What this quiz covers

Food engineering starts with cold and steam, and this quiz tests both. The first half is refrigeration: the vapour compression cycle, what a good refrigerant looks like, and the numbers that define the plant. A throttling device meters liquid refrigerant into the evaporator, and the net refrigeration effect is the heat each kilogram of refrigerant picks up per cycle.

Twenty questions move from cold to steam to the maths. The third law of thermodynamics deals with entropy, and a boiler turns the chemical energy of fuel into heat. Float valves sit at the evaporator inlet on the low side and at the condenser outlet on the high side. One boiler horsepower evaporates 34.5 lb of water per hour into dry saturated steam at 212 °F, and a low-pressure boiler stays below 15 psig. Then the calculations: a venturi meter reads flow rate, a superheater lifts steam above its saturation temperature, and the set closes with worked numbers: steam enthalpy by interpolation, heat transfer from a tube, a z-value of 111 K, a 3:2 Pearson square blend, and a specific heat near 0.8 BTU per lb per °F.

Concepts you will need

Two ideas carry this set. First, the refrigeration cycle is a loop of four steps, and each device has one place: the throttling device feeds the evaporator, the compressor lifts the vapour, the condenser rejects the heat. Second, the boiler definitions are fixed numbers to learn as pairs: 34.5 lb per hour with one boiler horsepower, 15 psig with low pressure, 212 °F with the steam basis.

How to use this quiz

You get 20 seconds per question and one attempt at each answer, so learn the cycle order first: evaporator, compressor, condenser, throttling device, and back again. Then fix the three boiler numbers: 34.5, 15, and 212. When a question gives you numbers and asks for an estimate, work the arithmetic step by step instead of guessing from the options: the interpolation and the Pearson square both reward a slow hand. Then retake the quiz and check the numbers hold.

Food Engineering Part 1 Quiz
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

A short note: vapour compression refrigeration and plant calculations

A vapour compression system moves refrigerant around evaporator, compressor, condenser and throttling device. The throttling device sets flow into the evaporator, and net refrigeration effect is the heat taken in per unit mass each cycle. A good refrigerant needs very large latent heat, and higher COP means lower running cost. Float valves sit at the evaporator inlet on the low side and the condenser outlet on the high side.

In a boiler, chemical energy turns into heat. One boiler horsepower evaporates 34.5 lb of water hourly into dry saturated steam at 212 degrees F, and a low pressure boiler makes steam below 15 psig. A superheater lifts steam above saturation, locomotive boilers are fire-tube types, and in a Lancashire boiler water surrounds the gas tubes. A positive displacement pump pushes on a confined volume of liquid, and a venturi meter measures pipe flow.

Interpolation estimates a value between known points: steam enthalpy at 53 degrees C is 2597.4 kJ per kg from the 50 and 55 degree values. Air at 50 degrees C over a steam tube gives about 23 W per metre. Blending is mass balance: 65 percent concentrate and 15 percent juice blend 3 to 2 for a 45 percent product. Specific heat follows composition: 10 percent protein, 20 percent fat and 70 percent water gives about 0.8 BTU/(lb·°F). Vitamin C loss gives a z-value of 111 K from an activation energy of 5 kcal per mol.

Work the numbers before trusting a plant reading.

Questions and answers

Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.

Question 1: The function of a throttling device in a vapour compression system is

  • A. to release vapour when its pressure exceeds the safety limit
  • B. to evaporate the liquid refrigerant
  • C. to control the amount of refrigerant flowing into the evaporator
  • D. to reduce the pressure of refrigerant vapour and send it to the compressor

Correct answer: to control the amount of refrigerant flowing into the evaporator

The throttling device : an expansion valve or capillary tube : meters liquid refrigerant into the evaporator at a rate matching the cooling load while dropping its pressure so it can evaporate at low temperature. Releasing overpressure vapor is the job of a separate safety relief device.

Question 2: What is meant by the net refrigeration effect?

  • A. The heat absorbed by the refrigerant per unit mass during each cycle
  • B. The mass of ice that one ton of refrigerant can produce in one hour
  • C. The heat taken up by one ton of refrigerant from one ton of water in one hour
  • D. The heat needed to melt one ton of ice at 32°F

Correct answer: The heat absorbed by the refrigerant per unit mass during each cycle

The net refrigeration effect is the heat absorbed by the refrigerant per unit mass during each cycle : the enthalpy gain across the evaporator. Definitions involving tons of ice melted describe capacity units, not the effect itself.

Question 3: What should the enthalpy of vaporization (latent heat) of a good refrigerant be?

