Login Register

Access the GIFSQ Portal

Select your user type to log in or register a new account.

Student Portal

Access your food safety courses and exams.

Instructor Portal

Manage courses, view student submissions, and grade quizzes.

Company Portal

Manage corporate setup, view employee logs, and access QA services.

Other Food Analysis Topics – Part 5

GIFSQ ID: ART-0849

Questions on food analysis topics that didn't fit the main analysis quizzes.

What this quiz covers

This quiz finishes the food analysis set, and it rewards the same habit the lab rewards: keep the scale, the method and the instrument straight. The first questions finish the SI ladder below nano, pico, femto and atto, each one a thousand times smaller than the last. A prefix error of one step is a thousand-fold error in the result, so these small questions carry real weight.

Method quality comes next. The quiz asks what makes an analytical method reliable, and it gives two pairs of answers across two questions: specificity with accuracy, and precision with sensitivity. The coefficient of variation, MRI and NMR follow, each one an abbreviation that only makes sense when you know what it measures.

The second half turns to food itself. Rheometer geometries, large-strain deformations, apparent elastic properties, and image analysis for texture, appearance, shape, volume and mass estimation. Mealiness and wooliness in fruit both trace back to a lack of juiciness, and time-resolved diffuse reflectance spectroscopy, farinograph, mixograph, alveograph and the other wheat instruments close the set, with judgement sampling as the non-probability method to recognise.

Concepts you will need

Count the SI steps in threes: milli, micro, nano, pico, femto, atto, each one 10 to the power minus 3 further down. For methods, keep accuracy, precision, specificity and sensitivity as four separate words: accuracy is closeness to the true value, precision is repeatability, specificity is freedom from interference, and sensitivity is the smallest change the method can see.

How to use this quiz

You get 20 seconds per question and one attempt at each answer, so say the exponent before you look at the SI options, and say the method quality in plain words before you look at those options. A wrong answer here usually means two close words swapped, such as accuracy for precision, so re-pair each word with its plain meaning before retaking.

Other Food Analysis Topics – Part 5
Uncategorized

Choose how you want to play

Sound effects
🔈 Volume
Show explanations
🔊 Auto-read every question
Reading speed

Answer explanations

Worked through the quiz? Here is why each correct answer is correct: the concept behind it, in plain terms.

  1. What value does the SI prefix ‘pico’ stand for?
    1. 10⁻¹⁸
    2. 10⁻⁹
    3. 10⁻¹² (correct answer)
    4. 10⁻¹⁵

    Correct answer: 10⁻¹². The SI prefix 'pico' stands for 10^-12 — one trillionth, as in picogram. Atto is 10^-18, nano is 10^-9 and femto is 10^-15.
  2. What value does the SI prefix ‘femto’ stand for?
    1. 10⁻¹²
    2. 10⁻⁹
    3. 10⁻¹⁸
    4. 10⁻¹⁵ (correct answer)

    Correct answer: 10⁻¹⁵. The SI prefix 'femto' stands for 10^-15 — one quadrillionth. Pico is 10^-12, nano is 10^-9 and atto is 10^-18.
  3. What value does the SI prefix ‘atto’ stand for?
    1. 10⁻¹⁸ (correct answer)
    2. 10⁻¹⁵
    3. 10⁻¹²
    4. 10⁻⁹

    Correct answer: 10⁻¹⁸. The SI prefix 'atto' stands for 10^-18 — one quintillionth, the smallest of the listed prefixes. Femto is 10^-15, pico is 10^-12 and nano is 10^-9.
  4. An analytical method is reliable when it has which two qualities?
    1. Accuracy
    2. Both specificity and accuracy (correct answer)
    3. Specificity
    4. Neither

    Correct answer: Both specificity and accuracy. An analytical method is reliable when it has both specificity — it measures the intended analyte without interference — and accuracy — its results come close to the true value. One without the other is not enough; both specificity and accuracy are needed for reliability.
  5. Which two qualities underpin the reliability of an analytical method?
    1. Sensitivity
    2. Neither
    3. Precision
    4. Both precision and sensitivity (correct answer)

    Correct answer: Both precision and sensitivity. The reliability of an analytical method is underpinned by both precision — the repeatability of its results — and sensitivity — the ability to detect small amounts of the analyte. A method that cannot repeat its results or cannot see low levels cannot be relied on; both precision and sensitivity are needed.
  6. What does the abbreviation C.V. stand for?
    1. Coefficient of variable
    2. All of these
    3. Coefficient of vectors
    4. Coefficient of variation (correct answer)

    Correct answer: Coefficient of variation. C.V. stands for Coefficient of Variation — the standard deviation expressed as a percentage of the mean, the standard measure of relative variability. 'Coefficient of variable' and 'coefficient of vectors' are garbled versions of the name.
  7. What does MRI stand for?
    1. Molecular Resonance Imaging
    2. Magnetic Radioisotopic Imaging
    3. Magnetic Resonance Imaging (correct answer)
    4. Magnetic Radioisotopic Induction

