Accreditation Quiz
GIFSQ ID: ART-1460
Test your knowledge with this free 20-question Accreditation quiz from Food Laboratory Management, part of the GIFSQ…
What this quiz covers
Accreditation is formal third-party recognition that a laboratory is competent to perform specific tests, and this quiz explains how that recognition is earned, kept and lost. It opens with the scope of accreditation, the defined list of tests, matrices and methods the accreditation actually covers, and the assessment itself: an on-site evaluation by assessors who review documents, observe tests and interview staff, with technical assessors who are experts in the laboratory’s own testing fields judging technical competence. Before an assessment the laboratory prepares with internal audits, a review of corrective actions, and current records and proficiency testing, and any nonconformities found must be corrected within a deadline, with evidence, before accreditation is granted.
The middle of the set covers life after accreditation is granted. The accreditation body keeps watching through ongoing surveillance, handles complaints about the laboratory, and enforces the rules on scope and logo use, so the accreditation mark may appear only on reports for accredited tests within scope. Accredited laboratories are reassessed periodically, typically with annual surveillance and a full reassessment every few years, and proficiency testing keeps demonstrating competence between assessments. Major changes in ownership, key staff, location or scope must be reported to the body because they can affect competence, and if a key authorised signatory is lost, a replacement must be designated and qualified promptly and the body informed if required.
Accreditation is not certification, and it is not approval
The distinction the quiz keeps returning to is that accreditation attests technical competence for specific tests, while certification, such as ISO 9001, covers the management system, and approval by a regulator is legal permission to operate. That is why regulators and customers prefer accredited laboratories: accreditation gives independent assurance of competence and reliable results. The ILAC Mutual Recognition Arrangement extends that assurance across borders, so results from accredited laboratories are accepted internationally. The stakes are real too: serious complaints or concerns about competence or integrity can trigger an unannounced visit, a laboratory must never claim accreditation for tests outside its scope, and suspension is a temporary withdrawal during which the laboratory must not issue accredited reports. The business value is plain: credibility that wins customer trust, regulatory acceptance and market access.
How to use this quiz
Take the quiz cold first, then read the short note below the player. It covers laboratory accreditation, in plain words, so a wrong answer still teaches you the terms and the habits.
Choose how you want to play
A short note: laboratory accreditation
Laboratory accreditation is formal recognition by an independent body that a food testing laboratory is competent to run named tests and methods inside a defined scope, under ISO/IEC 17011:2017. It differs from certification: certification confirms a management system, while accreditation attests technical competence for specific tests.
An accreditation body grants accreditation after an on-site assessment. Before it, the lab runs internal audits, closes corrective actions and checks records are current. Assessors then review documents, watch tests and interview staff. Technical assessors bring expertise in the lab's testing fields. When assessors record nonconformities, the laboratory must correct them and show evidence inside a set deadline.
Accreditation does not end at the grant. ISO/IEC 17011:2017 requires surveillance and reassessment, yearly surveillance visits and a full reassessment every few years. Serious complaints can trigger an unannounced visit. Laboratories must report changes to ownership, key staff, premises or scope. Proficiency testing under ISO/IEC 17025:2017 Clause 7.7 shows competence between visits.
The accreditation mark may appear only on reports for tests inside the scope. Claims outside the scope are not allowed. Suspension is a temporary withdrawal, and during suspension the laboratory must not issue accredited reports. A lost authorised signatory needs a qualified replacement at once.
Accredited results travel: under the ILAC Mutual Recognition Arrangement, signatory bodies accept each other's accredited results. That shared acceptance wins trust and markets.
Before you trust a lab report, check the test is on the lab's published scope of accreditation.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: What is the accreditation body's role after granting accreditation?
Correct answer: Ongoing surveillance, handling complaints about the lab, and enforcing scope and logo-use rules
The accreditation body's role does not end at the grant decision. ISO/IEC 17011:2017 requires the body to run surveillance and reassessment activities, handle complaints about accredited bodies, and enforce rules on the scope and on logo or mark use, up to suspending or withdrawing accreditation when the conditions are not met. Ongoing oversight is what keeps the accreditation credible over time.
