Other Food Analysis Topics – Part 2

GIFSQ ID: ART-0846

What this quiz covers

Food analysis is not one instrument or one test. It is a chain: separate the molecules, name the material, read the numbers, and then say what the numbers mean. This quiz walks that chain in twenty questions, starting with electrophoresis and ending with the plots that turn a table of results into a picture a reader can follow.

Electrophoresis comes first: SDS-PAGE separates proteins by size once SDS coats them with a uniform charge, DNA moves toward the anode because it carries a negative charge, and polyacrylamide gel handles both proteins and DNA. Pairing SDS-PAGE with gel filtration gives both subunit size and the number of subunits in a protein, which neither method gives on its own.

The middle of the quiz tests the abbreviations that fill a lab notebook and a packaging specification: PE, PVC and PAT among the plastics, and PCA, TFA, PSD and ELS among the data and particle methods. Maillard browning gets its own questions too, including the brown melanoidin end products and furosine as a marker of heat damage to lysine.

Concepts you will need

Keep three ideas apart: separation by size, separation by charge, and data reduction. SDS-PAGE is size. PCA, TFA and projection pursuit are ways of visualising many variables at once, not ways of separating molecules. If you sort each question into one of those three boxes before answering, the abbreviations stop blurring together.

How to use this quiz

You get 20 seconds per question and one attempt at each answer, so read the abbreviation or the method name first and name the idea it belongs to before you look at the options. A wrong answer here usually means two similar terms swapped places, so re-pair each abbreviation with its full form before retaking.

Other Food Analysis Topics – Part 2
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

Answer explanations

Worked through the quiz? Here is why each correct answer is correct: the concept behind it, in plain terms.

  1. On what basis do proteins separate in SDS-PAGE?
    1. Size (correct answer)
    2. Positively charged residue content
    3. Negatively charged residue content
    4. Both positive and negative residue content

    Correct answer: Size. In SDS-PAGE every protein is unfolded and coated with the same negative charge per unit mass, so charge differences are cancelled out and the only thing the gel can discriminate is size — the smaller the protein, the faster it threads through the pores. Positively or negatively charged residue content is what matters in native PAGE, not here; the basis of separation in SDS-PAGE is size.
  2. Which approach reveals both subunit molecular weight and the number of subunits?
    1. SDS-PAGE electrophoresis
    2. Gel filtration chromatography
    3. Isoelectric focusing
    4. Combining SDS-PAGE with gel filtration (correct answer)

    Correct answer: Combining SDS-PAGE with gel filtration. SDS-PAGE reveals the molecular weight of the subunits — each band's position gives a subunit's mass — while gel filtration of the intact native protein gives the total molecular weight of the whole complex. Dividing the total by the subunit weight reveals the number of subunits. Neither technique alone gives both numbers; only combining SDS-PAGE with gel filtration reveals both subunit molecular weight and the number of subunits.
  3. Which molecules is polyacrylamide gel usually used for?
    1. Proteins
    2. DNA
    3. Vitamins
    4. Both proteins and DNA (correct answer)

    Correct answer: Both proteins and DNA. Polyacrylamide gels are the workhorse matrix for both small proteins (SDS-PAGE) and small DNA fragments: their fine, uniform pores give the high resolution needed for short fragments and low-molecular-weight proteins, while agarose is reserved for larger DNA. So polyacrylamide gel is usually used for both proteins and DNA.
  4. Towards which electrode does DNA move in agarose gel electrophoresis?
    1. Cathode
    2. Anode (correct answer)
    3. It does not move
    4. None of these

    Correct answer: Anode. DNA is negatively charged along its phosphate backbone, so in an electric field it is attracted to the positive electrode — the anode. The cathode is the negative electrode and would repel it; in agarose gel electrophoresis DNA always moves towards the anode.
  5. Which statement about SDS polyacrylamide gel electrophoresis is correct?
    1. Proteins keep their biological activity after SDS-PAGE
    2. Proteins are solubilized but not denatured
    3. It separates proteins by charge
    4. It separates proteins by size (correct answer)

    Correct answer: It separates proteins by size. SDS-PAGE separates proteins by size: SDS denatures the proteins and coats them with a uniform negative charge per unit mass, cancelling out intrinsic charge differences, and the gel then sieves by size alone. That means the proteins lose their biological activity (they are denatured, not merely solubilized) and charge plays no part in the separation.
  6. In packaging plastics, what does the abbreviation PE mean?
    1. Polyethylene (correct answer)
    2. Polymethylene
    3. Polyoxymethylene
    4. Polyester

    Correct answer: Polyethylene. PE is the universal abbreviation for polyethylene, the most common food-packaging plastic, made by polymerizing ethylene into long chains. Polymethylene, polyoxymethylene and polyester are different materials with different names and abbreviations.
  7. The plastic PVC, used in food films and bottles — what is its full name?
    1. Polyvinyl chloride (correct answer)
    2. Poly vinyl chlorine
    3. Polyester vinyl chloride
    4. Polyvinyl carbonate

    Correct answer: Polyvinyl chloride. PVC is polyvinyl chloride — the polymer of vinyl chloride monomer, widely used in food films, cling film and bottles. 'Poly vinyl chlorine' is a garbled version of the name, and the other options invent carbonate or polyester combinations that do not exist.
  8. PAT is short for a polyester packaging resin — what is the correct full form?
    1. Polyalkylene terephthalate (correct answer)
    2. Polyalkylene teraphthalate
    3. Polyalkylene tetraphthalate
    4. Polyalkylene terephthalamide

