Protein Quiz
GIFSQ ID: ART-1443
Test your knowledge with this free 20-question Protein quiz from Food Analysis & Analytical Chemistry, part of…
What this quiz covers
Protein content on a food label is almost never measured directly. It is inferred, usually from nitrogen, and this quiz covers the methods that do the inferring and the traps they carry. The Kjeldahl method determines protein indirectly by measuring total nitrogen and multiplying by a nitrogen-to-protein factor: digestion, distillation and titration, in that order. Digestion uses catalysts such as copper or selenium salts with potassium sulfate to raise the boiling point of the acid, distillation uses strong alkali to convert ammonium ions to ammonia gas for collection, and a reagent blank corrects for nitrogen the reagents contribute. The Dumas combustion method burns the sample in oxygen and measures the released nitrogen gas: faster, automated, and free of concentrated acids and toxic catalysts, which is why laboratories moving to high throughput prefer it.
The factors matter as much as the methods. The general factor for most foods is 6.25, wheat and wheat flour use 5.70, and milk and dairy products use 6.38, because each protein source carries a different nitrogen fraction. Both methods share one known limitation: they also count non-protein nitrogen, urea and melamine included, as protein, which is why true protein in milk is measured after precipitating it with trichloroacetic acid. Casein is separated from whey proteins by acidifying milk to pH 4.6, the isoelectric point of casein, which precipitates it. The colorimetric methods each have their own chemistry: biuret forms a violet complex between copper(II) and peptide bonds in alkaline solution, Lowry adds reduction of the Folin-Ciocalteu reagent by tyrosine and tryptophan for higher sensitivity, Bradford works through Coomassie dye binding, and BCA is favored for extracts containing detergents. UV absorbance at 280 nm works because tryptophan and tyrosine absorb there, NIR instruments estimate protein in grains rapidly but only with a calibration built against Kjeldahl or Dumas reference data, and amino acid analysis needs complete acid hydrolysis, typically 6 M HCl, first.
Kjeldahl measures nitrogen, not protein
That one sentence explains the factors, the blank, the non-protein nitrogen trap, and the melamine frauds that made headlines: the method counts nitrogen atoms and trusts the factor to turn them into protein. When the factor is wrong for the food, or when nitrogen comes from something that is not protein at all, the label number is wrong even though the chemistry ran perfectly.
How to use this quiz
Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the methods, factors and chemistry a food analyst is expected to know by heart.
Choose how you want to play
A short note: protein
Kjeldahl and Dumas measure protein from total nitrogen. Kjeldahl digests the sample in concentrated sulfuric acid, turning organic nitrogen into ammonium, then alkali converts it to ammonia for distillation and titration. Dumas burns the sample in oxygen and measures the released nitrogen gas, faster, without acids or toxic catalysts. Both count non-protein nitrogen, urea and melamine included, as protein: the blind spot behind the 2008 melamine adulteration of milk.
The general factor is 6.25, assuming 16 percent nitrogen; wheat uses 5.70 and dairy 6.38, from the International Dairy Federation and ISO 8968. True protein is separated from non-protein nitrogen by trichloroacetic acid precipitation, and casein from whey by acidifying to pH 4.6, its isoelectric point. A reagent blank corrects for nitrogen from the reagents. Amino acid analysis needs complete acid hydrolysis first, in 6 M HCl at 110 C for 22 to 24 hours. Copper or selenium salts and potassium sulfate raise the boiling point and speed digestion.
Biuret turns violet as copper(II) binds peptide bonds in alkaline solution. Lowry adds Folin-Ciocalteu reagent, reduced by tyrosine and tryptophan, for higher sensitivity. Bradford binds Coomassie dye to protein, moving its absorption peak, mainly at basic amino acids. BCA tolerates detergents and denaturants that trouble Lowry or Bradford. UV absorbance at 280 nm works because tryptophan and tyrosine absorb. NIR estimates protein rapidly, but only against Kjeldahl or Dumas calibrations for that grain and instrument.
