GIFSQ ID: CAL-0552
GIFSQ Tools : Food Safety : Version v1 : Technical review date: 2026-11-15
Completion of the live Sanitation Schedule Builder and Cleaning Verification Calculator (schedule plus RLU check, no single verification planner): plans what to verify, where, how often, with which method and limit, and scores the verification.
Educational calculator: this is a calculation aid for learning and planning. It is not a validated food safety process and must not be presented as one. Confirm any value against your accredited method and your own process validation before using it in production.
Inputs
Formula
Verification coverage % = sites verified / sites planned x 100. Pass rate % = sites passed / sites verified x 100. RLU verdict: at or below the pass limit is pass; above the pass limit and at or below the fail limit is caution; above the fail limit is fail (limits from the live Cleaning Verification Calculator worked test: pass 150, fail 300). Verification methods are from Food Quality Assurance, Ch. 4.10.8: microbiological swab tests, visual inspection of cleaned equipment and areas, and observing employees who carry out cleaning and sanitising. The written program must also state, per Ch. 4.10.1: each item to clean and sanitise, procedure, chemicals and concentrations, residue removal, tools, frequency, and the person responsible.
Variable definitions and units
Sites: count. RLU reading and limits: RLU. Coverage and pass rate: %.
Assumptions
Limits are set for the site and method in use. Verification is separate from routine monitoring: the program is monitored to check it is followed, and verified to check it is effective (book, Ch. 4.10.1).
Input validation
Sites planned greater than 0. Sites verified 0 to sites planned. Sites passed 0 to sites verified. RLU limits: pass limit greater than 0 and less than fail limit. RLU reading 0 or greater.
Worked example
Live Cleaning Verification Calculator worked test: 120 RLU with pass limit 150 and fail limit 300 gives pass. Illustrative plan score: 18 of 20 sites verified gives coverage 90.00%; 16 of 18 passed gives pass rate 88.89%.
Expected output
Coverage %, pass rate %, RLU verdict (pass, caution or fail), and the verification plan fields: site, method (swab, visual, observation), frequency, limit, person responsible.
Calculation limitations
RLU limits are method and surface specific; the 150 and 300 values are the live tool worked test, not a universal limit. A pass does not prove the absence of a hazard; it shows the verification check passed at that site and time.
Source
Food Quality Assurance: Principles and Practices, Ch. 4.10.1, 4.10.3, 4.10.8 and 4.10.9. Completes live Sanitation Schedule Builder and Cleaning Verification Calculator.