Unit 9: Allergen Testing and Detection: ELISA, PCR and LC-MS
GIFSQ ID: FTN-0159
Unit 9 of 10 in Food Allergen Management. This page is one unit of the Food Allergen Management notes.
All units in Food Allergen Management:
- Unit 1: The Major Allergens and Why They Matter
- Unit 2: How Allergy Works: The Immune Response
- Unit 3: Cross-Contact: Where It Happens and How to Stop It
- Unit 4: Allergen Labelling: What Must Be Declared
- Unit 5: Allergen Control in the Factory: Cleaning, Segregation, Validation
- Unit 6: Allergen Incidents and Recalls: Learning from Them
- Unit 7: Serving Allergic Customers: Food Service
- Unit 8: Allergen Risk Assessment and Threshold Doses
- Unit 9: Allergen Testing and Detection: ELISA, PCR and LC-MS
- Unit 10: Allergen Management in the Supply Chain and Allergen-Free Product Development
Previous unit: Unit 8: Allergen Risk Assessment and Threshold Doses | Next unit: Unit 10: Allergen Management in the Supply Chain and Allergen-Free Product Development
Unit 9: Allergen Testing and Detection: ELISA, PCR and LC-MS
Note
A question to start with
A factory has cleaned a line, run a plain biscuit after a peanut biscuit, and sent a sample to the laboratory. The laboratory report comes back with a number: peanut protein, 4 mg/kg. The quality manager looks at the number and asks three questions. Is the number right? What did the test actually measure? And would a different test have given a different number? Those three questions are the heart of allergen testing. A test result is only as good as the test behind it, and different tests measure different things: one measures protein, one measures DNA, and one measures the pieces of a protein after it has been broken apart. This unit explains the three main methods, what each one can and cannot do, and how to read a laboratory report without being misled by it.
Testing is where allergen management meets the laboratory, and the meeting is not always comfortable. The factory wants a simple answer, yes or no, present or absent. The laboratory gives a number with a limit, a range, and a note about what the test could not see. Learning to live with that number, and to use it well, is a skill. A manager who treats a "not detected" result as proof of absence will be caught out. A manager who understands detection limits, cross-reactivity, and sampling will use the same result to make a sound decision. This unit builds that understanding, with worked examples that use round teaching numbers, clearly marked as examples, so the arithmetic can be followed without mistaking the numbers for real limits.
Questions to think about
- A test finds no peanut in a biscuit. Does that prove the biscuit contains no peanut?
- A test that looks for peanut DNA finds peanut DNA, but the food was made with highly refined peanut oil. Has the test found a real risk?
- Two laboratories test the same biscuit and give different numbers. How can both be right?
Think about the two laboratories question before you read on
Both can be right because they used different tests, or the same test in a different way. One may measure total peanut protein and the other may measure one peanut protein only. One may extract the protein with one liquid and the other with a different liquid. One may test a sample from the start of the run and the other from the end. The number belongs to the method and the sample, not only to the food, and that is why a report must name the method.
Why testing matters, and what it cannot do
Testing has four jobs in allergen management. The first is checking raw materials: does this spice mix, this flour, or this chocolate contain the allergen the supplier says it does not? The second is validating cleaning: after cleaning, is the allergen gone from the surface, and is it gone from the first food made after cleaning? The third is checking finished foods: does this batch contain the allergen it should not contain, and at what level? The fourth is investigating a problem: after a complaint or an incident, where did the allergen come from, and how much was there? Each job needs a different sample, a different test, and a different reading of the result, and a test chosen for one job may be wrong for another.
Testing also has limits that must be stated plainly. A test measures the sample that was sent, not the whole batch, and a biscuit from the start of a run may differ from a biscuit from the end. A test has a limit below which it cannot see, so "not detected" means "below the limit of this test", never "zero". A test can be fooled by the food itself: chocolate, spices, and foods rich in fat or polyphenols can hide protein from a test, or can make a test read high. A test measures what it was built to measure, and a protein test cannot tell you about DNA, while a DNA test cannot tell you how much protein is present. A manager who knows these limits will ask for the right test, take the right sample, and read the report with care. A manager who does not will be surprised, and the surprise will come at the worst time.
