Energy Audits Quiz
GIFSQ ID: ART-2071
Test your knowledge with this free 20-question Energy Audits quiz from Utilities & Energy Management in Food Plants…
What this quiz covers
An energy audit finds where a food plant’s energy actually goes and which savings are worth chasing, and this quiz covers the audit from the first walk-through to the final verification. It starts with the levels: a preliminary walk-through audit is a quick scan management uses to decide whether a detailed study is worthwhile, a Level 1 audit primarily delivers a quick list of low or no-cost measures and targets for deeper study, a Level 2 detailed audit adds measured data, energy balances, and costed recommendations with paybacks, and an investment-grade Level 3 audit is distinguished by engineering-grade accuracy suitable for financing decisions. The first step of any energy audit is usually collecting 12 or more months of utility bills and production data, because without that history an audit is guessing, and interviewing operators is valuable because they know the actual operating practices that data alone may miss.
The quiz then covers the tools and the numbers. A Sankey diagram visualizes energy flows with arrow widths proportional to quantities, showing at a glance where the energy goes. Analyzing the plant’s electrical load profile, demand against time, helps identify peak-demand causes and off-hours waste. An energy baseline is established so future savings can be measured against normalized past performance, and comparing energy use per tonne across months with different output levels requires normalizing for production volume and weather where relevant. Specific energy consumption is expressed as energy per unit of production, for example kilowatt-hours per tonne, and benchmarking a food plant means comparing its specific energy use against similar plants or best practice. Simple payback is the initial investment divided by annual savings, while net present value accounts for the time value of money over the project life, which simple payback ignores. Audit recommendations are usually prioritized by payback period and savings magnitude, so the biggest saving with the fastest return goes first.
The audit finds the saving, only action captures it
That is the lesson of the final question: the most common reason audit recommendations fail to deliver savings is that the measures are never implemented or not maintained. The typical no-cost and low-cost findings in food plants, fixing compressed-air leaks, switching off idle equipment, and optimizing setpoints, cost nothing to fix and save immediately, which is why they top every walk-through list. The boiler example in the quiz shows the diagnostic habit: a boiler running at 75 percent efficiency with 12 percent oxygen in the flue gas most likely suffers from excessive excess air, carrying heat up the stack. The affinity laws explain why variable-speed drives save so much on centrifugal pumps: pump power varies with the cube of pump speed, so halving the speed cuts power to one-eighth. And measurement and verification after a retrofit, for example under IPMVP, confirms the savings actually achieved, adjusted for changing conditions, because without it claimed savings are just estimates.
How to use this quiz
Take the 20 questions in order, then read the answer explanations below the quiz. Each explanation names the correct answer and the reason behind it in plain words. If you work in a food plant, the load-profile and compressed-air questions are the ones to take back to your own site: peaks and leaks are where the money hides, and both are visible without any new equipment.
Choose how you want to play
A short note: energy audits
An energy audit systematically examines how a facility uses energy, to find waste and savings worth paying for, under ISO 50002.
Audits come in three depths. A Level 1 walk-through is a quick scan listing cheap fixes and targets for deeper study. Level 2 adds measurements, an energy balance, and priced recommendations. A Level 3 investment-grade audit adds accuracy a lender can rely on for financing.
Every audit starts with a year or more of utility bills and production records. The team then walks the site, talks to operators, and measures the big uses. A Sankey picture shows where energy goes, wider arrows for bigger flows, and a load profile exposes peaks and off-hours waste.
Specific energy use is energy per tonne of product; benchmarking compares it with similar plants. Simple payback divides money spent up front by money saved each year; net present value discounts future savings to what they are worth today. A variable-speed drive saves because power falls steeply as speed falls; halving speed cuts power to about an eighth. The most common no-cost findings are air leaks fixed, idle kit switched off, and setpoints tuned.
After a retrofit, measurement and verification under IPMVP checks what was truly saved, allowing for weather and output. Recommendations rank by payback and savings size, and most fail because measures are never implemented or maintained. Bring a year of bills and production records to the audit, and track the baseline so claimed savings can be proved.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: A preliminary (walk-through) audit is most appropriate when:
Correct answer: Management wants a quick scan to decide whether a detailed study is worthwhile
A walk-through audit is a quick scan, not a commitment. Management uses it to decide whether a deeper study is worth paying for.
Question 2: An audit finds the boiler running at 75% efficiency with 12% O2 in the flue gas. The most likely cause is:
Correct answer: Excessive excess air
Twelve percent oxygen in the flue gas means far too much excess air is going up the stack, carrying heat with it. That wasted heat shows up as poor boiler efficiency.