Question 2: What is the difference between accreditation and approval by a regulator?
Correct answer: Accreditation is third-party competence recognition; approval is legal permission to operate
Accreditation, as defined in ISO/IEC 17011:2017, is formal third-party attestation of a body's competence to perform specific conformity assessment tasks. Regulatory approval, by contrast, is a legal permission to operate granted by an authority under applicable law. One recognises competence; the other authorises an activity.
Question 3: What is the ultimate business value of accreditation for a food lab?
Correct answer: Credibility that wins customer trust, regulatory acceptance, and market access
Independent recognition of competence under ISO/IEC 17011 and the ILAC Mutual Recognition Arrangement lets customers and regulators accept a laboratory's results without re-testing, which is why accredited labs win tenders and export market access. That credibility effect, rather than any operational perk, is the lasting commercial return on accreditation.
Question 4: What is the ILAC MRA?
Correct answer: ILAC's Mutual Recognition Arrangement: results from accredited labs are accepted internationally
The ILAC Mutual Recognition Arrangement is a multilateral agreement among accreditation bodies worldwide under which each signatory recognises the accreditations granted by the others. Its practical effect is that test results from an accredited laboratory are accepted internationally by other signatories' regulators and customers. ILAC maintains the list of signatory bodies and the arrangement's scope.
Question 5: Why must accredited labs notify the accreditation body of major changes?
Correct answer: Changes in ownership, key staff, location, or scope can affect competence and must be evaluated
ISO/IEC 17011:2017 obliges accreditation bodies to control changes that could affect an accredited body's competence or scope, so the laboratory must report changes of ownership, key personnel, premises, or activities. The body then evaluates whether competence is maintained before allowing the change to stand. Silence would leave the accreditation statement untrue.
Question 6: What is proficiency testing's role in maintaining accreditation?
Correct answer: Ongoing satisfactory PT demonstrates continued competence between assessments
ISO/IEC 17025:2017 (clause 7.7) requires laboratories to monitor the validity of results, including participation in proficiency testing or interlaboratory comparisons. A record of satisfactory PT between assessment visits is the body's evidence that competence is being maintained, not just claimed. It is a condition of continued accreditation, not only of the first grant.
Question 7: What typically triggers an unannounced accreditation visit?
Correct answer: Serious complaints or concerns about the lab's competence or integrity
ISO/IEC 17011:2017 gives accreditation bodies the right to carry out extraordinary assessments when there are serious complaints or other concerns about an accredited body's competence or integrity. These visits are deliberately unannounced so assessors see normal practice. They are not routine scheduling and are never requested by laboratory staff.
Question 8: Who are technical assessors in accreditation?
Correct answer: Experts in the lab's testing fields who evaluate technical competence
Assessment teams include technical assessors chosen for their expertise in the specific testing fields under evaluation, so they can judge the laboratory's methods, equipment, and staff competence first-hand. Lawyers, accountants, and salespeople lack the technical depth the task demands. Competent assessment is itself a requirement of ISO/IEC 17011:2017.
Question 9: What is the scope of accreditation?
Correct answer: The defined list of tests, matrices, and methods the accreditation covers
The scope of accreditation is the formally defined list of tests, matrices, and methods that the accreditation covers : for example, lead in milk powder by ICP-MS : not everything the laboratory happens to do. ISO/IEC 17011:2017 requires the body to define and publish this scope precisely. Anything outside it is not accredited.
Question 10: How does accreditation differ from certification (e.g., ISO 9001)?
Correct answer: Accreditation attests technical competence for specific tests; certification covers the management system
Accreditation attests that a body is technically competent to perform specific conformity assessment tasks, whereas ISO 9001 certification only confirms that an organisation runs a compliant management system. A certified company can still be technically wrong; an accredited laboratory has demonstrated competence in the actual tests. Neither is self-declared : both involve outside audit, but of different things.
Question 11: What should a lab do if it loses a key authorized signatory?
