Food Engineering Part 19 Quiz

GIFSQ ID: ART-1096

Test your knowledge with this free 20-question Food Engineering quiz (Part 19). Choose the correct answer for each…

What this quiz covers

This set stays inside the shell and tube exchanger, the workhorse of food plant heating and cooling, and it starts with the one case where flow arrangement stops mattering. When one stream boils or condenses it holds a single temperature along the whole unit, so the log mean temperature difference comes out the same for parallel, counter and cross flow, and the surface area needed is the same too. The annulus gets two equivalent diameters: (d2 squared minus d1 squared) over d1 for heat transfer work, and simply d2 minus d1 for pressure drop work, because that calculation counts both wetted walls. A worked example warms water from 20 to 80 degrees C against gas cooling from 140 to 80, and since both end differences are 60 degrees C the log mean is 60 degrees C.

The design choices follow from the same logic. Finned tubes suit air heating because air has a poor film coefficient and fins answer with extra surface, and several tube passes raise the overall coefficient by pushing up tube side velocity, at the price of extra pressure drop. Orifice baffles cost the most shell side pressure drop, triangular pitch wins for clean fluids, and the tube side coefficient is theoretically infinite right at the entrance, where the boundary layer has zero thickness. Saturated steam gives the highest coefficient, corrosive liquid goes through the tubes where alloy is cheapest, and a 1-1 exchanger gives the lowest tube side pressure drop.

Plates, pasteurisers, and the milk that boils over

Plate exchangers use pressed stainless steel plates about 3 mm apart, a pasteuriser and a steriliser differ only in the temperature reached, and regeneration only pays when the same stream is first heated and later cooled, so the hot outgoing stream can warm the cold incoming one. The set closes in the kitchen: milk boiling over in an open vessel is saturated nucleate boiling, bulk liquid at saturation erupting in vapour bubbles.

How to use this quiz

Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the correct choice in plain words, so a miss becomes a fact you keep. Keep the two annulus diameters apart before retaking: the heat transfer one divides by d1, the pressure drop one is just d2 minus d1.

Food Engineering Part 19 Quiz
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

A short note: shell-and-tube exchangers, finned tubes and regeneration

A shell-and-tube exchanger handles very large duties. With one stream boiling or condensing, the area needed is the same for every arrangement. For heat transfer the annulus diameter is (d2² − d1²)/d1, and d2 − d1 for pressure drop. Counter-flow, water 20 to 80 °C, gas 140 to 80 °C: LMTD is 60 °C. Finned tubes give air much more surface for heat transfer. Tube vibration can be set off by flow, surging, or vibration from piping.

Orifice baffles give the largest shell-side pressure drop. At the tube entrance, the local coefficient is theoretically infinite. Triangular pitch performs best with clean, non-fouling fluids. Shell-side velocity changes with tube layout and pitch together. Shell-and-tube units take on the heaviest duties well. Several tube passes raise the overall heat-transfer coefficient. Saturated steam gives the highest heat-transfer coefficient. A 1-1 exchanger keeps tube-side pressure drop low. Route a corrosive liquid through the tubes.

Plate exchangers use stainless-steel plates. The plate gap is about 3 mm. A pasteurizer and a sterilizer differ only in temperature reached. Regeneration pays when a stream is first heated and later cooled. Milk boiling over in an open vessel is saturated nucleate boiling.

Put the weak fluid outside, the corrosive fluid inside, and the fins where the air is.

Questions and answers

Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.

Question 1: When one stream is boiling or condensing, the surface area needed is

  • A. smallest with parallel flow
  • B. smallest with counter flow
  • C. smallest with cross flow
  • D. the same for every flow arrangement

Correct answer: the same for every flow arrangement

When one stream changes phase it stays at a single temperature along the whole unit, so the log mean temperature difference works out identically for parallel, counter, and cross flow. Equal LMTD means equal required area, whatever the arrangement.