  • A. Very large, though not infinite
  • B. Infinite
  • C. Very small
  • D. It makes no difference

Correct answer: Very large, though not infinite

A good refrigerant needs a very large latent heat of vaporization, since more cooling is delivered per kilogram circulated. An infinite value is physically impossible, and a very small latent heat would demand impractically large mass flow rates.

Question 4: Which of the following statements about refrigerants is correct?

  • A. A refrigerant should have minimum thermal conductivity
  • B. A refrigerant should have a high freezing point
  • C. The higher the coefficient of performance, the higher the running cost
  • D. The higher the coefficient of performance, the lower the running cost

Correct answer: The higher the coefficient of performance, the lower the running cost

The coefficient of performance is cooling delivered per unit of work input, so a higher COP means less electricity for the same cooling : running cost falls as COP rises.

Question 5: What does the third law of thermodynamics deal with?

  • A. Enthalpy
  • B. Temperature
  • C. Entropy
  • D. Freezing point

Correct answer: Entropy

The third law of thermodynamics deals with entropy: the entropy of a perfect crystal approaches zero as the temperature approaches absolute zero.

Question 6: In a boiler, which energy conversion takes place?

  • A. Chemical energy is converted into heat energy
  • B. Chemical energy is converted into potential energy
  • C. Mechanical energy is converted into heat energy
  • D. Heat energy is converted into nuclear energy

Correct answer: Chemical energy is converted into heat energy

In a boiler, fuel is burned and its chemical energy is converted into heat energy, which raises steam. No conversion to potential, mechanical, or nuclear energy occurs in a conventional boiler.

Question 7: Where is the low-side float valve placed in a vapour compression refrigeration system?

  • A. At the inlet of the evaporator
  • B. Before the condenser
  • C. At the inlet of the compressor
  • D. At the outlet of the condenser

Correct answer: At the inlet of the evaporator

The low-side float valve is placed at the inlet of the evaporator, where it maintains a constant liquid level by admitting refrigerant as fast as it boils off.

Question 8: Where is the high-side float valve placed in a vapour compression refrigeration system?

  • A. At the inlet of the evaporator
  • B. Before the condenser
  • C. At the inlet of the compressor
  • D. At the outlet of the condenser

Correct answer: At the outlet of the condenser

The high-side float valve is placed at the outlet of the condenser, draining condensed liquid to the evaporator as fast as it forms so the condenser stays free of liquid flooding.

Question 9: How is one boiler horsepower defined?

  • A. Evaporation of 34.5 lb of water per hour into dry saturated steam at 212°F
  • B. Evaporation of 34.5 lb of water per second into dry saturated steam at 212°F
  • C. Evaporation of 50.6 lb of water per second into dry saturated steam at 212°F
  • D. Evaporation of 34.5 lb of water per hour into dry saturated steam at 100°F

Correct answer: Evaporation of 34.5 lb of water per hour into dry saturated steam at 212°F

One boiler horsepower is defined as the evaporation of 34.5 lb of water per hour into dry saturated steam at 212 °F : the classic 'from and at 212 °F' basis, equivalent to about 33,475 BTU/h.

Question 10: Up to what pressure does a low-pressure boiler generate steam?

  • A. Less than 15 psig
  • B. Less than 5 psig
  • C. Less than 20 psig
  • D. Less than 10 psig

Correct answer: Less than 15 psig

A low-pressure boiler generates steam at less than 15 psig, the ASME Section IV heating-boiler limit. Steam at higher pressures falls under power-boiler rules.

Question 11: Locomotive boilers are examples of which type of boiler?

  • A. Fire-tube boilers
  • B. Water-tube boilers
  • C. Vertical boilers
  • D. All of the above

Correct answer: Fire-tube boilers

Locomotive boilers are horizontal multitubular fire-tube boilers: hot gases pass through tubes surrounded by water, a compact arrangement suited to the locomotive frame.

Question 12: In a Lancashire boiler, how are the water and the hot gases arranged?

  • A. Steam flows through the tubes with hot air around them
  • B. Water flows through the tubes with hot air around them, as in a water-tube boiler
  • C. Water stays inside the tubes while steam collects outside them
  • D. Water surrounds the tubes that carry the hot gases

Correct answer: Water surrounds the tubes that carry the hot gases

The Lancashire boiler is a fire-tube boiler: two large furnace tubes carry the hot gases, and water surrounds the tubes in the shell, generating steam in the water space around them.

Question 13: What does a superheater do in a boiler?