Practical takeaway: to report protein from nitrogen, use the right factor for the food.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: The Kjeldahl method determines protein in foods indirectly by measuring:
Correct answer: Total nitrogen, then multiplying by a nitrogen-to-protein factor
The Kjeldahl procedure digests the sample in concentrated sulfuric acid, converting organic nitrogen to ammonium; the analyst measures total nitrogen and multiplies by a nitrogen-to-protein factor. The result is indirect : nitrogen stands in for protein. AOAC Method 2001.11 (block digestion with copper catalyst) is a current Kjeldahl reference procedure for animal feed, forage, grain and oilseeds; other commodities carry their own Kjeldahl reference numbers.
Question 2: The Dumas combustion method determines protein by:
Correct answer: Burning the sample in oxygen and measuring the released nitrogen gas
The Dumas method burns the sample in oxygen at high temperature, converts all nitrogen to nitrogen gas, and measures it : typically by thermal conductivity : without any sulfuric-acid digestion. The nitrogen reading becomes protein via the same conversion factor. AOAC Method 990.03 (combustion) is a reference Dumas procedure for animal feed; food matrices use their commodity-specific Dumas references.
Question 3: True protein can be distinguished from non-protein nitrogen in milk by:
Correct answer: Precipitating true protein with trichloroacetic acid and measuring nitrogen in the precipitate
Trichloroacetic acid precipitates true protein while non-protein nitrogen (urea, free amino acids, creatine) stays in solution; measuring nitrogen in the precipitate gives true protein. AOAC Methods 991.20-991.22 use this precipitation for milk. The split matters because only the precipitated fraction is actual protein.
Question 4: Near-infrared (NIR) instruments estimate protein in grains rapidly, but the calibration must be:
Correct answer: Developed against Kjeldahl or Dumas reference data for the specific grain and instrument
Near-infrared instruments are secondary methods: their calibrations are built by regression against Kjeldahl or Dumas reference values, and a calibration is valid only for the grain type and instrument it was built on. Osborne's NIR spectroscopy texts stress this reference-dependence. Without that anchor, NIR numbers are uncalibrated guesses.
Question 5: The Lowry method combines biuret chemistry with:
Correct answer: Reduction of the Folin-Ciocalteu reagent by tyrosine and tryptophan for higher sensitivity
The Lowry assay runs the biuret copper reaction first, then adds Folin-Ciocalteu reagent, which tyrosine and tryptophan residues reduce to a blue chromophore : greatly increasing sensitivity over biuret alone. Lowry, Rosebrough, Farr and Randall published the method in 1951. The second step is what gives Lowry its low detection limit.
Question 6: The biuret method quantifies protein based on:
Correct answer: Formation of a violet complex between copper(II) and peptide bonds in alkaline solution
In alkaline solution, copper(II) coordinates with peptide-bond nitrogens to form a violet complex whose absorbance tracks protein concentration. Gornall, Bardawill and David described this biuret reaction in 1949. The chemistry requires peptide bonds, which is why it responds to proteins rather than free amino acids.
Question 7: Compared with Kjeldahl, the Dumas method is generally:
Correct answer: Faster, automated and avoids concentrated acids and toxic catalysts
Dumas instruments run unattended in minutes per sample and avoid the concentrated sulfuric acid and toxic catalysts (mercury, selenium) that Kjeldahl digestion needs. That speed and safety profile is why many labs have switched reference methods. Comparative studies consistently show equivalent nitrogen recovery with far shorter hands-on time.
Question 8: A known limitation shared by Kjeldahl and Dumas protein results is that they:
Correct answer: Also count non-protein nitrogen (e.g., urea, melamine) as protein
Both methods measure total nitrogen, so any non-protein nitrogen : urea, ammonia, and infamously melamine : is counted as protein. The 2008 melamine adulteration of milk exploited exactly this blind spot (FDA/EFSA investigations). Neither method can distinguish protein nitrogen from added nitrogen compounds.
Question 9: For wheat and wheat flour, the commonly used nitrogen-to-protein factor is:
Correct answer: 5.70
Wheat and wheat flour use the factor 5.70, reflecting wheat proteins' higher nitrogen content than the 16% assumed by the general 6.25 factor. Jones's 1941 factors and AOAC cereal methods carry this value. Using 6.25 for wheat would systematically overstate its protein.
Question 10: In Kjeldahl analysis, the distillation step uses strong alkali to:
Correct answer: Convert ammonium ions to ammonia gas for collection in the receiving flask
Strong alkali (sodium hydroxide) added before distillation converts ammonium ions in the digest to volatile ammonia gas, which is steam-distilled into the receiving flask for titration. AOAC 2001.11 specifies this conversion step. Without the alkali, the nitrogen stays trapped as ammonium in the digest.