Correct answer: Designate and qualify a replacement promptly and inform the accreditation body if required
Authorised signatories are part of the competence the accreditation covers, so losing one must be handled promptly: designate and qualify a replacement and inform the accreditation body where its rules require notification. Reporting accredited results without an authorised signatory would invalidate the claim. This follows ISO/IEC 17025:2017's controls on personnel competence (6.2) and on reporting (7.8).
Question 12: What is laboratory accreditation?
Correct answer: Formal third-party recognition that a lab is competent to perform specific tests
ISO/IEC 17011:2017 defines accreditation as third-party attestation related to a conformity assessment body, conveying formal demonstration of its competence to carry out specific conformity assessment tasks. It is therefore a recognition of competence, not a tax document, a marketing prize, or a building permit. The recognition is granted only after assessment against criteria such as ISO/IEC 17025.
Question 13: How should the accreditation mark be used on test reports?
Correct answer: Only on reports for accredited tests within scope, per the body's rules
ILAC P8:07/2019 restricts use of the accreditation symbol to reports on activities within the accredited scope and subjects it to the accreditation body's rules. Putting the mark on out-of-scope reports or on business cards would mislead customers about what was independently assured. The mark signals a specific, verifiable claim.
Question 14: Why do regulators and customers prefer accredited labs?
Correct answer: Accreditation provides independent assurance of competence and reliable results
Regulators and customers cannot repeat every test themselves, so they rely on accreditation as independent, third-party assurance that the laboratory is competent and its results reliable. That assurance is grounded in ISO/IEC 17011:2017's requirements for how accreditation bodies assess and monitor laboratories. Speed, price, or location are not what accreditation certifies.
Question 15: What preparation should a lab do before an assessment?
Correct answer: Conduct internal audits, review corrective actions, make sure records and PT are current
A laboratory about to be assessed should confirm its house is in order: internal audits completed with corrective actions closed, staff records and training current, equipment calibration up to date, and proficiency testing participation satisfactory. These are exactly the records assessors sample under ISO/IEC 17025:2017. Cosmetic fixes such as repainting do nothing for competence.
Question 16: What happens if nonconformities are found during assessment?
Correct answer: The lab must correct them within a deadline with evidence before accreditation is granted
When assessors record nonconformities, ISO/IEC 17011:2017 requires the body to set a timeframe for the laboratory to correct them and provide evidence before accreditation is granted or maintained. The laboratory : not the assessor : must do the correction. Ignoring findings or granting accreditation automatically would break the assurance chain.
Question 17: Can a lab claim accreditation for tests not on its scope?
Correct answer: No, claims must be limited to the accredited scope to avoid misleading customers
Because the accreditation mark and claims are tied to the published scope, ILAC P8:07/2019 prohibits claims of accreditation for tests outside it : on the website, verbally, or anywhere else. Out-of-scope claims mislead customers into believing independent assurance exists where it does not. The correct statement for non-accredited work is simply that it is not accredited.
Question 18: What is suspension of accreditation?
Correct answer: Temporary withdrawal of accreditation, during which the lab must not issue accredited reports
Suspension is the temporary withdrawal of accreditation: during suspension the laboratory must not issue reports bearing the accreditation mark or claim accredited status. It is imposed when conditions for accreditation are not met, and it ends only when the body is satisfied. It is neither a celebration, a promotion, nor a vacation.
Question 19: What is an accreditation assessment?
Correct answer: An on-site evaluation by assessors reviewing documents, observing tests, and interviewing staff
An accreditation assessment is an on-site evaluation in which assessors review the management system documents, observe tests being performed, and interview staff to verify competence against criteria such as ISO/IEC 17025:2017. It is a structured technical review, not a friendly chat, a phone call, or a written exam for all staff.
Question 20: How often are accredited labs reassessed?
Correct answer: Periodically, typically with annual surveillance and full reassessment every few years
ISO/IEC 17011:2017 requires accreditation bodies to monitor accredited bodies between grant and expiry, which in practice means annual surveillance visits with a full reassessment every few years (commonly a four-year cycle). Accreditation is therefore never permanent and never decades-long without review. Each cycle re-verifies continued competence.