Chromatography – Part 2 Quiz
GIFSQ ID: ART-0553
Questions on chromatography: how mixtures are separated and identified in the food lab. Round two on the…
HPLC, GC and TLC in practice
This set moves from chromatography basics into working practice: what HPLC can and cannot analyse, which carrier gases suit gas chromatography, how column efficiency relates to peak width, and how to read a thin-layer plate. It also covers the numbers analysts actually use, such as retention factor from a plate measurement and the void volume share of a gel filtration bed. These are bench-level questions, the kind that show up when a method leaves the textbook and meets a real sample. Gradient elution earns a mention beside isocratic work, since changing the mobile phase during a run can separate mixtures that a single fixed mixture would leave tangled.
Limits matter as much as strengths
Every chromatographic method has samples it handles badly, and knowing those limits prevents wasted runs. Elemental mercury in fish belongs to atomic absorption, not HPLC; a salty intravenous infusion is no job for gas chromatography; and a compound that will not dissolve in the mobile phase will not separate in HPLC at all. Questions here test those boundaries alongside the strengths, so a method’s ‘cannot’ list deserves as much study as its ‘can’ list.
How to use this set
Work each question as a bench decision: given this sample, which instrument would you actually book? Check solubility, volatility and charge before choosing, and use the numbers, Rf, void volume, molecular weight range, exactly as given. Notes below name the marked answer for every question and explain the practical reasoning.
Gas chromatography suits compounds that can be vaporised without falling apart, which covers many flavour volatiles and fatty acid derivatives. Liquid chromatography takes the rest: larger, fragile or non-volatile molecules that need a gentler ride. Choosing between them starts with the analyte’s volatility and stability, not with habit. Questions here often hide that choice inside a sample description, so read what the compound is before picking a technique.
Choose how you want to play
A short note: chromatography part 2
Chromatography part 2 covers HPLC, gas chromatography and the numbers behind a separation. HPLC stands for high pressure liquid chromatography, also called high performance liquid chromatography. The mobile phase is any liquid in which the sample dissolves, and the solvent that carries the analyte is called the eluent. Column efficiency, expressed as theoretical plates, rises as peak width falls: plate number grows with the square of retention time over the square of peak width.
Gas chromatography separates by differences in partition coefficients, and helium is the preferred carrier gas because it is inert. It cannot analyse everything: elemental mercury in fish and intravenous sodium chloride are outside its reach, since GC needs volatile or volatilizable compounds. In reverse-phase chromatography the stationary phase is non-polar, typically C18 chains, and the wanted protein comes off when solutions of different hydrophobicity or ionic strength wash through.
In TLC, Rf is the compound's distance over the solvent's distance: 1.7 cm over 5.0 cm gives 0.34. Sephadex G-10 gel separates compounds below about 700 daltons, and the empty volume of a gel filtration column is about one third of the bed volume. In ion exchange chromatography weakly charged compounds elute first, and Tris is the usual buffer for anion exchange. Affinity chromatography can isolate enzymes, antibodies and other targets through specific binding, and chromatography on a solid stationary phase is adsorption chromatography.
Practical takeaway: check volatility before choosing GC, and read Rf as compound distance over solvent distance.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: Which cannot be analysed with HPLC?
Correct answer: Determining mercury in a fish sample
HPLC needs compounds that dissolve and interact with the phases : elemental mercury in fish is determined by cold-vapour atomic absorption, not by liquid chromatography. Pigments, pesticides and caffeine are all routine HPLC analyses.
Question 2: In reverse-phase chromatography, what is the stationary phase made of?
Correct answer: Non-polar material
Reverse-phase chromatography uses a non-polar stationary phase : typically C18 chains bonded to silica : with a polar mobile phase. The non-polar surface is what retains non-polar compounds longest.
Question 3: What is the basis of chromatography for separating mixture components?
Correct answer: The interaction of the components with both stationary and mobile phases
Separation happens because each component interacts differently with both the stationary and the mobile phase : partitioning, adsorbing or exchanging at its own rate. Magnetic deflection, electric fields and infrared absorption are not the basis of chromatography.
Question 4: Which assay could NOT be done by gas chromatography?
Correct answer: Analyzing intravenous sodium chloride infusion
Gas chromatography needs volatile or volatilizable compounds : intravenous sodium chloride solution is just salt water with no volatile analytes to separate. Volatile oils, drugs in body fluids and drug-synthesis materials are all classic GC work.
