Documentation Quiz
GIFSQ ID: ART-1470
Test your knowledge with this free 20-question Documentation quiz from Food Laboratory Management, part of the GIFSQ…
What this quiz covers
Documentation is the centre of a laboratory quality system, and this quiz explains why: it gives consistency, so everyone does the work the same way, traceability, so every result links back to its inputs, and proof, so records show the procedure was followed. The quiz starts with the hierarchy, from the general to the specific: the quality manual at policy level, procedures describing who does what, work instructions and methods describing how each task is done, and finally the records and forms that capture what actually happened. Procedures say what to do; records prove it was done. The master list, a register of all controlled documents with their current versions and locations, is how the lab proves everyone is working from the current version, and every page of a controlled document carries its ID, version, date and page number, so any single page can be identified at a glance.
The rest of the quiz is the daily practice of keeping that system honest. Procedures are approved before issue by authorized personnel who understand the technical content. Changes go through a defined process of review, approval and communication, and obsolete versions are removed from points of use, because staff following an outdated procedure can produce wrong or unsafe work. Handwritten corrections use a single line through the error, with the correction, date and initials, keeping the original readable: never correction fluid, never scribbling. Each analytical run records sample IDs, method version, equipment, reagents, analyst, date and raw data, and raw data is never discarded, because it is what lets an independent reviewer repeat the calculations. Test reports carry the lab and sample identification, the method, results with units, dates and authorization, and an amended report is issued as a new version clearly marked as amending the original, with the reason stated. Records are kept for the period set by regulation, accreditation or contract, electronic records are protected from unauthorized change, and backups guard against the drive failure or cyber incident that could destroy irreplaceable evidence.
One idea runs through the set: if it is not written down, it did not happen
A laboratory lives or dies on its records, and this quiz keeps returning to the same test: could someone who was not there reconstruct what happened, from the procedure in force to the raw data behind the number? When the answer is yes, the system is working.
How to use this quiz
Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the rules, clauses and record-keeping habits a laboratory quality student is expected to know by heart.
Choose how you want to play
A short note: documentation in a laboratory quality system
Documentation is the backbone of a laboratory quality system: procedures say what to do, and records prove it was done. It brings consistency, traceability, and proof that the work followed the procedures. ISO/IEC 17025:2017 requires technical records and test reports with defined contents, and ISO 22000:2018 Clause 7.5 requires documented information to be controlled.
The hierarchy runs from the quality manual down through procedures and work instructions to records and forms. A master list registers every controlled document with its current version and location. Each page of a controlled document shows its ID, version, date and page number. Changes go through a set process: review, approval, then telling staff about the new version. A document review cycle keeps documents current with practice, regulations and standards.
Records must be legible and permanent, or they cannot serve as evidence. Handwritten corrections cross out the error once, add the fix, date and initials, and leave the original readable. Raw data is never discarded: it lets someone else re-check the calculations and look into odd results. Test reports carry the lab and sample details, the method, results with units, dates and authorisation; amended reports are issued as a new version stating the reason. Electronic records need protection from unauthorised change, and backup, because hardware failure or an accident could destroy irreplaceable data.
Remember: procedures say what to do and records prove it was done, so write it down right the first time.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: What is a master list of documents?
Correct answer: A register of all controlled documents with their current versions and locations
A master list (sometimes called a document register) lists every controlled document in the system together with its current version, approval status, and where copies are kept. It is how the laboratory proves everyone is working from the current version, and it is a standard requirement of document control under ISO/IEC 17025.
Question 2: What must be recorded for each analytical run?
Correct answer: Sample IDs, method version, equipment used, reagents, analyst, date, and raw data
Analytical runs must be fully traceable: the sample identities, the method version used, the equipment, the reagents, the analyst, the date, and the raw data all belong in the record. That combination lets anyone reconstruct the run and re-check the result.
Question 3: What is the relationship between procedures and records?
Correct answer: Procedures say what to do; records prove it was done
Procedures describe what must be done and how; records are the written proof that it was actually done, when, and by whom. Both are needed: a procedure nobody records is invisible to auditors, and a record without a procedure proves nothing was done consistently.
Question 4: What should a controlled document show on each page?
Correct answer: Document ID, version, date, and page number so its status is always clear
Every page of a controlled document must carry its identification, version, date, and page number (for example, page 2 of 7). That way anyone holding any single page can tell immediately whether it is the current version. ISO/IEC 17025 requires this unambiguous identification of document status.
Question 5: What is the document hierarchy in a typical lab quality system?
Correct answer: Quality manual, procedures, work instructions/methods, then records and forms
The usual hierarchy runs from the general to the specific: the quality manual at policy level, procedures describing who does what, work instructions and methods describing how each task is done, and finally the records and forms that capture what actually happened. Each level supports the one above it.
