Hot air oven: wear insulated gloves when removing or placing samples in the heated oven. Stand to one side when opening the door.
1. Scope & Principle
Scope: Routine reference method for moisture content of cereals, pulses, flours, and cereal products.
🚫 Not applicable to malted foods.
Principle: Sample is dried at 130 ± 3 °C to constant mass. Loss in mass is expressed as percentage.
2. Equipment / Apparatus Checklist
Tick off each item as prepared:
Table 1: Equipment checklist for moisture determination.
3. Sample Preparation
Macaroni / Grains: Select representative portion, grind 300–500 g to pass No. 20 sieve, store in airtight container.
4. Method of Analysis Flowchart
Click checkboxes in sequence:
5. Calculation, Specifications & Output Report
Moisture (%) = (W1 minus W2) divided by (W1 minus W), times 100, where W is the mass of the empty dish, W1 is dish plus sample before drying, and W2 is dish plus sample after drying. All masses are in grams, weighed to 0.001 g.
Moisture Calculator
Standard & Testing Parameters
Laboratory test certificate and result summary
Moisture Determination Worksheet | GIFSQ SOP
| Sample Name / ID: | — |
| Testing Date & Time: | — |
| Standard Protocol: | Government Standard (Max 13.0%) |
| Drying Parameters: | 130 °C for 2 Hours |
| Parameter | Symbol | Measured Value |
|---|---|---|
| Mass of Empty Dish | W | — g |
| Dish + Sample Before Drying | W1 | — g |
| Dish + Sample After Drying | W2 | — g |
| Initial Sample Mass | W1 – W | — g |
_______________________
Tested By (Analyst)
_______________________
Approved By (QA Manager)
Frequently Asked Questions
What temperature and time does this moisture method use?
The sample is dried at 130 ± 3 °C to constant mass, with a target of 2 hours at 130 °C and a maximum moisture limit of 13.0% for the cereals and cereal products covered by this SOP.
How much sample do I weigh for the test?
Weigh about 5.0 g of sample into a pre-dried dish, and record the mass to 0.001 g. Grind a representative 300 to 500 g portion first so it passes a 1.0 mm (No. 20) sieve.
Why must the dish cool in a desiccator before the final weighing?
The dish must cool to room temperature (25 ± 3 °C) in a desiccator before the final weighing, so the dried sample does not pick up moisture from the air and change the result.
Does this method apply to malted foods?
No. The scope on this page states the method is not applicable to malted foods.
Conclusion
Moisture content decides how cereals store, mill and bake, and this oven-drying SOP gives a repeatable way to measure it: dry at 130 ± 3 °C to constant mass, weigh to 0.001 g, and report the loss as a percentage against the 13.0% limit. Keep the desiccator step and the re-dry to constant mass; skipping either one is the most common source of a wrong result. Next, read the guide to moisture analysis methods compared to see when oven drying is the wrong choice, and the water activity guide to see why moisture content alone does not prove a food is safe to store.
6. References
- Standard Moisture Determination Methodology & Quality Assurance SOP Guidelines
- AOAC International, Official Methods of Analysis, moisture method cited on this page as the AOAC reference for cereal moisture.
- IS 4333, cited on this page as the standard reference for this method.