Question 5: HPLC stands for what?
Correct answer: Both High Pressure and High Performance Liquid Chromatography
HPLC has carried both names in its history: high pressure described the early pumps, high performance the results. Both expansions of the acronym are in real use, which is why the combined answer is the complete one.
Question 6: Column efficiency, expressed as the number of theoretical plates, relates to peak width how?
Correct answer: Inversely related to the square of peak width
Theoretical plate number grows as retention time squared divided by peak width squared : narrower peaks mean higher efficiency. The inverse-square relationship with peak width is the standard plate-count equation.
Question 7: What can serve as a mobile phase in HPLC?
Correct answer: Any liquid in which the sample dissolves
The HPLC mobile phase must be a liquid that dissolves the sample, so the analytes can travel through the column. Solids and insoluble compounds cannot flow through the system as a mobile phase.
Question 8: Helium is generally preferred over nitrogen and hydrogen as a GC carrier gas because of what?
Correct answer: It is inert
Helium is inert and non-flammable, so it cannot react with analytes or the column at high temperature : hydrogen's flammability is the practical concern with the alternative. Helium is not the cheapest option; its safety and inertness are the point.
Question 9: Which statement about column chromatography is correct?
Correct answer: In reverse-phase chromatography the wanted protein can be eluted by solutions of different hydrophobicity or ionic strength
In reverse-phase chromatography the wanted protein can be released by changing the mobile phase's hydrophobicity or ionic strength, weakening its grip on the non-polar surface. Ion exchange and gel filtration do not separate by size or by specific ionic groups in the way the wrong options claim.
Question 10: In a TLC run, the compound travels 1.7 cm and the solvent 5.0 cm. What is the Rf value?
Correct answer: 0.34
The Rf value is the distance the compound travelled divided by the distance the solvent travelled: 1.7 divided by 5.0 is 0.34. Values above 1 are impossible for an Rf, which is why 2.94 is out.
Question 11: What is the solvent that carries the analyte called?
Correct answer: Eluent
The eluent is the solvent that carries the analyte through the column : the fresh mobile phase entering the system. The eluate is what comes out the other end, and the solute is the dissolved substance itself.
Question 12: A separation where the mobile phase composition stays constant is called what?
Correct answer: Isocratic elution
Isocratic elution holds the mobile phase composition constant throughout the run. Gradient elution deliberately changes it, and isostatic is not the standard term.
Question 13: Sephadex G-10 gel separates compounds of which molecular weight range?
Correct answer: Below 700
Sephadex G-10 has small pores that exclude molecules above about 700 daltons, so it separates only low-molecular-weight compounds. Larger proteins pass straight through with the void volume.
Question 14: The void volume of a gel filtration column should be about what share of the bed volume?
Correct answer: One third
The void volume : the space between the beads : is roughly one third of the total bed volume in a packed gel column. It is the volume in which excluded molecules elute.
Question 15: In ion exchange chromatography, which compounds elute first?
Correct answer: Weakly charged
In ion exchange, the most strongly charged compounds bind tightest and elute last; weakly charged ones are held loosely and come off first. Neutral molecules do not interact with the exchanger at all.
Question 16: Which buffer is used for anion exchange chromatography?
Correct answer: Tris
Tris is the standard buffer for anion exchange chromatography: as a cationic buffer it does not compete with anions for the positively charged exchanger sites. The acidic buffers listed would interfere with the separation.
Question 17: In gas chromatography, separation is based on differences in which property?
Correct answer: Partition coefficients
Gas chromatography separates on differences in partition coefficients : how each compound divides itself between the mobile gas and the stationary phase. Conductivity and molarity are not the basis of the separation.
Question 18: What can affinity chromatography isolate?
Correct answer: All of these
Affinity chromatography is remarkably versatile: immobilized ligands can capture enzymes, antibodies bound to antigen columns, and many other specific binders : all of these are real applications.
Question 19: What is chromatography with a solid stationary phase called?
Correct answer: Adsorption chromatography
Chromatography with a solid stationary phase is adsorption chromatography : solutes adsorb and desorb from the solid surface. The other names are not standard classifications.
Question 20: What does chromatography separate?
Correct answer: Mixtures
Chromatography separates mixtures : the components of a mixed sample. It works on mixtures of molecules, which is why the mixture option is the correct general answer.