Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

Pulsed Electric Field – Part 2

GIFSQ ID: ART-0817

What this quiz covers

Pulsed electric field treatment kills microbes with short bursts of electricity instead of heat, and this quiz works through the settings that decide how well it works. Shorter pulses cost less to run, and more vegetative cells are killed when the field is stronger, the pulses are more numerous, and each pulse lasts longer. The pulses can be monopolar or bipolar, and they can take sinusoidal, square or rectangular waveforms.

The waveform ranking is the heart of this quiz. The oscillatory waveform is the least energy-efficient for killing microbes, while the square wave is the most energy-efficient. Bipolar pulses kill microorganisms more effectively than monopolar ones. Higher ionic strength raises a product’s electrical conductivity, but as conductivity rises, microbial inactivation falls, so salty foods are harder to treat. Treatment chambers are arranged coaxial or co-field, with an insulator separating the electrodes of a co-field chamber, and the product only warms to about 30°C.

Where PEF stops working

PEF is limited to liquid foods of low conductivity, and bubbles in the food cause non-uniform treatment and safety problems. Vegetative cells in the logarithmic growth phase are the most sensitive, while bacterial spores and yeast ascospores resist treatment. Enzymes resist PEF more than microorganisms do, and enzyme inactivation depends on field strength, the active site, the suspension medium, pulse number, duration and width, total treatment time, and enzyme structure.

How to use this quiz

Keep two rankings in your head before you start: square wave at the efficient end and oscillatory at the wasteful end, and bipolar beating monopolar. Then remember the conductivity paradox: more ions mean higher conductivity but weaker killing. After you finish, read the explanations below the player: each one states the correct answer and the reason in plain words, so a wrong answer becomes a fact you can carry into the next lab session or exam.

Pulsed Electric Field – Part 2
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

Note: the player shuffles the questions and the answer options on every attempt, so the numbers in the player will not match the numbers in the explanations below. Match each answer by its wording.

Answer explanations

Worked through the quiz? Here is why each correct answer is correct: the concept behind it, in plain terms.

  1. Which PEF option costs less to run?
    1. Higher field strength
    2. Shorter pulses (correct answer)
    3. Both of these
    4. Neither

    Correct answer: Shorter pulses: Shorter pulses use less energy per treatment, so they cost less to run than higher field strength.
  2. Under which conditions does PEF kill more vegetative cells?
    1. Higher electric field intensities
    2. Higher number of pulses
    3. Larger duration of pulses
    4. All of these (correct answer)

    Correct answer: All of these: More vegetative cells are killed with higher electric field intensities, a higher number of pulses, and longer pulses.
  3. What types can PEF electric-field pulses be?
    1. Monopolar
    2. Bipolar
    3. Both of these (correct answer)
    4. Neither

    Correct answer: Both of these: PEF electric-field pulses can be monopolar or bipolar.
  4. PEF electric pulses take which waveforms?
    1. Sinusoidal
    2. Square
    3. Rectangular
    4. All of these (correct answer)

    Correct answer: All of these: PEF pulses can take sinusoidal, square or rectangular waveforms.
  5. Which PEF waveform is the least energy-efficient for killing microbes?
    1. Oscillatory (correct answer)
    2. Square wave
    3. Bipolar
    4. Exponential decaying

    Correct answer: Oscillatory: The oscillatory waveform is the least energy-efficient for killing microbes, since much of its energy is wasted in ringing.
  6. Which PEF waveform is the most energy-efficient for killing microbes?
    1. Square wave (correct answer)
    2. Bipolar
    3. Exponential decaying
    4. All of these

    Correct answer: Square wave: The square wave is the most energy-efficient, since it holds the field at full strength for the whole pulse.
  7. Which pulses kill microorganisms more effectively in PEF?
    1. Monopolar
    2. Bipolar (correct answer)
    3. Both are equal
    4. None of these