    Correct answer: Magnetic Resonance Imaging. MRI stands for Magnetic Resonance Imaging — the medical imaging technique based on the magnetic resonance of hydrogen nuclei. The molecular and radioisotopic variants are not the standard name.
  8. Which of these are testing geometries for a dynamic rheometer?
    1. All of these (correct answer)
    2. Parallel plates
    3. Concentric cylinder
    4. Cone & plate

    Correct answer: All of these. A dynamic (rotational) rheometer uses all of these testing geometries: parallel plates for soft solids and gels, the concentric cylinder (cup-and-bob) for low-viscosity fluids, and cone-and-plate for a uniform shear field. All of these are testing geometries for a dynamic rheometer.
  9. Which deformations are used in large-strain methodology?
    1. Compression
    2. Tension
    3. All of these (correct answer)
    4. Torsion

    Correct answer: All of these. Large-strain methodology — the deformation regimes used in texture analysis — employs compression, tension and torsion: compressing a sample between plates, pulling it apart, or twisting it. All of these deformations are used.
  10. Which of these are apparent elastic properties?
    1. Young’s modulus
    2. Both of these (correct answer)
    3. Poisson’s ratio
    4. Neither

    Correct answer: Both of these. Apparent elastic properties include both Young's modulus — the ratio of stress to strain in extension — and Poisson's ratio — the ratio of transverse to axial strain. Both of these are apparent elastic properties of foods.
  11. Which food attributes can image analysis assess?
    1. Both texture and appearance (correct answer)
    2. Texture
    3. Appearance
    4. Neither

    Correct answer: Both texture and appearance. Image analysis assesses both texture and appearance: cameras and software quantify surface texture as well as appearance attributes such as colour, size and shape. Both texture and appearance are within its reach.
  12. What does the abbreviation NMR stand for?
    1. Neutral Molecular Resonance
    2. Nuclear Magnetic Resonance (correct answer)
    3. Nuclear Molecular Resonance
    4. Neutral Magnetic Resonance

    Correct answer: Nuclear Magnetic Resonance. NMR stands for Nuclear Magnetic Resonance — the spectroscopic technique based on the resonance of atomic nuclei in a magnetic field. The neutral and molecular variants are not the standard name.
  13. Mealiness in fruits comes from a lack of what?
    1. Viscosity
    2. Neither
    3. Juiciness (correct answer)
    4. Both of these

    Correct answer: Juiciness. Mealiness in fruits comes from a lack of juiciness: the cells separate instead of rupturing, so little juice is released when the fruit is bitten — the classic mealy apple or peach. Viscosity is not the missing attribute; juiciness is.
  14. Wooliness in fruits comes from a lack of what?
    1. Viscosity
    2. Neither
    3. Juiciness (correct answer)
    4. Both of these

    Correct answer: Juiciness. Wooliness in fruits comes from a lack of juiciness: a dry, woolly texture develops when the fruit fails to release juice normally, as in woolly peaches after cold storage. It is the absence of juiciness, not viscosity, that defines it.
  15. What can image analysis examine?
    1. Volume
    2. All of these (correct answer)
    3. Shape
    4. Mass estimation

    Correct answer: All of these. Image analysis can examine all of these: it measures volume from three-dimensional reconstructions, shape from outlines and contours, and estimates mass from size and density relationships. All of these can be examined by image analysis.
  16. What quality attributes can image analysis examine?
    1. Colour
    2. Texture
    3. All of these (correct answer)
    4. Mass

    Correct answer: All of these. Image analysis can examine all of these quality attributes: colour from pixel values, texture from surface patterns, and mass (estimated from dimensions). All of these are within its scope.
  17. What does the abbreviation TDRS stand for?
    1. Total diffuse reflectance spectroscopy
    2. Time-resolved diffuse reflectance spectroscopy (correct answer)
    3. Time diffuse reflectance spectroscopy
    4. Temperature diffuse reflectance spectroscopy

    Correct answer: Time-resolved diffuse reflectance spectroscopy. TDRS stands for Time-resolved diffuse reflectance spectroscopy — the optical technique that measures how light pulses spread through a sample over time to probe its internal structure. The total, time-only and temperature variants are garbled versions of the name.
  18. Which of these instruments are used in wheat analysis?
    1. Farinograph
    2. Mixograph
    3. All of these (correct answer)
    4. Consistograph

    Correct answer: All of these. Wheat analysis uses all of these instruments: the farinograph measures dough development and mixing tolerance, the mixograph does the same on small samples, and the consistograph measures dough consistency during mixing. All of these are used in wheat analysis.
  19. Which other instruments are used in wheat analysis?
    1. Alveograph
    2. Amylograph
    3. All of these (correct answer)
    4. Extensograph

    Correct answer: All of these. Wheat analysis also uses all of these: the alveograph measures dough bubble strength and extensibility, the amylograph measures starch gelatinization and pasting behaviour, and the extensograph measures dough resistance and extensibility. All of these are used in wheat analysis.
  20. Which of these is a non-probability sampling technique?
    1. Judgement sampling (correct answer)
    2. Stratified sampling
    3. Composite sampling
    4. Cluster sampling

    Correct answer: Judgement sampling. Judgement (purposive) sampling is a non-probability sampling technique: the sampler deliberately chooses units based on expertise rather than random selection. Stratified, composite and cluster sampling are probability-based designs; judgement sampling is the non-probability one.