Sampling is half the testing, and it is the half most often done badly. A sample must represent the food it stands for. For a surface, that means swabbing the places where allergen hides: corners, joints, dead legs in pipes, the underside of a mixer blade, and the first product through the line. For a batch of biscuits, that means taking biscuits from the start, the middle, and the end of the run, and from more than one tray, because allergen is rarely spread evenly. For a delivery of flour, that means taking scoops from more than one sack. The laboratory can only test what it is given, and a neat sample taken from the cleanest place gives a neat result that says nothing about the rest of the batch. The sampling plan is written down before the sample is taken, with where, when, how much, and by whom, and the plan is kept with the result.
ELISA: the workhorse that measures protein
ELISA is the most widely used allergen test in food factories, and its full name, enzyme-linked immunosorbent assay, describes what it does. An antibody, a protein made by the immune system that binds to one target, is fixed to a surface. The food sample is prepared, usually by mixing it with a liquid that pulls the allergen protein out of the food, and the liquid is added to the surface. If the allergen protein is present, it binds to the antibody. A second antibody, linked to an enzyme, is added, and it binds too, forming a sandwich with the allergen protein in the middle. A chemical is added that the enzyme turns into a coloured product, and the depth of colour is measured with an instrument. The deeper the colour, the more allergen protein was present. That is the whole method in one paragraph, and every ELISA kit on the market is a version of it.
ELISA is popular because it is fast, it can be run in a factory laboratory or sent to an outside laboratory, it measures protein, which is the hazard, and it can measure low levels, often down to a few milligrams of protein per kilogram of food. It is also popular because it is specific: an antibody made for peanut protein should bind to peanut protein and not to other proteins. That specificity is also its weakness. If the food has been heated, roasted, or fermented, the protein may have changed shape, and the antibody may bind less well, or not at all, so the test reads low even though the protein is still there. If the food contains a protein that looks like the target, such as a legume protein that looks like peanut protein to the antibody, the test can read high. This is called cross-reactivity, and the kit maker should state which foods cross-react and how much.
Reading an ELISA result means reading the calibration with it. The laboratory runs a set of standards, samples with known amounts of allergen protein, and measures the colour for each one. The results form a standard curve, a line or curve that links colour to amount. The colour of the unknown sample is read off that curve to give its amount. Two numbers on the report matter most. The limit of detection, LOD, is the lowest amount the test can reliably tell apart from zero. The limit of quantification, LOQ, is the lowest amount the test can measure with acceptable accuracy, and it sits above the LOD. A result below the LOD is reported as "not detected". A result between the LOD and the LOQ is reported as detected but not reliably measured. A result above the LOQ is given as a number. A manager who asks only "was it detected?" misses the difference between these three, and the difference matters for the decision that follows.
A worked example shows the arithmetic, with round teaching numbers only. Suppose a laboratory runs peanut standards at 0, 1, 2, 5, and 10 mg/kg, and the colour readings rise in step with the standards. A sample gives a colour that falls between the 2 and 5 mg/kg standards, and the curve reads it as 3 mg/kg. Suppose the kit states an LOD of 0.5 mg/kg and an LOQ of 1 mg/kg. The result of 3 mg/kg is above the LOQ, so it is reported as a number, 3 mg/kg. If the same sample had read 0.7 mg/kg, it would be above the LOD but below the LOQ, so it would be reported as detected but not quantified. If it had read 0.3 mg/kg, it would be below the LOD, and reported as not detected. The same sample, the same kit, and three different ways of reporting, depending on where the number falls. That is why the report must be read whole, not as a single word.