Question 2: For heat-transfer work, the annulus equivalent diameter : with d1 the inner pipe's outside diameter and d2 the outer pipe's inside diameter : comes out as

  • A. (d2² − d1²)/d1
  • B. (d2² + d1²)/d1
  • C. (d2² − d1²)/4d1
  • D. (d2² − d1²)/d1d2

Correct answer: (d2² − d1²)/d1

For heat transfer, Kern's equivalent diameter is 4 × flow area ÷ heated perimeter. The annulus area is (π/4)(d2²−d1²) and the heated perimeter is the inner pipe's πd1, which simplifies to (d2²−d1²)/d1.

Question 3: For pressure-drop work, using the same two diameters, the annulus equivalent diameter is

  • A. (d2² + d1²)/d1
  • B. (d2² − d1²)/4d1
  • C. d2 − d1
  • D. (d1 + d2)/4

Correct answer: d2 − d1

For pressure drop the fluid wets both walls, so the hydraulic diameter is 4 × area ÷ total wetted perimeter = (d2²−d1²)/(d2+d1), which factors neatly to d2−d1.

Question 4: A counter-flow exchanger warms water from 20 °C to 80 °C with hot exhaust gas that enters at 140 °C and leaves at 80 °C. The log mean temperature difference is

  • A. 80 °C
  • B. 60 °C
  • C. 110 °C
  • D. cannot be found from this data

Correct answer: 60 °C

Counterflow end differences: hot end 140−80 = 60 °C, cold end 80−20 = 60 °C. With the two end differences equal, the log mean is simply 60 °C.

Question 5: Finned tubes are preferred for heating air because they provide

  • A. higher metal conductivity
  • B. stronger natural convection
  • C. a smaller pressure drop
  • D. much more surface for heat transfer

Correct answer: much more surface for heat transfer

Air's film coefficient is poor, and fins answer a weak coefficient with extra surface rather than trying to improve the coefficient itself : that trade is the whole economic case for finned tubes in air service.

Question 6: Tube vibration in a shell-and-tube exchanger can be set off by

  • A. flow on the shell and tube sides
  • B. surging of the shell-side or tube-side flow
  • C. outside forces carried in through pipes or supports
  • D. all of these causes

Correct answer: all of these causes

Shell-side or tube-side flow, surging on either side, and vibration carried in through piping or supports can each excite a tube bundle, so every one of these sources belongs in the answer.

Question 7: Shell-side pressure drop is largest with which baffle style?

  • A. orifice baffles
  • B. disc-and-ring baffles
  • C. segmental baffles
  • D. none of these

Correct answer: orifice baffles

Orifice baffles force the shell fluid through tight annular gaps around each tube : the most constricted path of the three styles : and that throttling costs the most pressure drop.

Question 8: Right at the tube entrance, the local tube-side heat-transfer coefficient is theoretically

  • A. infinitely large
  • B. zero
  • C. equal to the tube-side average
  • D. none of these

Correct answer: infinitely large

At the exact tube inlet the thermal boundary layer has zero thickness, so the wall temperature gradient : and with it the local coefficient : is theoretically unbounded, relaxing downstream as the layer thickens.

Question 9: With clean, non-fouling fluids, which tube layout performs best?

  • A. square pitch
  • B. triangular pitch
  • C. rotated square pitch
  • D. none of these

Correct answer: triangular pitch

Triangular layout packs more tubes into a shell and stirs the shell fluid more aggressively, giving roughly 10, 20% better heat transfer than square pitch. Its drawback (no cleaning lanes) only bites with fouling fluids, so clean service favours triangular.

Question 10: The velocity of the shell-side fluid can be altered by changing the tube

  • A. layout
  • B. pitch
  • C. layout and pitch together
  • D. neither of these

Correct answer: layout and pitch together

Shell-side velocity is the mass flow divided by the cross-flow area at the shell centreline, and that area is set by both the tube pitch and the geometric layout of the tubes together.