Question 11: Amino acid analysis of a food protein requires prior:
Correct answer: Complete acid hydrolysis (typically 6 M HCl) to release free amino acids
Bound amino acids must be freed before chromatography, so the protein is hydrolyzed : conventionally in 6 M hydrochloric acid at 110 °C for about 22-24 hours. AOAC Method 994.12 is built on this hydrolysis. The harsh conditions break every peptide bond, releasing the free amino acids for analysis.
Question 12: For milk and dairy products, the Kjeldahl nitrogen-to-protein factor used is:
Correct answer: 6.38
Milk and dairy products use the factor 6.38, derived from the nitrogen content of milk proteins (about 15.7%). The International Dairy Federation and ISO 8968 specify 6.38 for dairy. Applying the general 6.25 factor would understate dairy protein.
Question 13: A reagent blank is run in Kjeldahl analysis to:
Correct answer: Correct for any nitrogen contributed by the reagents themselves
Reagents themselves can contribute traces of nitrogen, so a reagent blank : the full procedure run without sample : is measured and subtracted. This correction is written into Kjeldahl reference procedures. Skipping it folds reagent nitrogen into the protein result.
Question 14: Casein in milk is separated from whey proteins in the laboratory by:
Correct answer: Acidifying to pH 4.6, the isoelectric point of casein, which precipitates it
Casein precipitates at its isoelectric point, pH 4.6, while whey proteins remain soluble : the classic acid-precipitation split formalized in Rowland's fractionation and AOAC milk methods. Adjusting skim milk to pH 4.6 drops the casein out cleanly. The precipitate is the casein fraction; the serum holds the whey proteins.
Question 15: The three main steps of Kjeldahl analysis are:
Correct answer: Digestion, distillation and titration
Every Kjeldahl determination runs the same three stages: digestion of the sample in hot sulfuric acid, distillation of the liberated ammonia, and titration of the collected ammonia. AOAC 2001.11 is organized around these steps. Each stage has one job : convert, separate, then measure.
Question 16: The general nitrogen-to-protein conversion factor used for most foods is:
Correct answer: 6.25
The general conversion factor 6.25 assumes protein contains 16% nitrogen by mass, and it applies to most foods lacking a specific factor. Jones's 1941 review established this default. Commodity-specific factors (wheat 5.70, dairy 6.38) replace it only where the protein composition is well characterized.
Question 17: Measuring protein by UV absorbance at 280 nm works because:
Correct answer: Tryptophan and tyrosine residues absorb near 280 nm
Ultraviolet absorbance at 280 nm comes from the aromatic side chains of tryptophan and tyrosine : peptide bonds absorb much lower, near 210-220 nm. Protein chemistry texts use this distinction routinely. The 280 nm reading therefore tracks aromatic-residue content, not total peptide bonds.
Question 18: The BCA (bicinchoninic acid) assay is favored for food protein extracts containing detergents because it:
Correct answer: Tolerates many detergents and denaturants better than Lowry or Bradford
The bicinchoninic acid assay tolerates detergents and denaturants (SDS, urea) that interfere with Lowry or Bradford chemistry, while still needing a standard curve like any colorimetric assay. Smith and colleagues introduced the BCA assay in 1985. That robustness is why it dominates detergent-containing food protein extracts.
Question 19: The Bradford assay measures protein through:
Correct answer: Binding of Coomassie dye, shifting its absorption maximum, mainly with basic amino acids
The Bradford assay binds Coomassie Brilliant Blue G-250 to protein : mainly to basic residues such as arginine : shifting the dye's absorption maximum from brown to blue. Bradford published the method in 1976. The color change, read near 595 nm, is proportional to protein concentration.
Question 20: In Kjeldahl digestion, catalysts such as copper or selenium salts and potassium sulfate are added to:
Correct answer: Raise the boiling point of the acid and speed up digestion
Potassium sulfate raises the boiling point of the sulfuric acid so digestion runs hotter and faster, while copper or selenium salts catalyze the breakdown of organic matter. Both additions are standard in Kjeldahl reference procedures. Together they shorten digestion from hours to tens of minutes.