Physical Analysis
SOP: Testing the Difference Between Two Independent Lot Means by the t-Test
Principle The t-test compares the means of two groups of observations and assesses whether the difference between them can reasonably be ascribed to chance. The null hypothesis states that there is no real difference between the two lot means; the difference is divided by the standard error of the difference, and the resulting t-value is […]
SOP: Testing the Mean Against a Specified Value by the t-Test
Principle The t-test is used to judge whether the mean of the lot from which a sample has been drawn differs significantly from a specified value. The null hypothesis states that there is no real difference between the lot mean and the specified value; the calculated t-value is compared with tabulated t-values at the 5% […]
SOP: Fitting the Poisson Distribution to Rot Counts and Testing Goodness of Fit
Purpose To fit observed counts (for example, rot counts or insect fragments per sample) to the Poisson distribution and to test the goodness of fit with the chi-square test, so the laboratory can judge whether the samples were drawn at random. Scope This method applies when the sample size of a lot is very large […]
SOP: Testing Significance in Triangle Tests Using the Binomial Distribution
Principle In a triangle test each trial presents three samples, of which one is different and two are the same, so the chance of picking the odd sample correctly by guessing is 1/3. The binomial distribution gives the probability that the odd sample is picked correctly exactly x times in m trials; comparing the observed […]
SOP: Computation of Frequency Distribution with Median, Mode, Range and Grouped Standard Deviation
Principle Large sets of numerical data: for example, the weights of individual fruits in a lot: are condensed by arranging them in groups (class intervals) and counting how many observations fall in each group. The relation between the class intervals and their frequencies is the frequency distribution, which shows the pattern of the data. The […]
SOP: Computation of Mean, Variance, Standard Deviation, Standard Error and Coefficient of Variation
Principle A sample drawn from a lot is measured, and the quantities computed from the sample data: the statistics: are used to describe the lot. The arithmetic mean locates the centre of the data, the variance and its square root, the standard deviation, measure the scatter about the mean, the standard error of the mean […]
SOP: Polarimetric Examination of Vinegar
Principle The optical rotation of a vinegar, measured in a polarimeter tube, distinguishes the types: malt and molasses vinegars are dextro-rotatory, cider and grape vinegars are laevo-rotatory, and spirit vinegar has no optical activity. Turbid or dark samples are clarified before reading, and a right-handed reading on a cider vinegar indicates adulteration. Apparatus required Polarimeter […]
SOP: Determination of Bulk Density of Dehydrated Fruits and Vegetables
Principle Bulk density is the weight of product held in a unit volume; it is measured because it matters in the packaging of the product. The weight of sample filling a cylinder of exactly 625 ml water capacity is weighed, and the bulk density in lb/cu ft is obtained by dividing the weight in grams […]
SOP: Determination of Colour in Tomato Products by Solvent Extraction
Principle Red colour is one of the most important quality attributes of tomato products. Of the tomato’s pigments, lycopene predominates, accounting for approximately 83% of the pigments present. In this rapid method, the pigments are extracted from the sample with benzene, and the colour is measured by the absorbance of the extract at 485 nm. […]
SOP: Determination of Specific Gravity of Tomato Products
Principle When the procedure is followed properly, the specific gravity method gives an accurate and quite rapid estimate of total solids. The specific gravity of whole juice, pulp or filtrate bears a reasonably close relationship to total solids, which are ascertained by referring to the tomato pulp and paste tables. The specific gravity bottle procedure […]
SOP: Determination of Gel Strength with the Tarr–Baker Gelometer
Principle The breaking strength of the set jelly is measured as the water pressure required to force a weighted piston through the gel. The pressure at which the jelly breaks, read on a water manometer, is used to determine the grade of the pectin by reference to a nomogram relating breaking strength to the quantity […]
SOP: Test for Gelation in Citrus Juice Concentrates
Principle Frozen concentrated juices gel when pectin concentration, sugar content, residual pectinesterase activity and pH combine unfavourably; freeze damage to the fruit, pulp content, pulp-and-juice finisher pressures and processing temperatures also affect it. The test incubates the concentrate under controlled conditions and classifies the degree of gelation by the flow behaviour of the thawed product. […]