Question 6: What is an uncontrolled copy of a document?
Correct answer: A copy not tracked by document control, valid only at the moment of printing
An uncontrolled copy is a print or copy that document control does not track, so it may already be outdated and is valid only at the moment of printing. Uncontrolled copies must be identified as such so nobody treats them as current.
Question 7: How should handwritten corrections be made in lab records?
Correct answer: Single line through the error, with the correction, date, and initials, keeping the original readable
Cross out the error with a single line so the original entry stays readable, then write the correction alongside with the date and your initials. Never scribble over entries, erase them, or use correction fluid: the audit trail must show what was changed and why.
Question 8: Who should approve laboratory procedures before issue?
Correct answer: Authorized personnel who understand the technical content
Procedures must be reviewed and approved before issue by authorized personnel who understand the technical content, typically technical management. Approval by customers, cleaning staff, or interns would not provide competent review.
Question 9: Why must obsolete versions of documents be removed from points of use?
Correct answer: To prevent unintended use of outdated instructions
Obsolete versions have to be withdrawn from every point of use (or clearly marked) because staff following an outdated procedure can produce wrong or unsafe work. Stray old instructions at the bench are one of the commonest audit findings.
Question 10: How are changes to controlled documents managed?
Correct answer: Through a defined change process with review, approval, and communication of the new version
Changes go through a controlled process: proposal, review by competent people, approval, then communication of the new version and withdrawal of the old one. Sticky notes, verbal-only changes, or letting anyone edit at will would destroy version control.
Question 11: What information must a test report contain per ISO/IEC 17025?
Correct answer: Lab and sample identification, method, results with units, dates, authorization
Under ISO/IEC 17025, a test report must identify the laboratory and the sample, state the method used, give the results with their units, record the relevant dates, and carry authorization by the responsible person. Those are the minimum facts a customer needs to trust and use the result.
Question 12: Why should records be legible and permanent?
Correct answer: Illegible or fading records cannot serve as evidence of what was done
Records are evidence. If a record is illegible, smudged, or printed on paper that fades, it cannot prove what was done, and during an investigation or audit it is as good as missing. Recording what was done only works if the record survives in readable form.
Question 13: How should amended test reports be issued?
Correct answer: As a new version clearly marked as amending the original, with the reason stated
When an issued report must be changed, ISO/IEC 17025 (clause 7.8.8) requires the change to be made by issuing a further document that is clearly identified as an amendment to the original, with the reason for the change stated where appropriate. Quietly swapping the old report would hide the audit trail.
Question 14: How long should laboratory records be retained?
Correct answer: For the period defined by regulation, accreditation, or contract
There is no universal retention time: laboratory records must be kept for the period set by regulation, the accreditation body, or the customer contract. Keeping them 'until the shelf is full' or 'forever' is not an acceptable retention policy.
Question 15: Why must raw data never be discarded after results are calculated?
Correct answer: Raw data allows independent verification of calculations and investigation of anomalies
Raw data, such as instrument outputs, weighings, and plate counts, lets an independent reviewer repeat the calculations and trace back any anomaly. Once raw data is discarded, the reported result can never be verified, which is why data-integrity rules treat raw data as the core evidence.
Question 16: Why is documentation central to a laboratory quality system?
Correct answer: It provides consistency, traceability, and proof that procedures were followed
Documentation gives the laboratory consistency (everyone does it the same way), traceability (every result links back to its inputs), and proof (records show the procedure was followed). That is why it sits at the center of every laboratory quality system.
Question 17: Why are electronic records required to be protected from unauthorized changes?
Correct answer: Data integrity demands that records cannot be altered without detection
Data integrity means a record must be attributable and unalterable without detection. If electronic records could be changed silently, results could be falsified, so access controls, audit trails, and protection against unauthorized changes are mandatory.
Question 18: What is the purpose of a document review cycle?
Correct answer: To keep documents current with practice, regulations, and standards
Documents are reviewed on a defined cycle so they stay aligned with actual practice, current regulations, and current standards. A procedure that no longer matches what people really do is worse than useless: it creates nonconformities.
Question 19: Why must obsolete documents be removed or clearly marked?
Correct answer: To stop staff accidentally following outdated methods or using old forms
Old methods, superseded forms, and outdated procedures must be removed from circulation or clearly marked obsolete so staff do not accidentally use them. One wrong version used on the bench can invalidate a whole analytical run.
Question 20: Why is backup of electronic laboratory data essential?
Correct answer: Hardware failure, cyber incidents, or accidents could otherwise destroy irreplaceable records
Electronic records can vanish instantly: a failed drive, a cyber incident, or an accidental delete can destroy years of irreplaceable data. Regular, tested backups are the only protection, and accreditation bodies expect them.