  • A. It heats the steam above its melting point
  • B. It raises the steam pressure above the saturation pressure
  • C. It raises the steam temperature above the saturation temperature
  • D. All of the above

Correct answer: It raises the steam temperature above the saturation temperature

A superheater raises steam temperature above the saturation temperature at the prevailing pressure, producing dry superheated steam for turbines or process use. It does not raise the pressure above the saturation pressure.

Question 14: By what mechanism does a positive displacement pump move liquid?

  • A. By maintaining a positive suction pressure
  • B. By applying direct force to a confined volume of liquid
  • C. By centrifugal force
  • D. By gravitational force

Correct answer: By applying direct force to a confined volume of liquid

A positive displacement pump moves liquid by applying direct mechanical force to a confined volume : piston, gear, or diaphragm action trapping and expelling a fixed volume each cycle. It does not depend on centrifugal or gravitational force.

Question 15: What is a venturi meter used to measure?

  • A. The viscosity of a fluid such as ketchup
  • B. The level of water in a tank
  • C. The flow rate of liquid through a pipe
  • D. The pressure of gas in a pipe

Correct answer: The flow rate of liquid through a pipe

A venturi meter measures the flow rate of liquid through a pipe, using the pressure drop across a constricted throat (Bernoulli principle). It is not a viscometer, a tank-level gauge, or a gas-pressure gauge.

Question 16: The enthalpy of saturated steam is 2592.1 kJ/kg at 50°C and 2600.9 kJ/kg at 55°C. Estimate the enthalpy at 53°C by linear interpolation.

  • A. 2197.4 kJ/kg
  • B. 2397.4 kJ/kg
  • C. 2597.4 kJ/kg
  • D. 2797.4 kJ/kg

Correct answer: 2597.4 kJ/kg

Linear interpolation between 50 °C (2592.1 kJ/kg) and 55 °C (2600.9 kJ/kg): at 53 °C, h = 2592.1 + (3/5)(8.8) = 2592.1 + 5.28 = 2597.38, about 2597.4 kJ/kg.

Question 17: Air at a bulk temperature of 50°C flows over a steam-carrying tube of 0.01 m outside diameter. The heat transfer coefficient on the air side is 15 W/m²·°C and the tube surface temperature on the air side is 99°C. How much heat is transferred to the air per metre of tube length?

  • A. 12 W
  • B. 19 W
  • C. 23 W
  • D. 28 W

Correct answer: 23 W

Convective heat transfer follows Q = h·A·ΔT: Q = 15 × (π × 0.01 × 1) × (99 − 50) = 15 × 0.03142 × 49 ≈ 23.1 W per metre of tube length.

Question 18: The activation energy for vitamin C thermal destruction in a fruit juice was found to be 5 kcal/mol from rate constants measured between 60°C and 90°C. What is the z-value for this destruction reaction? (R ≈ 2 cal/mol·K)

  • A. 4.9 K
  • B. 111 K
  • C. 4974 K
  • D. 111353 K

Correct answer: 111 K

From Arrhenius kinetics, the z-value follows z = 2.303·R·T²/Ea. With Ea = 5000 cal/mol, R ≈ 2 cal/mol·K, and T ≈ 348 K (midpoint of 60, 90 °C): z ≈ 2.303 × 2 × 348²/5000 ≈ 111 K.

Question 19: A plant needs a 45% total-solids fruit juice concentrate but has only a 65% solids concentrate and a 15% solids single-strength juice in stock. In what ratio must the 65% concentrate and the 15% juice be blended to obtain the 45% product?

  • A. 3:2
  • B. 2:3
  • C. 1:1
  • D. 13:9

Correct answer: 3:2

By the Pearson square, parts of 65% concentrate to parts of 15% juice = (45 − 15):(65 − 45) = 30:20 = 3:2. Check: (3×65 + 2×15)/5 = 225/5 = 45%, the target solids.

Question 20: Estimate the specific heat of a food product containing 10% protein, 20% fat and 70% water.

  • A. 0.4 BTU/(lb·°F)
  • B. 0.72 BTU/(lb·°F)
  • C. 1.2 BTU/(lb·°F)
  • D. 0.8 BTU/(lb·°F)

Correct answer: 0.8 BTU/(lb·°F)

Using component specific heats : protein ≈ 0.475, fat ≈ 0.4, water = 1.0 BTU/(lb·°F): cp = 0.1(0.475) + 0.2(0.4) + 0.7(1.0) = 0.0475 + 0.08 + 0.7 ≈ 0.83, i.e. about 0.8 BTU/(lb·°F).