    Correct answer: Bipolar: Bipolar pulses kill microorganisms more effectively than monopolar pulses, since the field reversal stresses the cell membrane twice.
  8. How does higher ionic strength affect a product’s electrical conductivity?
    1. It increases (correct answer)
    2. It decreases
    3. It stays the same
    4. None of these

    Correct answer: It increases: Higher ionic strength means more ions available to carry charge, so electrical conductivity increases.
  9. What happens to PEF microbial inactivation as food conductivity rises?
    1. Increases
    2. Decreases (correct answer)
    3. Does not change
    4. None of these

    Correct answer: Decreases: As food conductivity rises, more of the pulse energy is lost as current through the food, so microbial inactivation decreases.
  10. How are PEF treatment chambers arranged?
    1. Coaxial
    2. Co-field
    3. Both of these (correct answer)
    4. Neither

    Correct answer: Both of these: PEF treatment chambers are arranged in coaxial or co-field configurations.
  11. What separates the electrodes of a co-field chamber in PEF processing?
    1. Insulator (correct answer)
    2. Capacitor
    3. Resistor
    4. None of these

    Correct answer: Insulator: An insulator separates the electrodes of a co-field chamber, keeping the field across the treatment gap.
  12. How hot does the product get during PEF treatment?
    1. 30°C (correct answer)
    2. 70°C
    3. 80°C
    4. 90°C

    Correct answer: 30°C: The product only warms to about 30°C during PEF treatment, which is why PEF counts as a non-thermal process.
  13. PEF is limited to which foods?
    1. Liquid foods
    2. Low-conductivity foods
    3. Both of these (correct answer)
    4. Neither

    Correct answer: Both of these: PEF is limited to liquid foods of low conductivity, since solids cannot flow through the chamber and conductive foods short the field.
  14. What do bubbles in food lead to during PEF?
    1. Non-uniform treatment
    2. Safety problems
    3. Both of these (correct answer)
    4. Higher inactivation

    Correct answer: Both of these: Bubbles in food lead to non-uniform treatment, since the field concentrates around them, and to safety problems from arcing.
  15. In which growth phase are vegetative cells most sensitive to PEF?
    1. Logarithmic (correct answer)
    2. Stationary
    3. Both of these
    4. Neither

    Correct answer: Logarithmic: Vegetative cells in the logarithmic growth phase are most sensitive to PEF, since they are actively dividing with thinner walls.
  16. Which microbes are more resistant to PEF processing?
    1. Bacterial spores
    2. Yeast ascospores
    3. Both of these (correct answer)
    4. Vegetative cells

    Correct answer: Both of these: Bacterial spores and yeast ascospores are both more resistant to PEF than vegetative cells.
  17. What inactivates microorganisms more effectively in PEF processing?
    1. Higher electric field strength
    2. Longer treatment time
    3. Both of these (correct answer)
    4. Neither

    Correct answer: Both of these: Both higher electric field strength and longer treatment time inactivate microorganisms more effectively.
  18. Which resists PEF treatment more?
    1. Enzymes (correct answer)
    2. Microorganisms
    3. Both are equally sensitive
    4. None of these

    Correct answer: Enzymes: Enzymes resist PEF treatment more than microorganisms do, so PEF-treated foods may still need enzyme control.
  19. Which factors affect enzyme inactivation during PEF?
    1. Electric field strength, the active site, and the suspension medium
    2. Pulse number, duration, and width
    3. Total treatment time and enzyme structure
    4. All of these (correct answer)

    Correct answer: All of these: Enzyme inactivation during PEF depends on field strength, the active site and the suspension medium, on pulse number, duration and width, and on total treatment time and enzyme structure.
  20. Which of these are true of PEF technology?
    1. Kills vegetative cells
    2. No toxicity
    3. Shorter treatment time
    4. All of these (correct answer)

    Correct answer: All of these: PEF kills vegetative cells, leaves no toxic residues, and works in a shorter treatment time than heat pasteurization.