Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

Food Analysis Methods Quiz

GIFSQ ID: ART-1013

What this quiz covers

Food analysis runs on separation and measurement, and this quiz opens inside the chromatograph. The mobile phase can be liquid or gas, the stationary phase supported on a solid can be solid or liquid, and a chromatogram plots time against concentration, with peak positions telling you which components are present. Raising the flow rate cuts longitudinal diffusion broadening, which is the B term of the van Deemter relationship, though faster flow also widens peaks through the mass transfer term, so the gain is partial rather than free. HPLC and UPLC differ mainly in particle size: UPLC uses sub-2-micron packings at very high pressure.

The techniques and instruments fill the middle of the set. Ninhydrin sprayed on paper to detect amino acids is paper chromatography, gradient, stepwise and zone elution all run on a column, TLC is inexpensive, portable and reliable, and the injector, column and detector are all system components. Solvent reservoirs, injection device, data acquisition and detector all belong to the liquid chromatography instrument, and DSC stands for Differential Scanning Calorimetry, which tracks heat flow against a reference as temperature is scanned.

Labels, indicators, and two pH anchors

Apparent density of cereal grains is measured with the single-kernel characterization system, iodine tracks starch conversion by its blue complex, coffee is commonly adulterated with chicory, potassium nitrite is E249 and karaya gum is E416. The two pH anchors close the set: 1 M NaOH is pH 14 and 1 M HCl is pH 0, mirror images of strong base and strong acid.

How to use this quiz

Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the correct choice in plain words, so a miss becomes a fact you keep. The ‘all of these’ options are often right here, but only when every item listed truly belongs, so check each one.

Food Analysis Methods Quiz
Uncategorized

Choose how you want to play

Sound effects
πŸ”ˆ Volume
Show explanations
πŸ”Š Auto-read every question
Reading speed

Answer explanations

Worked through the quiz? Here is why each correct answer is correct: the concept behind it, in plain terms.

  1. When a chromatogram is used as the detector, the graph is plotted between time and what?
    Correct answer: Concentration. When a chromatogram is used as the detector output, the graph is plotted between time and concentration. Time on the axis gives retention time, which identifies each component, and the detector response at each moment reflects the concentration of whatever is eluting then.
  2. Why would you raise the flow rate in chromatography?
    Correct answer: To reduce longitudinal diffusion broadening. Raising the flow rate reduces longitudinal diffusion broadening. In the van Deemter relationship the longitudinal diffusion term falls as flow velocity rises, because analytes spend less time diffusing along the column. Note: faster flow also widens peaks through the mass transfer term, so the benefit is partial.
  3. What is the main difference between HPLC and UPLC?
    Correct answer: UPLC uses smaller stationary-phase particles. The main difference is that UPLC uses smaller stationary-phase particles , sub-2-micron packings run at very high pressure, versus the larger particles of conventional HPLC. Both can run reverse or normal phase, use the same kinds of mobile phases, and use the same detector types.
  4. When the stationary phase is supported on a solid, what can it be?
    Correct answer: Solid or liquid. When the stationary phase is supported on a solid, it can be solid or liquid , a liquid stationary phase coated onto a solid support gives partition chromatography, while the bare solid surface gives adsorption chromatography. It is not restricted to one physical state.
  5. Spraying ninhydrin on paper to detect amino acids is an example of which chromatography?
    Correct answer: Paper chromatography. Spraying ninhydrin on paper to detect amino acids is the classic paper-chromatography experiment , ninhydrin reacts with amino acids to give the characteristic purple spots after separation. Column, thin-layer and liquid chromatography use different supports and detection setups for this analysis.
  6. What do peak positions on a chromatogram's time axis tell you?
    Correct answer: The components present. Peak positions on the chromatogram's time axis tell you the components present , each compound has a characteristic retention time under given conditions, so the position identifies what it is. How much is present comes from peak area or height, not position.
  7. What can the mobile phase in chromatography be?
    Correct answer: Liquid or gas. The mobile phase in chromatography can be liquid or gas , liquid in liquid chromatography and gas in gas chromatography. It must flow to carry analytes through the system, so a solid can never serve as the mobile phase.
  8. Which of these run on a chromatography column?
    Correct answer: All of these. All of these run on a chromatography column , gradient elution, stepwise elution and zone chromatography are all elution modes performed on a packed or coated column. They differ in how the mobile phase composition changes, not in where the separation happens.
  9. Which of these are true of TLC?
    Correct answer: All of these. All of these are true of TLC , it is inexpensive, portable and reliable, which is why it remains a workhorse for quick qualitative screening. No special instrumentation is needed beyond the coated plate and a developing chamber.
  10. Which of these are chromatography system components?
    Correct answer: All of these. All of these are chromatography system components , the injector introduces the sample, the column performs the separation, and the detector senses the eluting analytes. A working chromatograph needs every one of them.
  11. Which of these are parts of a liquid chromatography instrument?
    Correct answer: All of these. All of these are parts of a liquid chromatography instrument , the solvent reservoirs hold the mobile phase, the injection device introduces the sample, and the column carries out the separation. Each is essential to the flow path.
  12. Which of these belong to the detection and control side of a liquid chromatography instrument?
    Correct answer: Data acquisition and detector. The detection and control side is everything that senses the separation and manages the run: the detector converts eluting analytes into an electrical signal, and the data acquisition system records and processes that signal into the chromatogram.
  13. What does the analytical technique DSC stand for?
    Correct answer: Differential Scanning Calorimetry. DSC stands for Differential Scanning Calorimetry , the technique that measures heat flow into or out of a sample versus a reference as temperature is scanned, revealing melting, crystallization and denaturation transitions.
  14. What is apparent density of cereal grains measured with?
    Correct answer: Single-kernel characterization system. Apparent density of cereal grains is measured with the single-kernel characterization system, the only listed instrument that characterizes grain kernels themselves, measuring kernel weight, diameter, hardness and moisture.
  15. What indicator is used to track starch conversion?
    Correct answer: Iodine. Iodine is the indicator used to track starch conversion , it forms a deep blue complex with intact starch, and the fading of that color shows starch being broken down. Alpha-amylase, beta-amylase and diastase are the enzymes doing the conversion, not the indicator revealing it.
  16. What is coffee commonly adulterated with?
    Correct answer: Chicory. Coffee is commonly adulterated with chicory , roasted chicory root resembles coffee in color and flavor, which is why it has been the classic coffee extender and adulterant. Sawdust and ghee are not typical coffee adulterants.
  17. Potassium nitrite is listed under which E-number on food packaging?
    Correct answer: E249. Potassium nitrite is listed as E249 on food packaging. In the nitrite-nitrate series, E249 is potassium nitrite, E250 is sodium nitrite, E251 is sodium nitrate and E252 is potassium nitrate.
  18. If karaya gum appears on a label, which E-number identifies it?
    Correct answer: E416. Karaya gum appears as E416 on labels. In the gum series, E413 is tragacanth, E414 is acacia, E415 is xanthan and E416 is karaya.
  19. What is the pH of 1 M NaOH?
    Correct answer: 14. The pH of 1 M NaOH is 14 , a 1 molar hydroxide solution gives a hydroxide concentration of 1 M, so pOH is 0 and pH is 14. It is a strongly basic solution, far from neutral 7.
  20. What is the pH of 1 M HCl?
    Correct answer: 0. The pH of 1 M HCl is 0 , a 1 molar strong acid gives a hydrogen ion concentration of 1 M, so pH is 0. It is a strongly acidic solution, the mirror image of 1 M NaOH.