    Correct answer: Polyalkylene terephthalate. PAT is the general family abbreviation for polyalkylene terephthalate — the polyester group that includes polyethylene terephthalate (PET), polybutylene terephthalate (PBT) and polypropylene terephthalate (PPT). The distractors are misspellings (teraphthalate, tetraphthalate) or a different chemistry (terephthalamide is a polyamide, not a polyester).
  9. What does PCA stand for?
    1. Protein Composition Analysis
    2. Purification and Concentration Assay
    3. Polar Compound Analysis
    4. Principal Component Analysis (correct answer)

    Correct answer: Principal Component Analysis. In multivariate data analysis, PCA stands for Principal Component Analysis — the technique that compresses many correlated variables into a few principal components capturing most of the variation. The other expansions are invented phrases.
  10. What does TFA stand for?
    1. Tertiary Factor Analysis
    2. Thermal Factor Analysis
    3. Total Factor Analysis
    4. Target Factor Analysis (correct answer)

    Correct answer: Target Factor Analysis. In chemometrics, TFA stands for Target Factor Analysis — a factor-analysis technique used to resolve overlapping signals and test candidate factors against experimental data. Tertiary factor analysis, thermal factor analysis and total factor analysis are not the established meaning.
  11. What does PSD stand for?
    1. Pore Size Determination
    2. Powder Size Distribution
    3. Particle Size Distribution (correct answer)
    4. Phase Separation Degree

    Correct answer: Particle Size Distribution. PSD stands for Particle Size Distribution — the description of how particle sizes are spread across a sample, a routine measurement for powders, emulsions and packaging materials. Pore size determination, powder size distribution and phase separation degree are not the standard expansion.
  12. What does ELS stand for?
    1. Elastic Light Scattering
    2. Emission Light Spectroscopy
    3. Electron Light Scattering
    4. Electrophoretic Light Scattering (correct answer)

    Correct answer: Electrophoretic Light Scattering. ELS stands for Electrophoretic Light Scattering — the light-scattering technique that measures how particles move in an electric field, used to determine zeta potential and surface charge. The elastic, emission and electron variants are not the standard term.
  13. Maillard browning is which type of browning?
    1. Both enzymatic and non-enzymatic
    2. Non-enzymatic (correct answer)
    3. Neither
    4. Enzymatic

    Correct answer: Non-enzymatic. Maillard browning is non-enzymatic browning: it is the purely chemical reaction between reducing sugars and amino groups, and it needs no enzyme at all. Enzymatic browning is a separate process driven by polyphenol oxidase — the two must not be confused.
  14. What are the final brown products of the Maillard reaction called?
    1. Melanoidins (correct answer)
    2. Carboxylic acids
    3. Melanin
    4. Peptides

    Correct answer: Melanoidins. The brown end products of the Maillard reaction are called melanoidins — the complex, high-molecular-weight brown pigments formed in the advanced stages of the reaction. Melanin is the dark pigment of skin and hair, and carboxylic acids and peptides are not the brown end products.
  15. Furosine is used to assess heat damage to which amino acid in foods?
    1. Tyrosine
    2. Phenylalanine
    3. Leucine
    4. Lysine (correct answer)

    Correct answer: Lysine. Furosine is formed from the Amadori product of lysine and glucose when a protein is acid-hydrolysed, so measuring furosine tells how much lysine has been blocked by early Maillard reactions. It is the standard chemical marker for heat damage to lysine — not to tyrosine, phenylalanine or leucine.
  16. Which of these are forms of electrophoresis?
    1. Disc gel
    2. Zone
    3. All of these (correct answer)
    4. Paper

    Correct answer: All of these. Electrophoresis comes in many formats: disc (discontinuous) gel electrophoresis, zone electrophoresis and paper electrophoresis are all genuine forms, alongside gel, capillary and isoelectric focusing. So all of these are forms of electrophoresis.
  17. What is analysed by electrophoresis?
    1. Fat
    2. None of these
    3. Carbohydrate
    4. Protein (correct answer)

    Correct answer: Protein. Electrophoresis is the standard analytical tool for proteins: serum protein analysis, SDS-PAGE, isoelectric focusing and native gels all resolve and characterize proteins. Fats and carbohydrates are not its routine analytes — protein is what is analysed by electrophoresis.
  18. Which of these visualises multivariate data?
    1. Evolving Factor Analysis
    2. Orthogonal Rotation
    3. Principal Component Analysis (correct answer)
    4. Target Factor Analysis

    Correct answer: Principal Component Analysis. Principal Component Analysis visualises multivariate data by compressing many correlated variables into two or three principal components that can be plotted, so patterns and clusters become visible. Evolving factor analysis and target factor analysis are resolution methods, and orthogonal rotation is a factor-alignment step — PCA is the visualization workhorse.
  19. Which of these is a data visualisation method?
    1. Evolving Factor Analysis
    2. Non-linear Mapping (correct answer)
    3. Target Factor Analysis
    4. Orthogonal Rotation

    Correct answer: Non-linear Mapping. Non-linear mapping is a data-visualisation method: it projects high-dimensional data points into two or three dimensions while preserving their relative distances, so clusters and structure can be seen at a glance. Factor-analysis and rotation methods are data-analysis tools, not visualization methods.
  20. Which of these is used to visualise multivariate data?
    1. Orthogonal Rotation
    2. Target Factor Analysis
    3. Evolving Factor Analysis
    4. Projection Pursuit (correct answer)

    Correct answer: Projection Pursuit. Projection pursuit is used to visualise multivariate data: it searches for the most 'interesting' low-dimensional projections of high-dimensional data so that structure such as clusters can be displayed. Orthogonal rotation and the target/evolving factor-analysis methods are factor techniques, not projection-based visualization.