ELISA also comes in two forms that are easy to mix up. A quantitative ELISA gives a number, as above, and needs a standard curve, a calibrated reader, and a trained operator. A qualitative lateral flow test, the strip test that looks like a pregnancy test, gives a yes or no answer in minutes, and is used on the factory floor to check a surface or a rinse water. The strip is fast and simple, and it is also less sensitive and less exact than a laboratory ELISA, and it must never be used as a substitute for a laboratory result when a number is needed for a risk assessment. The strip answers "is there enough to see?" and the laboratory answers "how much is there?" Those are different questions, and the factory needs both, in their proper places.
PCR: finding DNA when protein is hard to see
PCR, the polymerase chain reaction, does not measure protein at all. It measures DNA. It copies a short piece of DNA that is characteristic of the allergen source, such as peanut DNA or soy DNA, doubling it again and again until there is enough to see. If the DNA is present, it is copied, and the test is positive. If it is absent, nothing is copied, and the test is negative. Because PCR copies DNA, it can detect very small amounts, and it works even when the protein has been changed by heat or processing, as long as the DNA is still there to copy. That makes it useful for foods where ELISA struggles, such as foods that have been heavily heated, fermented, or refined.
The strength of PCR is also its limit. DNA is not the hazard: protein is. Finding peanut DNA in a food shows that peanut was there, or that something from a peanut plant was there, but it does not say how much peanut protein is present, and it does not say whether that protein can cause a reaction. Highly refined peanut oil may carry peanut DNA in trace amounts while carrying almost no protein, so a PCR positive and an ELISA negative can both be true at once, and the risk assessment must decide which one matters. In that case the protein result, the ELISA, is the one that speaks to the hazard, and the DNA result speaks to the history of the food, to where its ingredients came from. A manager who treats a PCR positive as proof of a dangerous food will throw away safe food. A manager who ignores a PCR positive will miss the clue that a supplier's material has changed.
PCR also needs care in the laboratory, because the very thing that makes it powerful, its ability to copy tiny amounts of DNA, makes it easy to contaminate. A speck of dust carrying peanut DNA, a pipette used twice, or a sample handled after a peanut sample, can give a false positive. Good laboratories run blank samples, samples with no food in them, alongside the real samples, to catch contamination, and they run positive and negative controls with every batch. The report should state the controls and the result for each one. A report with no controls is a report that cannot be trusted, however neat its numbers look.
LC-MS: the confirmatory method that reads protein pieces
LC-MS, liquid chromatography coupled to mass spectrometry, is the most exact of the three methods, and the one most often used to confirm a result that matters. Its logic is different from ELISA and PCR. First, the proteins in the food are broken into short pieces, called peptides, with an enzyme that cuts protein at known places. Then the peptides are separated by liquid chromatography, which sorts them by their chemistry, so they come out one after another. Then the mass spectrometer weighs each peptide, with great exactness, and reads its pattern, which is like a fingerprint for the protein it came from. If the fingerprint matches a known peanut peptide, the test says peanut protein is present, and the size of the signal says how much.
LC-MS has three strengths that make it the confirmatory method. It is specific: it reads the fingerprint of the peptide, not a colour that any protein could produce, so cross-reactivity is rare. It can measure more than one allergen at a time: a single run can look for peanut, milk, egg, soy, and wheat peptides together. And it works on processed foods where ELISA struggles, because it looks for short peptides that survive heating and processing better than whole proteins do. Its weaknesses are cost, time, and skill. The instrument is expensive, the run takes longer than an ELISA, the sample preparation is more involved, and the result needs a trained analyst to read it. For that reason LC-MS is used to confirm, to settle a dispute, or to measure a low level with confidence, rather than for routine daily checks.
The three methods are often used together, and the combination is stronger than any one alone. A factory might use a strip test on the floor to check cleaning, a laboratory ELISA to measure the level in the first product, a PCR test to check whether a raw material carries the allergen source at all, and an LC-MS run to confirm a result that would change a label or trigger a recall. Each method answers a different question, and the manager who knows which question each one answers will not ask ELISA to do PCR's job, or PCR to do ELISA's job. The testing plan, written down with the method for each job, the sampling plan, and the laboratory, is part of the allergen management plan, and it is reviewed when a new food, a new supplier, or a new process arrives.
