Other Food Analysis Topics – Part 4
GIFSQ ID: ART-0848
What this quiz covers
Before a food result means anything, the sample has to be taken properly, prepared properly and measured with the right instrument. This quiz tests that groundwork: the geometries of a rheometer, the optics of a microscope and a polarimeter, the spot tests that catch added chemicals, and the sampling words that decide whether a lab result speaks for the whole lot.
Rheometry opens the quiz. Cup-and-bob, parallel-plate and cone-and-plate are all probe geometries of the rheometer, the instrument that measures how a food flows and deforms. The microscope is the instrument with an eye-piece, and polarimetry is the method that reads plane-polarised light and specific rotation, which depend on optical activity, concentration and path length.
The middle questions cover detection tests: glycerol and turmeric paper tests for boric acid, the Leach test for formaldehyde, and the ferric chloride test, which the quiz keys to salicylic acid, formaldehyde and benzoic acid together. Sampling then takes over: simple random, systematic and stratified sampling, composite and gross samples, lots, strata and test portions, and the mills and grinders that prepare a sample for analysis. The quiz closes with the SI prefixes mega, giga, micro and nano.
Concepts you will need
Link each geometry to its instrument before you read the options, and link each test to one target chemical. For sampling, keep the chain in order: population, lot, sample, test portion. A test portion is the small part that actually goes into the instrument, and it only represents the lot if every step before it was done right.
How to use this quiz
You get 20 seconds per question and one attempt at each answer, so name the instrument or the test first, then check the options. A wrong answer here usually means a geometry or a test attached to the wrong instrument, so re-pair each name with its instrument before retaking.
Choose how you want to play
Answer explanations
Worked through the quiz? Here is why each correct answer is correct: the concept behind it, in plain terms.
- The cup-and-bob geometry belongs to which instrument?
Correct answer: Rheometer: cup-and-bob is a measuring geometry of the rheometer, used to test flow in liquids and pastes. - Parallel-plate probes are used with which instrument?
Correct answer: Rheometer: parallel plates are a rheometer geometry for measuring viscosity and deformation. - Cone-and-plate probes are part of which instrument?
Correct answer: Rheometer: cone-and-plate is a rheometer geometry that gives a uniform shear rate across the sample. - Which instrument has an eye-piece?
Correct answer: Microscope: the microscope is viewed through an eye-piece, which magnifies the image for the observer. - Which of these is polarimetry connected with?
Correct answer: Both of these: polarimetry is connected with both specific rotation and plane-polarised light. - Which of these does polarimetry involve?
Correct answer: All of these: polarimetry involves optical activity, concentration and path length, all of which set the rotation read. - Which tests detect boric acid?
Correct answer: Both of these: the glycerol test and the turmeric paper test both detect boric acid. - What does the Leach test detect?
Correct answer: Formaldehyde: the Leach test is the named test for formaldehyde in foods. - What does the ferric chloride test detect?
Correct answer: All of these: the quiz keys the ferric chloride test to salicylic acid, formaldehyde and benzoic acid together. Note: in standard practice ferric chloride is best known as a phenol test, and it is most firmly linked to salicylic acid, so treat the formaldehyde and benzoic acid links as the quiz key, not as a general rule. - Which of these are types of sampling?
Correct answer: All of these: simple random, systematic random and stratified random sampling are all recognised sampling types. - Which of these are sampling terms: composite, gross sample or increment?
Correct answer: All of these: composite, gross sample and increment are all standard sampling terms. - Which of these are sampling terms: bulk sampling, lot or homogeneity?
Correct answer: All of these: bulk sampling, lot and homogeneity are all standard sampling terms. - Which of these are sampling terms: population or laboratory sample?
Correct answer: Both of these: population and laboratory sample are both standard sampling terms. - Which of these are sampling terms: segment, strata or sample?
Correct answer: All of these: segment, strata and sample are all standard sampling terms. - Which of these are sampling terms: test portion or subsample?
Correct answer: Both of these: test portion and subsample are both standard sampling terms for the part actually analysed. - Which of these are used in sample preparation?
Correct answer: All of these: the ball mill, ultracentrifugal mill and tissue grinder are all used to prepare samples for analysis. - What value does the SI prefix ‘mega’ stand for?
Correct answer: 10⁶: mega means one million, or 10 to the power 6. - What value does the SI prefix ‘giga’ stand for?
Correct answer: 10⁹: giga means one thousand million, or 10 to the power 9. - What value does the SI prefix ‘micro’ stand for?
Correct answer: 10⁻⁶: micro means one millionth, or 10 to the power minus 6. - What value does the SI prefix ‘nano’ stand for?
Correct answer: 10⁻⁹: nano means one thousand-millionth, or 10 to the power minus 9.