What this quiz covers
Cp is one number that answers a plain question: does the process fit inside what the customer allows. The formula is Cp = (USL – LSL) / 6σ, the specification width divided by six process standard deviations. The numerator is the tolerance the customer allows; the denominator is the natural spread of a stable process, about 99.73% of a normal process output sitting inside plus or minus three sigma. Cp = 1.0 means the process just fits the tolerance, with no margin at all for drift. Cp = 1.33 means the 6σ spread takes up about 75% of the specification width, leaving a 25% cushion, and that is the widely used minimum benchmark in many industries. Cp = 2.0 means the specification is twice as wide as the process spread, the classic six-sigma level of potential capability.
The second half of the set is about what Cp cannot do, and those limits matter more than the arithmetic. Cp is dimensionless because the units cancel in the ratio, so it can be compared across different characteristics, but it says nothing about where the process mean sits. A process can show a healthy Cp while running off centre and making out-of-spec product, which is why Cpk, which accounts for centring, is needed alongside it. Cp is meaningful only when the process is stable and the data are close to normal, and it cannot be calculated for one-sided specifications, where only a maximum or a minimum exists: those use the one-sided indices Cpu or Cpl instead. When Cp falls below 1, the honest responses are to reduce variation or to reassess the specification through a legitimate engineering change, never to widen it on paper. Reducing variation is the preferred route, because a tighter process produces less scrap and rework. The worked example in the set makes the arithmetic concrete: with USL 110, LSL 90 and sigma 2, Cp = 20 / 12, about 1.67.
Cp measures potential, not performance
The word potential is the key to the whole index. Cp shows what the process could achieve if it were perfectly centred, because the formula compares spread to tolerance without any term for the mean. That is why Cp is most informative when the process is well centred, and why a supplier agreement asking for Cp of 1.33 or better is really asking for evidence, with data, that the supplier spread fits comfortably inside the customer specification, with margin to spare.
How to use this quiz
Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the formulas, benchmarks and limits a quality engineer is expected to know by heart.
Choose how you want to play
A short note: Cp, the process capability index
Cp, the process capability index, measures potential capability: how the spread of a stable process compares with the width of the specification. Cp equals (USL minus LSL) divided by 6 sigma, where USL and LSL are the upper and lower specification limits and sigma is the process standard deviation. The index has no units, because the units cancel.
Cp is called potential because it ignores where the process mean sits. A Cp of 1.0 means the 6 sigma spread exactly fills the specification width. A Cp of 1.33 is a common benchmark for a capable process, with the spread taking about three quarters of the width. A Cp of 2.0 means six-sigma potential. Below 1, the spread is wider than the specification, so some out-of-spec product is unavoidable even when the process is centred.
Cp only means something for a stable process with roughly normal data. It cannot be used with one-sided specifications, where only an upper or a lower limit exists. It also says nothing about centring: an off-centre process can still show a good Cp while producing defects, so Cp must be read with Cpk. The usual fix for low Cp is to reduce variation; a spec that no process can meet should be reassessed instead.
Remember: check that the process is stable first, then read Cp together with Cpk, never Cp alone.
Questions and answers
Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the questions and answers below. Match each answer by its wording.
Question 1: The formula for Cp is:
Correct answer: (USL − LSL) / 6σ
Process capability Cp is the ratio of what the customer allows to what the process naturally produces: Cp = (USL − LSL) / 6σ. The numerator is the specification width; the denominator is six process standard deviations, the natural spread of a stable process.
Question 2: Cp = 1.0 means:
Correct answer: The 6-sigma process spread exactly equals the specification width
Cp = 1.0 means the specification width exactly equals the 6σ natural spread of the process : the process just fits the tolerance, with no margin for any shift. In practice this is the bare minimum, since any drift produces defects.
Question 3: Cp improves when:
Correct answer: Process standard deviation decreases
Cp = (USL − LSL) / 6σ, so with the specification fixed, Cp rises only when the denominator shrinks : that is, when the process standard deviation decreases. Tightening the specification lowers Cp; sample size does not enter the formula at all.
Question 4: Cp is dimensionless because:
Correct answer: Both numerator and denominator are in the same measurement units, which cancel
USL and LSL are measured in the same units as the data (millimetres, grams, and so on), and σ is in those units too, so the units cancel in the ratio. Cp is therefore a pure number, comparable across different characteristics and units.
Question 5: Cp cannot be used with:
Correct answer: One-sided specifications (only USL or only LSL)
Cp needs a specification width (USL − LSL), so it cannot be calculated when only one limit exists : for example a maximum contaminant level with no minimum. One-sided specifications use the one-sided indices Cpu or Cpl instead.
