SOP: Total Plate Count by Pour Plate Method

GIFSQ ID: SOP-0931

Purpose

The aerobic plate count (total plate count) estimates the number of viable mesophilic aerobic bacteria in a food sample. It serves as a general hygiene indicator: high counts point to temperature abuse, poor sanitation, or contaminated raw materials, while trends over time show whether a process stays under control. This SOP follows the pour plate approach of AOAC 966.23 and ISO 4833-1, sample dilutions are mixed with molten plate count agar, incubated, and colonies are counted within the valid range.

Scope

This procedure applies to dairy products, cooked and raw meats, poultry, seafood, bakery products, spices, dried mixes, and ready-to-eat foods. It does not apply to fermented products where high lactic-acid populations are normal and expected, nor to samples requiring specific pathogen testing: use the relevant selective method for that. Report results as colony-forming units per gram (CFU/g) or per millilitre (CFU/mL).

Interactive SOP: work through it here

The full procedure below is interactive: step-by-step method, a working CFU calculator, and a result worksheet you can fill in and print. For printing or presenting, open it in a full tab.

Open the interactive SOP in a full tab · best for printing and for the calculator on small screens.

Method parameters at a glance

ParameterRequirement
Method basisAOAC 966.23 and ISO 4833-1 pour plate technique (confirm the current edition of the method your laboratory has adopted)
MediumPlate count agar (PCA), sterilised
DiluentBuffered peptone water (BPW) or the diluent specified in the adopted method
Incubation30 ± 1 °C for 72 ± 3 h (ISO 4833-1). 48 h at 35 °C is an accepted equivalent under some compendial methods: record which condition was used.
Countable rangeCount plates containing between 30 and 300 colonies
ReportingColony-forming units per gram (CFU/g) or per millilitre (CFU/mL)