Food Technology Loksewa – Sampling
GIFSQ ID: ART-1193
Test your knowledge with this free 20-question Sampling quiz from Food Quality Assurance & Quality Control — part…
What this quiz covers
This Loksewa set is about sampling, the step that decides whether any laboratory result means anything, and it opens with one word: representative. A representative sample accurately reflects the characteristics of the whole lot; without that, no test result can support an accept or reject decision. The set then teaches the ICMSF sampling plan language, the four letters n, c, m and M: n is the number of sample units drawn, c is the most units allowed to exceed the m limit, m is the limit between acceptable and marginally acceptable quality, and M is the limit above which the lot is unacceptable.
The middle questions sort the plan types and the sampling methods. A two-class plan has only acceptable and unacceptable outcomes, so it needs n, c and m; a three-class plan adds a marginally acceptable zone, so it needs all four. Random sampling gives every unit an equal chance, stratified sampling represents each sub-group of a non-uniform lot, and a composite sample mixes several increments into one sample for analysis. The practical questions follow the sample from the lot to the laboratory: aseptic collection in sterile containers, cool storage and prompt analysis, increments from different locations and depths in a bulk lot, quartering to reduce the combined sample, clear labelling with identity, date, lot and sampler, and coverage of different pallets, positions and production times in storage.
n, c, m and M: four letters, one plan
The four ICMSF letters are a small code, and the questions test whether you can read it. The letter n counts the sample units. The letter c counts how many of them may cross the m line. The letter m is the lower limit, the line between acceptable and marginally acceptable. The letter M is the upper limit, the line between marginal and defective, and any unit above M fails the lot outright. Two-class plans have no marginal zone, so they have no M; three-class plans have one, so they need all four letters. The stringency rule sits above the code: the higher the health risk and the more vulnerable the intended consumer, the stricter the plan must be.
How to use this quiz
Take the quiz cold first, then read the explanations below the player. Each answer gives the reason behind the key, with the numbers and definitions a food technologist is expected to know by heart.
Choose how you want to play
Answer explanations
Worked through the quiz? Here is why each correct answer is correct: the concept behind it, in plain terms.
- A representative sample is one that:
Correct answer: Accurately reflects the characteristics of the whole lot. A representative sample accurately reflects the characteristics of the whole lot , without representativeness, test results cannot be trusted for accept/reject decisions on the lot (ISO 7002 principles of sampling). - In ICMSF sampling plans, "n" denotes:
Correct answer: The number of sample units drawn from the lot. In ICMSF sampling plans, n is the number of sample units drawn from the lot (ICMSF, Microorganisms in Foods 2: Sampling for Microbiological Analysis). - In ICMSF sampling plans, "c" denotes:
Correct answer: The maximum allowable number of sample units exceeding the m limit. In ICMSF sampling plans, c is the maximum allowable number of sample units that may exceed the m limit while the lot is still accepted (ICMSF Microorganisms in Foods 2). - In ICMSF sampling plans, "m" denotes:
Correct answer: The microbiological limit separating acceptable from marginally acceptable quality. In ICMSF three-class plans, m is the microbiological limit that separates acceptable quality from marginally acceptable quality (ICMSF Microorganisms in Foods 2). - In a three-class ICMSF plan, "M" denotes:
Correct answer: The limit above which the lot is unacceptable, separating marginal from defective. M is the limit above which the lot is unacceptable , it separates marginally acceptable results from defective ones (ICMSF Microorganisms in Foods 2). - A two-class attributes sampling plan is defined by:
Correct answer: n, c and m. A two-class attributes plan has only acceptable/unacceptable outcomes, so it is defined by n (sample units), c (allowed exceedances) and m (the single limit) , no M is needed (ICMSF Microorganisms in Foods 2). - A three-class attributes sampling plan is defined by:
Correct answer: n, c, m and M. A three-class plan adds a marginally acceptable zone, so it needs the full set: n, c, m and the upper limit M (ICMSF Microorganisms in Foods 2). - Random sampling means:
Correct answer: Every unit in the lot has an equal chance of being selected. In random sampling, every unit in the lot has an equal chance of being selected, which removes sampler bias , the basis for valid statistical inference (Codex CXG 50-2004, General Guidelines on Sampling). - Stratified sampling is useful when:
Correct answer: The lot consists of distinct sub-groups that should each be represented. Stratified sampling divides the lot into distinct sub-groups (strata) and samples each one, so every sub-group is represented , the right approach when the lot is not uniform (Codex CXG 50-2004). - A composite sample is:
Correct answer: Several increments combined and mixed into one sample for analysis. A composite sample combines and mixes several increments into one sample for analysis, averaging out local variation across the lot (ISO 7002; Codex CXG 50-2004). - Increasing the sample size (n) in a sampling plan generally:
Correct answer: Increases confidence in the accept/reject decision. Increasing n tightens the operating characteristic curve of the plan, so the accept/reject decision becomes more discriminating and confidence in the outcome rises (sampling statistics; Codex CXG 50-2004). - Samples for microbiological testing must be collected:
Correct answer: Aseptically, in sterile containers, to avoid contamination. Microbiological samples must be collected aseptically in sterile containers , contamination from hands, air or dirty tools would inflate counts and invalidate the result (ICMSF sampling guidance). - After collection, microbiological samples should be:
Correct answer: Kept cool and analysed promptly to prevent changes in microbial numbers. Microbiological samples must be kept cool and analysed promptly, because microbes multiply or die off during warm delays, changing the numbers the laboratory measures (ICMSF). - The Codex General Guidelines on Sampling are published as:
Correct answer: CXG 50-2004. The Codex General Guidelines on Sampling are published as CXG 50-2004 (Codex Alimentarius). CXC 1-1969 is the General Principles of Food Hygiene, and CXS 193-1995 covers contaminants , different documents. - When sampling a bulk lot (e.g. grain in a silo), the correct approach is to:
Correct answer: Take increments from different locations and depths to represent the whole. A bulk lot such as grain in a silo is heterogeneous, so increments must be taken from different locations and depths to represent the whole (ISO 7002; Codex CXG 50-2004). - Sample increments are combined and then reduced to laboratory sample size by:
Correct answer: Mixing thoroughly and subdividing (e.g. quartering). The combined increments are mixed thoroughly and subdivided , classically by quartering , to reduce them to laboratory sample size while keeping the sub-sample representative (ISO 7002). - Every sample container must be:
Correct answer: Clearly labelled with identity, date, lot and sampler details. Every sample container must be clearly labelled with the sample identity, date, lot and sampler details , an unlabelled sample is untraceable and useless for decisions (ISO 7002). - A sampling plan's stringency (strictness) should be related to:
Correct answer: The health risk posed by the hazard and the intended use of the food. A sampling plan's stringency must reflect the health risk posed by the hazard and the intended use of the food , high-risk hazards, such as pathogens in ready-to-eat foods, demand the strictest plans (ICMSF; Codex CXG 50-2004). - Reference (retained) samples from each lot are kept so that:
Correct answer: Results can be verified later if disputes or complaints arise. Retained (reference) samples from each lot are kept so that results can be re-verified later if a dispute or complaint arises , they are the physical evidence behind the lot decision (standard QC retention practice). - Sampling of packaged foods from a lot in storage should cover:
Correct answer: Different pallets, positions and production times within the lot. Sampling packaged foods from a lot in storage must cover different pallets, positions and production times within the lot, because variation hides exactly where a front-pallet-only sample would miss it (ISO 7002; Codex CXG 50-2004).