Question 3: A Sankey diagram in an energy audit is used to:
Correct answer: Visualize energy flows, with arrow widths proportional to quantities
A Sankey diagram draws energy flows as arrows whose widths are proportional to their quantities. The picture shows at a glance where the energy actually goes.
Question 4: Unlike simple payback, net present value (NPV) accounts for:
Correct answer: The time value of money over the project life
Net present value discounts future savings to today's money, which is exactly the time value of money over the project life. Simple payback ignores when the savings arrive.
Question 5: An energy baseline is established so that:
Correct answer: Future savings can be measured against normalized past performance
Without a normalized baseline of past performance, there is nothing to measure future savings against. The baseline is the ruler every later claim uses.
Question 6: Analyzing the plant's electrical load profile (demand vs time) helps identify:
Correct answer: Peak-demand causes and off-hours waste
Plotting demand against time exposes when peaks happen and what is running when nothing is being made. Peaks and off-hours waste are where the money hides.
Question 7: During an audit, interviewing operators is valuable because:
Correct answer: They know actual operating practices that data alone may miss
Operators run the plant as it really is, not as the drawings say. Interviewing them surfaces the operating practices that data alone will miss.
Question 8: Simple payback period is calculated as:
Correct answer: Initial investment divided by annual savings
Simple payback is the upfront investment divided by the annual saving. It answers one question: how many years until the money comes back.
Question 9: Typical no-cost/low-cost audit findings in food plants include:
Correct answer: Fixing compressed-air leaks, switching off idle equipment, optimizing setpoints
Compressed-air leaks, idle equipment left running, and setpoints left high cost nothing to fix and save immediately. That is why they top every walk-through list.
Question 10: The first step of any energy audit is usually:
Correct answer: Collecting 12+ months of utility bills and production data
Twelve or more months of utility bills and production data show the real pattern of use. Without that history, an audit is guessing.
Question 11: An investment-grade (Level 3) audit is distinguished by:
Correct answer: Engineering-grade accuracy suitable for financing decisions
An investment-grade audit delivers engineering-accuracy numbers that a lender can rely on. That accuracy is what separates Level 3 from the screening levels.
Question 12: A Level 1 (walk-through) energy audit primarily delivers:
Correct answer: A quick list of low/no-cost measures and targets for deeper study
A Level 1 audit screens the plant quickly and lists the low- and no-cost measures, plus targets for deeper study. Detailed engineering comes at Level 2.
Question 13: An energy audit proposes a variable-speed drive on a centrifugal chilled-water pump. Savings estimates rely on the affinity laws, which state that pump power varies with
Correct answer: the cube of the pump speed
The affinity laws state that pump power varies with the cube of pump speed. Halving the speed cuts the power to one-eighth : which is why variable-speed drives save so much.
Question 14: Specific energy consumption (SEC) is expressed as:
Correct answer: Energy per unit of production, e.g., kWh per tonne
Specific energy consumption divides total energy by total production, for example kilowatt-hours per tonne. That ratio is what lets plants compare themselves fairly.
Question 15: Energy benchmarking a food plant means:
Correct answer: Comparing its specific energy use against similar plants or best practice
Benchmarking compares a plant's specific energy use against similar plants or best practice. The gap shows how much improvement is realistic.
Question 16: Measurement and verification (M&V, e.g., IPMVP) after a retrofit is done to:
Correct answer: Confirm the savings actually achieved, adjusted for changing conditions
Measurement and verification confirms the savings actually achieved, adjusting for weather and production changes. Without M&V, claimed savings are just estimates.
Question 17: A Level 2 (detailed) energy audit adds what beyond Level 1?
Correct answer: Measured data, energy balances, and costed recommendations with paybacks
A Level 2 audit adds measured data, energy balances, and costed recommendations with paybacks. It turns the Level 1 shortlist into funded projects.
Question 18: Audit recommendations are usually prioritized by:
Correct answer: Payback period and savings magnitude
Recommendations are prioritized by payback period and savings magnitude. The biggest saving with the fastest return goes first.
Question 19: Comparing energy use per tonne of product across months with different output levels requires:
Correct answer: Normalizing for production volume (and weather, if relevant)
Monthly energy per tonne is meaningless unless production volume is normalized : and weather too, where it matters. Normalizing makes the months comparable.
Question 20: The most common reason audit recommendations fail to deliver savings is:
Correct answer: Measures are never implemented or not maintained
Most audit recommendations fail because the measures are never implemented or never maintained. The audit finds the saving; only action captures it.