The diagram shows how to choose a test by the question being asked. The most common error is choosing the test first and the question second, which gives an answer to a question nobody asked.
Reading a laboratory report without being misled
A laboratory report has five parts that must all be read. The first is the sample: what was sent, when it was taken, from where, and how much. If the sample is not described, the result cannot be tied to a batch. The second is the method: which test, which kit, and which version, because an ELISA kit for peanut from one maker is not the same as one from another. The third is the result, with its unit, such as mg/kg, and its basis, such as milligrams of protein per kilogram of food, or milligrams of peanut per kilogram, which are not the same thing, because peanut is not all protein. The fourth is the LOD and LOQ, which say what the test could and could not see. The fifth is the controls and the notes: whether the blanks were clean, whether the standards behaved, and whether the food interfered with the test.
Two traps catch even careful readers. The first is the unit trap. One laboratory may report milligrams of peanut per kilogram, while another reports milligrams of peanut protein per kilogram. Peanut is roughly one quarter protein, so 4 mg/kg of peanut protein is not the same as 4 mg/kg of peanut. The report must state which one it is, and the risk assessment must use the protein number, because protein is the hazard. The second is the "not detected" trap. "Not detected" means below the LOD of that test, on that sample, on that day. It does not mean zero, and it does not mean the next sample will also be below the LOD. A manager who writes "peanut free" on the basis of one "not detected" result has written a promise the test never made.
Results also vary between laboratories, and the variation has reasons. Different kits use different antibodies, which bind to different proteins. Different extraction liquids pull different amounts of protein out of the food. Different analysts prepare the sample in different ways. The same sample tested in two laboratories can give results that differ by a factor of two or more, and both can be right within their own method. The cure is to use one laboratory and one method for trend work, so that changes over time mean something, and to send the same sample to a second laboratory, with LC-MS, only when a result must be confirmed. The report is kept, with the sampling plan, so that a later reader can see what was done and why.
Practical note: The next time you see a laboratory report, read it in this order: sample, method, unit, LOD and LOQ, then the number. Then ask one question: does the number answer the question I asked when I sent the sample? If it does not, the next step is not to argue with the number. It is to send a new sample, with a clear question, to the right test.
Quick self-check
Question: A laboratory reports peanut protein as "not detected". What does that mean?
It means the amount was below the limit of detection of that test, on that sample, on that day. It does not mean zero, and it does not prove the whole batch contains no peanut protein.
Question: A food made with highly refined peanut oil gives a PCR positive for peanut DNA but an ELISA negative for peanut protein. Which result speaks to the hazard, and why?
The ELISA result speaks to the hazard, because the hazard is the protein, and ELISA measures protein. The PCR result shows that peanut DNA was present, which speaks to the history of the ingredient, but DNA on its own is not the hazard.
Try it yourself
Find a laboratory report, a worked example in a textbook, or a kit instruction sheet, and read it with the five-part check from this unit: sample, method, unit, LOD and LOQ, then the number. Write down each part in your own words, and then write one line saying what decision the number supports, and one line saying what decision it does not support. If you cannot find a real report, take the worked example in this unit, the sample that read 3 mg/kg, and write the same five parts for it, with the LOD of 0.5 mg/kg and the LOQ of 1 mg/kg. That exercise, done once with care, is the habit that stops a "not detected" result from becoming a false promise.
Key ideas to carry forward
- Testing has four jobs: checking raw materials, validating cleaning, checking finished foods, and investigating a problem, and each job needs its own sample and test.
- Sampling is half the testing: a sample must represent the batch, the surface, or the delivery it stands for, and the plan is written down before the sample is taken.