Question 11: Shell-and-tube units handle very large duties well because they

  • A. are simple to run and service
  • B. cost less than other types
  • C. take up little floor space
  • D. offer all of these advantages

Correct answer: offer all of these advantages

Shell-and-tube units rule heavy-duty service because they are simple to run and service, cheaper per unit of area than the alternatives, and pack a lot of surface into a modest footprint : all three advantages at once.

Question 12: For the same duty and the same tube-side flow, using several tube passes helps because it

  • A. cuts the pressure drop
  • B. lowers the coolant outlet temperature
  • C. raises the overall heat-transfer coefficient
  • D. none of these

Correct answer: raises the overall heat-transfer coefficient

Splitting the same total tube-side flow into more passes leaves fewer tubes per pass, so the velocity in each tube rises. Higher velocity lifts the tube-side film coefficient and with it the overall U (paid for with extra pressure drop).

Question 13: Steam gives its highest heat-transfer coefficient when it is

  • A. superheated
  • B. saturated
  • C. wet
  • D. none of these

Correct answer: saturated

Saturated steam condenses at constant temperature with a film coefficient in the thousands. Superheated steam must first cool as a mere gas, and wet steam carries an insulating liquid film : both give lower coefficients.

Question 14: To keep the tube-side pressure drop low at a given flow rate, which unit is recommended?

  • A. a 1-2 exchanger
  • B. a 1-1 exchanger
  • C. a 3-2 exchanger
  • D. a 2-4 exchanger

Correct answer: a 1-1 exchanger

Each added tube pass raises velocity, and pressure drop climbs roughly with velocity squared. A single tube pass (1-1) keeps the flow path shortest and slowest, hence the lowest tube-side drop at a given flow rate.

Question 15: In a shell-and-tube exchanger a corrosive liquid is normally routed through the

  • A. tubes
  • B. shell
  • C. either side
  • D. neither side

Correct answer: tubes

Corrosion-resistant alloy is expensive, and tubing needs far less of it than a whole shell would; tubes are also easier to inspect, clean, and replace than the shell.

Question 16: Plate heat exchangers normally use plates pressed from

  • A. stainless steel
  • B. plain iron
  • C. aluminium
  • D. a copper alloy

Correct answer: stainless steel

Plates must be thin, formable, strong, and corrosion-proof across food and chemical duties. Stainless steel is the standard pressable material : plain iron would corrode, aluminium is too weak for the pressing and pressure, and copper alloys cost too much.

Question 17: The gap between plates in a plate heat exchanger is about

  • A. 1 mm
  • B. 3 mm
  • C. 5 mm
  • D. 7.5 mm

Correct answer: 3 mm

Pressed-plate channels run about 1.5, 5 mm apart (Kakac's nominal range), giving hydraulic diameters of 4, 10 mm : narrow enough for high shear and turbulence at low flow rates. 3 mm sits squarely in that standard range.

Question 18: A pasteurizer and a sterilizer differ from each other only in

  • A. the heating medium used
  • B. the temperature reached
  • C. the way the vessel is built
  • D. none of these

Correct answer: the temperature reached

Pasteurization and sterilization are the same kind of heat treatment; the line between them is drawn at the temperature (with its holding time) the product reaches : sterilisers run near 121 °C, pasteurisers far lower.

Question 19: Regeneration makes economic sense for a product stream that is

  • A. only heated
  • B. only cooled
  • C. first heated and later cooled
  • D. neither heated nor cooled

Correct answer: first heated and later cooled

Regeneration recovers heat from the hot outgoing stream into the cold incoming one. That trade only pays when the same product must first be heated and later cooled, so the two duties can feed each other.

Question 20: When milk boiled in an open vessel foams up and runs over the rim, the boiling regime is

  • A. film boiling
  • B. saturated nucleate boiling
  • C. subcooled boiling
  • D. none of these

Correct answer: saturated nucleate boiling

Milk boiling over is bulk liquid at its saturation temperature erupting in vapour bubbles : textbook saturated nucleate boiling, not the subcooled regime (bulk still below saturation) or film boiling (a vapour blanket at extreme ΔT).