What this quiz covers
Heat transfer runs on a small family of dimensionless numbers, and this quiz tests whether you can name each one and say what it weighs. The Reynolds number rules forced convection, the Biot number weighs convection at the surface against conduction inside the solid, and natural convection on a vertical plate turns turbulent when Grashof times Prandtl reaches about 10 to the power 9. In forced convection the Nusselt number follows Reynolds and Prandtl together, the Dittus-Boelter correlation is the workhorse for turbulent pipe flow, and the sharp gradients live inside the thin boundary layer.
The second half sorts heat exchangers by type and by the numbers used to size them. A heat exchanger simply moves sensible or latent heat from one stream to another, a car radiator is a cross flow unit, and a double pipe unit is the cheap answer for a small duty such as cooling lubricating oil. The approach is the temperature gap between the streams at one end, the log mean is the difference of the end differences divided by the log of their ratio, and counter flow gives the larger log mean and so needs the least surface for a given duty. The fouling factor is the extra resistance that dirt layers add to heat flow, and there is no standard McAdams correction factor in exchanger analysis.
The one false claim, and the one debatable key
Heat can travel with no material medium at all: sunlight crosses near vacuum to reach Earth, so the claim that heat needs a medium is the false one. One key deserves a second look: the quiz says cooling water may go through either side of a refrigerant condenser, while standard practice puts the refrigerant on the shell side and the water through the tubes.
How to use this quiz
Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the correct choice in plain words, so a miss becomes a fact you keep. Learn the number pairs before retaking: Reynolds with forced convection, Biot with surface against solid, and Grashof times Prandtl with the 10 to the power 9 transition.
Choose how you want to play
A short note: heat exchangers, forced convection and LMTD
A heat exchanger heats or cools a product stream. The Reynolds number rules forced convection. The Biot number compares surface convection with inside conduction. Natural convection turns turbulent when the Rayleigh number reaches about 10⁹. In forced convection, Nu is a function of Re and Pr. The boundary layer is the thin region where velocity and temperature change sharply. Dittus–Boelter, Nu = 0.023 Re⁰·⁸ Prⁿ, gives the coefficient for turbulent flow in a tube.
A heat exchanger moves heat between two streams without mixing them. Heat crosses a vacuum: sunlight crosses space. In a food plant, exchangers raise or lower the product's temperature. A car radiator is a cross-flow exchanger, air blowing across the coolant tubes. For a small duty, use a double-pipe exchanger. Condensing refrigerant: cooling water can run on either side. The McAdams correction factor is not a heat-exchanger analysis term. The approach is the end temperature gap.
Parallel flow: LMTD is (Δti − Δte)/ln(Δti/Δte). Counter-flow gives a bigger LMTD than parallel-flow. In parallel flow, the hot stream cannot cool below the cold stream's outlet temperature. Counter-flow needs the smallest area for a given duty. The fouling factor adds resistance from dirt layers. A double-pipe exchanger suits a small surface area.
Pick counter-flow for the least surface, double-pipe for the smallest duty, and always allow for fouling.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: Which dimensionless number plays the key role in forced convection?
Correct answer: Reynolds number
In forced convection the flow field rules heat transfer, and the Reynolds number : inertial forces over viscous forces : is the dimensionless group that characterises that flow.
Question 2: Which dimensionless group compares convection at a surface with conduction inside the solid?
Correct answer: Biot number
The Biot number (hL/k) weighs convection at the surface against conduction inside the solid. A small Bi means the body stays nearly uniform within; a large one means internal gradients matter.
Question 3: On a vertical plate, natural-convection flow turns turbulent when the product of Grashof and Prandtl numbers reaches approximately what value?
Correct answer: 10⁹
The Rayleigh number Ra = Gr·Pr marks the laminar-to-turbulent transition on a vertical plate at about 10⁹ : below it the boundary layer stays laminar, above it turbulence takes over.
Question 4: In forced convection, the Nusselt number is a function of which numbers?
Correct answer: Reynolds and Prandtl numbers
In forced convection the Nusselt number correlates with the Reynolds number (the flow) and the Prandtl number (the fluid's thermal character) : the Dittus, Boelter form Nu = 0.023 Re⁰·⁸ Prⁿ is the classic example.
Question 5: In convection, temperature and velocity gradients change sharply only within which region?
Correct answer: Boundary layer
Outside the thin boundary layer the fluid sits essentially at free-stream conditions; all the sharp velocity and temperature gradients are packed inside that layer.