Question 6: Cp values are meaningful only if:
Correct answer: The process is stable and data are approximately normal
Cp is a ratio of widths that assumes the process is in statistical control and that the data are approximately normally distributed, since the 6σ spread represents ±3σ around the mean. For an unstable or badly non-normal process, the computed Cp misrepresents actual capability.
Question 7: If Cp < 1, the appropriate response is to:
Correct answer: Reduce variation or legitimately reassess the spec, the process cannot fit
Cp below 1 means the process's natural 6σ spread is wider than the specification : nonconforming product is inevitable. The honest responses are to reduce variation, or to reassess the specification through a legitimate engineering change : never to widen it arbitrarily or ignore the result.
Question 8: Cp = 2.0 describes:
Correct answer: Six-sigma potential, the spec is twice as wide as the 6σ spread
Cp = 2.0 means the specification width is twice the 6σ process spread : the classic six-sigma level of potential capability. The process could tolerate substantial shift before producing defects, provided it is well centred.
Question 9: Cp compares:
Correct answer: Specification width to process spread
Cp compares the width of the specification (what is allowed) with the natural spread of the process (what the process does). It is a ratio of tolerance to variation, not a comparison of two processes.
Question 10: Increasing Cp by reducing process variation is generally:
Correct answer: The preferred improvement route, a tighter, more consistent process
Reducing process variation is the preferred way to improve Cp, because a tighter, more consistent process produces less scrap and rework and is more robust to drift. Widening the specification to raise Cp without improving the process changes the paperwork, not the product.
Question 11: A process with Cp = 1.33 has:
Correct answer: Its 6σ spread occupying 75% of the spec width, a common adequacy benchmark
Cp = 1.33 means the 6σ spread occupies 1/1.33, about 75%, of the specification width, leaving a 25% cushion. This is the widely used minimum benchmark in many industries for a process considered adequately capable.
Question 12: Using Cp alone to judge a process risks:
Correct answer: Approving an off-centre process that makes out-of-spec product
Cp says nothing about where the process mean sits, so a process can show a healthy Cp while running off-centre and producing out-of-spec product. That is why Cpk : which accounts for centring : is needed alongside Cp.
Question 13: The '6σ' in Cp's denominator represents:
Correct answer: The natural spread containing ~99.73% of a normal process's output
For a normal distribution, ±3σ around the mean contains about 99.73% of output. The 6σ denominator is that full natural spread : what a stable process produces on its own.
Question 14: What does Cp measure?
Correct answer: The potential capability, how the process spread compares to the specification width
Cp measures potential capability: how the process's natural spread compares with the specification width, assuming the process were perfectly centred. 'Potential' is the key word : Cp does not report where the process actually sits.
Question 15: In a supplier quality agreement, requiring Cp ≥ 1.33 means the supplier must:
Correct answer: Demonstrate their process spread fits well within your spec
A Cp ≥ 1.33 clause obliges the supplier to demonstrate, with data, that their process variation fits comfortably inside the customer's specification width : the 6σ spread occupying roughly three-quarters of the tolerance, leaving margin.
Question 16: Cp is most informative when:
Correct answer: The process is well centred between the spec limits
Cp is most informative when the process is well centred between the specification limits, because then the potential it measures is close to what the process actually achieves. Off-centre, Cp overstates real performance and Cpk tells the truer story.
Question 17: A limitation of Cp is that it:
Correct answer: Ignores process centring, a shifted process can show good Cp while making defects
Cp's formula contains no term for the process mean, so it ignores centring entirely: a badly shifted process can still report good Cp while making defects. Always pair Cp with a centring measure such as Cpk.
Question 18: If USL = 110, LSL = 90 and σ = 2, Cp equals:
Correct answer: 1.67
Cp = (110 − 90) / (6 × 2) = 20 / 12 ≈ 1.67. The specification is 20 units wide and the 6σ process spread is 12 units, so the process spread occupies about 60% of the tolerance.
Question 19: Why is Cp called 'potential' capability?
Correct answer: It shows what the process could achieve if perfectly centred
Cp shows what the process could achieve : its potential : because the formula compares spread to tolerance without accounting for the mean's position. Only if the process is perfectly centred is that potential actually realised.
Question 20: Cp does not account for:
Correct answer: Where the process mean sits relative to target
The Cp formula uses only the specification limits and the standard deviation; the process mean appears nowhere in it. Where the mean sits relative to target : the centring : is invisible to Cp, which is why Cpk exists.