- ELISA measures protein with antibodies, a standard curve, a limit of detection, and a limit of quantification, and it can be fooled by heat-changed protein and by cross-reactivity.
- PCR measures DNA, not protein, and it can find an allergen source after heavy processing, but a DNA positive does not by itself prove a protein hazard.
- LC-MS reads the fingerprints of protein pieces, is specific and can measure several allergens at once, and is used to confirm a result that matters.
- A report must be read whole: sample, method, unit, LOD and LOQ, controls, and notes, and "not detected" means below the limit of this test, never zero.
- Results vary between laboratories and methods, so trend work uses one laboratory and one method, and a result that changes a label is confirmed.
Glossary
ELISA
A laboratory test that uses antibodies to measure the amount of a protein, such as an allergen protein, in a food. Food tech example: an ELISA on a biscuit measures peanut protein in milligrams per kilogram.
Antibody
A protein that binds to one target, used in tests to pick out one allergen protein from a food. Food tech example: an antibody made for milk protein binds to milk protein in a sauce and not to other proteins.
Standard curve
A set of samples with known amounts, used to link a test reading, such as colour, to an amount. Food tech example: the colour of a biscuit sample is read off the standard curve to give its peanut protein in mg/kg.
Limit of detection (LOD)
The lowest amount a test can reliably tell apart from zero. Food tech example: an ELISA with an LOD of 0.5 mg/kg reports a sample below that as not detected.
Limit of quantification (LOQ)
The lowest amount a test can measure with acceptable accuracy, sitting above the LOD. Food tech example: a sample that reads between the LOD and the LOQ is reported as detected but not reliably measured.
Cross-reactivity
A test reacting to a protein that looks like its target, giving a reading that is too high. Food tech example: an antibody for peanut may cross-react with another legume protein in a food.
Lateral flow test
A strip test that gives a yes or no answer in minutes, used on the factory floor to check a surface or a rinse. Food tech example: a lateral flow strip checks whether a cleaned mixer still carries milk protein.
PCR
A test that copies a short piece of DNA again and again until it can be seen, used to find the DNA of an allergen source. Food tech example: PCR finds soy DNA in a food even after the soy protein has been changed by heating.
DNA
The material in cells that carries the instructions for a living thing, and that PCR copies to find an allergen source. Food tech example: peanut DNA in a sample shows that material from a peanut plant was present.
LC-MS
A method that separates protein pieces and weighs them with great exactness, used to confirm allergen results. Food tech example: LC-MS confirms a peanut result by reading the fingerprint of a peanut peptide.
Peptide
A short piece of a protein, made when a protein is broken apart, and read by LC-MS. Food tech example: a peanut peptide with a known fingerprint tells the analyst that peanut protein was present.
Blank sample
A sample with no food in it, run alongside real samples to catch contamination in the laboratory. Food tech example: a blank that gives a positive PCR result warns the laboratory that contamination has occurred.
Control
A sample with a known result, run with a batch of tests to show the test worked as it should. Food tech example: a positive control in an ELISA run shows that the test can still find the allergen.
Sampling plan
A written plan that says where, when, how much, and by whom a sample is taken, so the sample represents the food. Food tech example: a sampling plan for biscuits takes biscuits from the start, middle, and end of a run.
Not detected
A test result meaning the amount was below the limit of detection of that test, on that sample. Food tech example: "not detected" for egg protein in a sauce means the level was below the LOD, not that the sauce contains no egg at all.
Matrix
The food itself, with its fat, sugar, and other parts, which can hide a protein from a test or make a test read high. Food tech example: the chocolate matrix can make an ELISA read low for milk protein.
References
- Nielsen, S. S., Introduction to the Chemical Analysis of Foods, 1997.
- Taylor, S. L. and Hefle, S. L., Food Allergies and Intolerances, 2005.
- Jackson, L. S., Food Allergen Management, 2013.
- Food and Agriculture Organization, Food Allergies, 2021.
- Poms, R. E. and Anklam, E., Food allergen detection methods, 2004.