Question 6: The correlation most widely used for the heat-transfer coefficient in turbulent pipe flow is known as which equation?
Correct answer: Dittus, Boelter equation
The Dittus, Boelter correlation (Nu = 0.023 Re⁰·⁸ Prⁿ) is the workhorse for the coefficient in turbulent pipe flow. Hagen, Poiseuille describes laminar pressure drop and Fourier describes conduction : different jobs.
Question 7: What is the name of equipment that transfers sensible or latent heat from one fluid stream to another?
Correct answer: a heat exchanger
A heat exchanger is defined by its job: moving sensible or latent heat from one stream to another. Boilers, extractors, and distillation columns each do something more specific on top of that.
Question 8: Which of these claims about heat transfer is false?
Correct answer: Heat can travel only through some material medium
Sunlight crosses 150 million kilometres of near-vacuum to reach Earth, so heat plainly does not need a material medium : radiation falsifies that claim outright.
Question 9: In a food plant, heat exchangers are installed mainly to do what?
Correct answer: raise or lower the temperature of the product
Pasteurisers, sterilisers, coolers, and heaters are all heat exchangers doing one fundamental job: shifting the product's temperature to its target, up or down.
Question 10: A car radiator belongs to which heat-exchanger family?
Correct answer: cross-flow type
A car radiator blows air across finned tubes carrying hot coolant : the two streams cross at right angles, which is the textbook definition of cross-flow.
Question 11: Which heat exchanger suits a small duty such as cooling lubricating oil?
Correct answer: double-pipe unit
Double-pipe units are the simple, cheap answer for small duties like lube-oil cooling; shell-and-tube construction only earns its complexity once the duty grows large.
Question 12: A shell-and-tube unit is condensing refrigerant vapour while cooling water removes the heat. The water may be sent through
Correct answer: either the shell side or the tube side
Standard practice puts the condensing refrigerant on the shell side and the cooling water through the tubes : water-side cleaning and simpler manifolding are the reasons (ScienceDirect condenser review). Special tube-side condensers with water on the shell do exist, which is the only reading under which ‘either side’ holds.
Question 13: Which term does NOT belong to heat-exchanger analysis?
Correct answer: McAdams correction factor
Fouling factor, NTU, and capacity ratio are all working terms of exchanger analysis. There is no standard ‘McAdams correction factor’ : McAdams is known for a convection correlation, not a correction factor.
Question 14: The temperature gap between the hot and cold streams measured at either end of a heat exchanger is called the
Correct answer: approach
The ‘approach’ is the temperature gap between the hot and cold streams measured at one end of the unit : hot-in minus cold-out, or hot-out minus cold-in.
Question 15: For a parallel-flow exchanger, if Δti is the temperature difference at the inlet end and Δte at the exit end, the log mean temperature difference equals
Correct answer: (Δti − Δte)/ln(Δti/Δte)
The log mean is the difference of the two end temperature differences divided by the logarithm of their ratio: (Δti−Δte)/ln(Δti/Δte).
Question 16: How does the LMTD of a counter-flow exchanger compare with that of a parallel-flow unit on the same duty?
Correct answer: it is larger
For the same four terminal temperatures, counterflow keeps the two streams further apart along the whole length, so its log mean difference : the driving force : is the larger of the two.
Question 17: In a parallel-flow exchanger, the coldest the hot stream can theoretically get is ___ the outlet temperature of the cold stream.
Correct answer: the same as
In parallel flow the hot stream can never cross the cold stream's temperature; the cold outlet is the floor the hot stream approaches asymptotically but cannot pass.
Question 18: For a fixed duty and fixed inlet and outlet temperatures, which arrangement needs the least surface area?
Correct answer: counter-flow
Required area is Q/(U·LMTD). Counterflow gives the largest LMTD for given inlet and outlet temperatures, so it needs the least surface for the duty.
Question 19: What does the fouling factor represent?
Correct answer: the extra resistance that dirt layers add to heat flow
The fouling factor is a thermal resistance (m²K/W) added in series with the clean resistances : it represents the scale, biofilm, or deposit layer throttling heat flow.
Question 20: Double-pipe exchangers are the right choice when
Correct answer: only a small surface area is needed
Double-pipe exchangers stay economical only while the required area is small; once the duty grows, the pipe runs become absurdly long and shell-and-tube construction wins.