SOP: Determination of the Degree of Concentration of Juice Concentrates
Principle Concentrates are described as 4-, 5- or 6-fold, meaning one volume of concentrate dilutes to 4, 5 or 6 volumes of juice. The fold of concentration is assessed from the specific gravity or the refractive index. The specific gravity of the concentrate itself cannot be measured directly (it tends to occlude air bubbles), so […]
SOP: Determination of Suspended Solids by Centrifugation
Principle The suspended solids of citrus juices (fine pieces of juice sacs, membrane and other structural components: also called insoluble solids, centrifuge solids, bottom pulp or sinking pulp) are separated by centrifuging the juice in graduated long-cone tubes. The reading at the top of the pulp layer, doubled, gives the percentage of free and suspended […]
SOP: Determination of Screened Pulp
Principle Screened pulp is the coarser pulp material retained on a standard 20-mesh screen; it consists largely of juice-sac material provided by the cut-back juice. The average screened pulp of Florida citrus concentrates is of the order of 1%. Apparatus required 20-mesh screen (12.7 cm diameter and 7.0 cm deep) made of woven stainless wire […]
SOP: Measurement of Carbon Dioxide in Bottled Beverages
Principle The degree of carbonation is measured as the equilibrium head-space pressure of the sealed bottle at a known temperature, read on a pressure gauge driven through the crown cork. The gauge reading and the beverage temperature are converted to gas volumes using Table 28-14. The beverage industry measures carbonation in “volumes”: the amount of […]
SOP: Determination of Apparent Viscosity by Capillary Viscometer
Principle Consistency, often related to mouth feel, is influenced by the amount, size and shape of insoluble solids and the viscosity of the serum, and is an important quality factor. The apparent viscosity of unclarified juices is measured with the Lamb and Lewis capillary viscometer (adopted as the official method and by the Codex Alimentarius […]
SOP: Colour Grading of Juices
Principle Good juice keeps the colour of its fruit variety: natural-looking, without browning or any off-colour. Orange juice colour is graded against prepared USDA colour standards: the juice sample is matched visually against a series of standard tubes under standardized lighting. Apparatus required USDA orange-juice colour standards: 6 tubes OJ 1 (deepest coloured standard) to […]
SOP: Determination of Specific Gravity by Specific Gravity Bottle
Principle Unfermented fruit and vegetable juices containing only traces of alcohol or essential oil always show a specific gravity above 1.0; the lower the soluble solids, the smaller the specific gravity, and sweet juices have higher specific gravity. The specific-gravity-bottle method is the reference method, giving an accuracy of 0.001. Hydrometers may be used for […]
SOP: Determination of Alcohol-Insoluble Solids in Frozen Peas
Principle The alcohol-insoluble solids (AIS) content of peas reflects maturity and serves as a quality factor for quick frozen peas. The prepared paste is boiled with slightly diluted alcohol; the solids are washed with alcohol until the filtrate runs clear, then dried and weighed. The residue is chiefly insoluble carbohydrate (starch) and protein. The Codex […]
SOP: Determination of Fibrous Material in Frozen French Beans
Principle The fibre content of beans increases with maturity and is a good index of quality. The thawed beans are washed free of covering material, boiled, deseeded, boiled in caustic solution, macerated, sieved and washed free of alkali; the dried fibrous residue is weighed and expressed as a percentage of the sample. Apparatus required Mixer: […]
SOP: Determination of Specific Gravity of Frozen Vegetables
Principle Specific gravity is used to determine the maturity level of frozen sweet corn and peas: the weight of the sample is first determined in air and then in a liquid, and the specific gravity is calculated from the two weights. Apparatus required One-pan balance weighing to 0.1 g, with a hook under the pan […]
SOP: Determination of Drained Weight of Frozen Fruits and Vegetables
Principle The frozen package is thawed in a water bath under standardised conditions, the contents are drained on a standard sieve for a fixed time, and the drained weight is expressed as a percentage of the net weight of the package. Apparatus required Water bath maintained at 30 ± 1°C, kept agitated Number 8 sieve […]
SOP: Thawing of Quick Frozen Fruits and Vegetables
Principle Quick frozen fruits and vegetables are thawed by a standardised procedure: in air or in water: chosen so that the product thaws rapidly without altering or degrading its characteristics, and without leaching soluble solids from cut surfaces. Procedure Use the entire package; for bulk products use 1–2 kg of a representative sample ↓ Thaw […]