for the viscosity range.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: What drives flow in ultrafiltration and reverse osmosis?
Correct answer: Hydrostatic pressure
Ultrafiltration and reverse osmosis are pressure-driven membrane processes: an applied hydrostatic pressure forces the solvent through the membrane against the osmotic gradient.
Question 2: Electrodialysis works on the movement of
Correct answer: Ions
In electrodialysis an electric field pulls cations and anions through ion-selective membranes toward the electrodes; it is the ions that migrate, not the water.
Question 3: The general pore-size range of a reverse-osmosis membrane is
Correct answer: 0.0001, 0.01 μm
Reverse-osmosis membranes are the tightest of the membrane spectrum : effectively non-porous (solution, diffusion), with an equivalent size around 0.0001 µm : which is why RO rejects dissolved salts.
Question 4: What does MWCO stand for?
Correct answer: Molecular weight cut-off
MWCO stands for molecular weight cut-off: the solute molecular weight (in daltons) at which the membrane retains about 90% of the solute.
Question 5: Which rotor speed falls in the ultracentrifugation category?
Correct answer: 75,000 rpm
Ultracentrifuges spin at tens of thousands of rpm (up to roughly 80,000); 75,000 rpm is squarely in the ultracentrifugation range, while 5,000, 11,000 rpm is ordinary high-speed centrifugation.
Question 6: Paddle agitators are generally run at
Correct answer: 20, 150 rpm
Paddle agitators are low-speed impellers; the Food Processing Handbook gives their normal operating range as 20, 150 rpm.
Question 7: Which flow patterns occur in an agitated vessel?
Correct answer: All of these
An agitated vessel always develops all three components: radial flow (outward from the shaft), tangential/rotational flow (around the shaft) and longitudinal (axial) flow (parallel to the shaft).
Question 8: Vortexing involves which force?
Correct answer: Centrifugal force
The rotating liquid is flung outward by centrifugal force, depressing the surface at the centre : that dip is the vortex.
Question 9: What is the usual ratio of impeller diameter to tank diameter (D_a : D_t)?
Correct answer: 1 : 3
The standard geometric ratio for turbine-type impellers is Da/Dt = 1/3, i.e. the impeller diameter is one-third of the tank diameter.
Question 10: In paddle-agitator design, the paddle diameter is normally what fraction of the tank diameter?
Correct answer: 0.8
Paddle, anchor and gate impellers sweep close to the wall; their diameter is generally about 80% of the tank diameter.
Question 11: In a fermenter, the baffle width is usually what fraction of the vessel diameter?
Correct answer: 1/10 to 1/12
Fermenter baffles are sized at roughly one-tenth to one-twelfth of the vessel diameter : wide enough to break the swirl, narrow enough to avoid dead zones (the metric standard is T/10, the American T/12).
Question 12: What is the usual ratio of liquid depth to tank diameter (H : D_t) in a mixing vessel?
Correct answer: 1 : 1
Standard agitated-vessel geometry sets the liquid depth equal to the tank diameter (H = Dt).
Question 13: Which of these impellers move the liquid mainly in a radial direction?
Correct answer: All of the above
Paddles, flat-blade turbines and disc-mounted (Rushton) turbines all discharge liquid predominantly in the radial direction.
Question 14: How can swirling and vortex formation in a mixing tank be avoided?
Correct answer: Both of these
Baffles break up the rotational flow that feeds a vortex, and a diffusion ring around a turbine straightens its discharge : both are standard anti-swirl measures.
Question 15: Which impeller type handles the broadest range of liquid viscosities?
Correct answer: Turbines
Turbines operate from thin liquids up to moderately viscous ones (hundreds of poise), a wider span than propellers (low viscosity only) or paddles (mainly viscous duty).
Question 16: What equipment is commonly used for mixing thick pastes and plastic masses?
Correct answer: Both of these
Thick pastes and plastic masses need direct mechanical working rather than pumped circulation: kneaders (e.g. sigma-blade) and mixer-extruders are the standard machines (Food Processing Handbook §15.1.3).
Question 17: Which mixer is suited to suspensions, pastes, and light plastic masses?
Correct answer: Two-arm kneader
The two-arm (sigma-blade) kneader's counter-rotating blades shear and fold heavy suspensions, pastes and light plastic masses; ribbon blenders suit dry solids and static mixers suit pumpable liquids.
Question 18: Which test quickly reveals particle separation in a blended dry-solids mixture?
Correct answer: Heap test
Pouring the blend into a heap makes segregation visible: fines stay near the centre/top of the heap while coarser particles roll to the periphery (heap segregation), so comparing samples from the two zones quickly reveals separation.
Question 19: What does the effectiveness of a mixer depend on?
Correct answer: Both of these
How well a mixer performs depends on what it is mixing : the material's nature (powder, paste, liquid) and its consistency (viscosity, cohesiveness) both set the uniformity it can achieve.
Question 20: Using the variance-ratio definition of mixing index (initial variance divided by sample variance), what is its value before mixing begins?
Correct answer: 1